32 result(s) for ParameterSet
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicesmodel for elements in a device or component topology. Among others, it introduces FunctionalGroups , ParameterSet , and MethodSet . Figure 2 shows the TopologyElementType . It is formally defined in Table 12 . Figure ... FunctionalGroupType O 0:HasComponent Object 1:Lock 1:LockingServicesType O 0:HasComponent Object 1:ParameterSet 0:BaseObjectType O 0:HasComponent Object 1:MethodSet 0:BaseObjectType O Conformance Units DI Information
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices5.4 ConnectionPointconnected Device . These Parameters can be components of the NetworkAddress FunctionalGroup , of the ParameterSet , or another Object . <ProfileIdentifier> identifies the Communication Profile that this ConnectionPoint supports. ProtocolType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.3.1 Generalonly in either the online or the offline element. A Parameter in the offline ParameterSet and its corresponding counterpart in the online ParameterSet shall have the same BrowseName . Their NodeIds
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-34.2.3.4 Introduction to OPC UA Devicesshows an example for a temperature controller represented as Device Object . The component ParameterSet contains all Variables describing the Device . The component MethodSet contains all Methods provided by the Device
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.1.1 Overviewvendor or user specific configurations. A concrete Ctrl Configuration type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.2.1 Overviewvendor or user specific resources. A concrete Ctrl Resource type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>12.2.2 TopologyElementTypewith IFunction.FunctionInfo and IData.DataInfo is mapped into the MethodSet and to the ParameterSet . For both types of information (Commands and Parameters) also references in FunctionalGroup nodes are created, so that ... TopologyType information Table 62 - TopologyElementType mapping OPC FDT BrowseName Interface Method Data member Description ParameterSet IInstanceData / IDeviceData <>GetDataInfo DataInfo.DeviceDataItems DeviceDataItems is a hierarchical list of data items that
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>12.2.3 FunctionalGroupTypeFunctionalGroupType The FunctionalGroupType is used to organize Parameters and Methods (which are defined in ParameterSet and MethodSet ) in a user-friendly way (see Table 63 ). FunctionalGroups may be organized hierarchically
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>device are defined in separate areas of the OPC UA Information model (i.e. ParameterSet and MethodSet ), they are organized by functional groups into a concise representation, which may be structured ... hierarchy. This means, that the data of the IData interfaces are mapped to the ParameterSet node in the OPC UA Information model and the command functions from IFunction interface
-
OPC-30100 – OPC UA for SERCOS Devices5.3 SercosDeviceTypeProperties of the DeviceType defined in OPC UA for Devices companion specification. HasComponent Object ParameterSet FunctionalGroupType Mandatory HasComponent Object ProfileSet FunctionalGroupType Mandatory HasComponent Object ClassSet FunctionalGroupType Mandatory HasComponent Object FunctionGroupSet ... unique device ID managed by the vendor, that indentifies the component number. ParameterSet is inherited from TopologyElementType and mandatory for SercosDeviceType instances. ProfileSet includes all Sercos Profile instances that
-
OPC-30100 – OPC UA for SERCOS DevicesParameterType All the SercosParameterType instances of each device are referenced as component from the ParameterSet Object (BaseObjectType) (defined in OPC UA specification for devices). Every Sercos Parameter consists of elements
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture6.2.1 GeneralPOWERLINK Controlled Node . Figure 16 shows a part of the PowerlinkConnectionPointType . The Object ParameterSet contains the POWERLINK Objects, modelled as defined in 5.2 . In addition to these Variables, this specification ... defined by the concepts of OPC 10000-100 the Parameters ( Variables ) of the ParameterSet and Methods of the MethodSet are organised in FunctionalGroups where they are referenced by Organize-References
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.1.2 OverviewTypeDefinition Modelling Rule Subtype of TopologyElementType defined in OPC 10000-100 . HasComponent Object 2:ParameterSet BaseObjectType Mandatory HasComponent Object 2:MethodSet BaseObjectType Mandatory HasComponent Object 2:Identification FunctionalGroupType Mandatory HasComponent ... directly or indirectly from the TopologyElementType defined in OPC 10000-100 . The optional Object ParameterSet is used to reference all Parameters and shall be provided. Therefore, the ObjectType overrides
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.5.2 OverviewTypeDefinition Modelling Rule Subtype of TopologyElementType defined in OPC 10000-100 . HasComponent Object 2:ParameterSet BaseObjectType Mandatory HasComponent Object 2:MethodSet BaseObjectType Mandatory HasComponent Object 2:Identification FunctionalGroupType Mandatory HasComponent ... directly or indirectly from the TopologyElementType defined in OPC 10000-100. The optional Object ParameterSet is used to reference all Parameters and shall be provided. Therefore, the ObjectType overrides
