Search
16 result(s) for Read
-
OPC-10000-2 – OPC Unified Architecture - Part 2: Security ModelService calls until the Server has completed any user change. For Services like Read or Browse , the Server needs to ensure that any Service call that were issued under
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.58 AccessLevelExTyperepresent the atomicity of a Variable . In general Atomicity is expected of OPC UA read and write operations. These Fields are used by systems, in particular hard-realtime controllers, which ... TimestampWrite 6 See 8.57 . Reserved 7 See 8.57 . NonatomicRead 8 Indicates non-atomicity for Read access (0 means that atomicity is assured). NonatomicWrite 9 Indicates non-atomicity for Write access
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.3.1 DescriptionDescription The Session -less Service invocation is introduced for Services, such as Read , Write or Call , that do not require any caller specific state information. It is accessible through ... ensure consistency of namespace arrays between Client and Server . The UrisVersion is first read from the Server together with the NamespaceArray and ServerArray . This reduces the overhead per call
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesService failed. The additional parameters should include the details of the request. The Read and HistoryRead Services may generate audit entries and audit Events for failed Service invocations. These Services
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.6.2.4.5.4 Hotachieve load balancing; this means that Clients should issue Service requests such as Browse , Read , Write to the Server with the highest ServiceLevel. Subscription related activities will need
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.39 TimestampsToReturnenumeration that specifies the Timestamp Attributes to be transmitted for MonitoredItems or Nodes in Read and HistoryRead . The values of this parameter are defined in Table 180 . Table 180 - TimestampsToReturn
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.3.4 Arrayselement in the array shall be the type name. For example, the Read service takes an array of ReadValueIds. The XML schema would look like: <xs:complexType name
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsthis ConditionVariable . It shall be the same time that would be returned from the Read Service inside the DataValue structure for the ConditionVariable Value Attribute
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.3 OpenWithMasksOpenWithMasks The OpenWithMasks Method allows a Client to read only a portion of the TrustList. This Method can only be used to read the TrustList . After calling this Method ... Client calls Read one or more times to get the TrustList . If the Server is able to detect out of band changes to theTrustList before the Client calls the Close
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.1 PubSubConfigurationTypewith the Server . The FileType functionality is used instead of passing the PubSubConfiguration2DataType to read and write Methods to overcome potential limitations of communication buffers for OPC UA Service calls ... able to transfer large configurations. The Open Method shall not support modes other than Read (0x01), Write + EraseExisting (0x06) and Read + Write (0x03). When a Client opens the file
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubServer is organized in the Server Address Space . Services like Read , Write and Browse are available with a request/response pattern used by OPC UA Clients to access information provided
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.2.4 ReadRead Read is used to read a part of the file starting from the current file position. The file position is advanced by the number of bytes read. Signature Read ... InvalidState See OPC 10000-4 for a general description. File was not opened for read access. Table 4 specifies the AddressSpace representation for the Read Method . Table 4 - Read Method
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.4.3 GenerateFileForReadGenerateFileForRead GenerateFileForRead is used to start the read file transaction. A successful call of this Method creates a temporary FileType Object with the file content and returns the NodeId ... opened TransferFile . The fileHandle can be used to access the TransferFile Methods Read and Close . completionStateMachine If the creation of the file is completed asynchronous, the parameter returns the NodeId
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationClient / Server scenario, Clients can obtain the metadata initially by separate browse and read operations. Metadata changes can be notified using ModelChange and SemanticChange Events . When using Subscriptions , the Server ... affected DataSet . Considering possible application failure due to usage of outdated metadata, invoking the Read Service to obtain the Value of a merged compact representation not containing the associated metadata
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model13.1 Overviewinformation. Resolving Node information may require using View Services ( Browse , TranslateBrowsePathsToNodeIds ) and Attribute Services ( Read ). The details related to an application's configuration are provided in a Descriptor
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.2 Open Methodspecification does impose security restrictions. The Open Method shall not support modes other than Read (0x01) and Write + EraseExisting (0x06). The Client shall be authorised to modify the configuration