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.6.2 OverviewTypeDefinition Modelling Rule Subtype of TopologyElementType defined in OPC 10000-100 . HasComponent Object 2:ParameterSet BaseObjectType Mandatory HasComponent Object 2:MethodSet BaseObjectType Mandatory HasProperty Variable DeviceConfigurationDisabled Boolean PropertyType Mandatory HasComponent ... directly or indirectly from the TopologyElementType defined in OPC 10000-100. The optional Object ParameterSet is used to reference all Parameters and shall be provided. Therefore, the ObjectType overrides
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)5.2.1.1 CsppMachineType ObjectTypeModellingRule Details Subtype of the DeviceType defined in OPC 10000-100 HasComponent Object 1:ParameterSet - BaseObjectType Mandatory 5.2.1.2 HasComponent Object <CommIfSection> - FunctionalGroup Type MandatoryPlaceholder 5.2.1.3 ModellingRule ... ParameterSet Object is Optional in the source of the inheritance but that of the CsppMachineType ObjectType should be Mandatory. The definition of the ParameterSet Object itself is overridden. For details
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)5.2.1.2 ParameterSet ObjectParameterSet Object The ParameterSet Object takes a role to organize machine information held by the machine Object . Table 6‑2 shows the definition of the ParameterSet Object . Table ... Definition for ParameterSet Object Attribute Value BrowseName 1:ParameterSet IsAbstract False References NodeClass BrowseName DataType TypeDefinition ModellingRule Details HasTypeDefinition ObjectType 0:BaseObjectType HasComponent Variable <VariableName> (Any) DataItemType OptionalPlaceholder
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.1 Basic policypart and COMM_IF_CONFIGURATION part are mapped to each DataVariable referred to from ParameterSet Object of CSP+ machine ObjectType by using HasComponent Reference . The DataVariable s above are grouped
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.6.2 CSPP elementpart and COMM_IF_CONFIGURATION part are mapped to each DataVariable referred to from ParameterSet Object of CSP+ machine ObjectType by using HasComponent Reference . The VariableType of each DataVariable
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical IntegrationFolderType O 0:HasComponent Object ProtectiveStopFunctions 0:FolderType O 0:HasComponent Object 2:ParameterSet 0:BaseObjectType M 0:HasProperty Variable 2:ComponentName 0:LocalizedText 0:PropertyType O Conformance Units ... EmergencyStopFunctionIdentifier> EmergencyStopFunctionType MP ProtectiveStopFunctions 0:HasComponent Object <ProtectiveStopFunctionIdentifier> ProtectiveStopFunctionType MP 2:ParameterSet 0:HasComponent Variable OperationalMode OperationalModeEnumeration 0:BaseDataVariableType M 2:ParameterSet 0:HasComponent Variable EmergencyStop
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.18.2 ControllerType definitionFolderType M 0:HasComponent Object TaskControls 0:FolderType M 0:HasComponent Object 2:ParameterSet 0:BaseObjectType O HasSafetyStates Object <SafetyStatesIdentifier> SafetyStateType OP 0:HasComponent Object Programs 0:FileDirectoryType ... SoftwareType MP TaskControls 0:HasComponent Object <TaskControlIdentifier> TaskControlType MP 2:ParameterSet 0:HasComponent Variable TotalPowerOnTime 0:DurationString 0:BaseDataVariableType O 2:ParameterSet 0:HasComponent Variable StartUpTime 0:DateTime
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.21.2 TaskControlType definitionHasProperty Variable 2:ComponentName 0:LocalizedText 0:PropertyType M 0:HasComponent Object 2:ParameterSet 0:BaseObjectType M Controls Object <MotionDeviceIdentifier> MotionDeviceType OP 0:HasAddIn Object TaskControlOperation TaskControlOperationType ... Table 101 - TaskControlType Additional Subcomponents Source Path Reference NodeClass BrowseName DataType TypeDefinition Others 2:ParameterSet 0:HasComponent Variable TaskProgramName 0:String 0:BaseDataVariableType M 2:ParameterSet 0:HasComponent Variable TaskProgramLoaded
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integrationkind of motion device shall be described with the Property MotionDeviceCategory of the ParameterSet of the MotionDeviceType by the MotionDeviceCategoryEnumeration, which is based on definitions
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices Systeminheriting the InstanceDeclarations of that Node. 0:HasComponent Object 2:ParameterSet 0:BaseObjectType M 0:HasComponent Object ProtectiveFunctions 0:FolderType O 0:HasAddIn Object 2:Identification 4:MachineIdentificationType ... HasComponent Object 2:Configuration 2:FunctionalGroupType O Conformance Units Cranes Base Info CraneMotionDeviceSystemType ParameterSet contains all the variables of the CraneMotionDeviceSystemType. variables are also referenced by an Organizes from either
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System7.2.1 Overviewcurrent state of the crane component (motion device). This is read-only, online data. ParameterSet contains all the variables of the CraneMotionDeviceSystemType. Variables are also referenced by an Organizes from ... subcomponents of a CraneMotionDevice . Note: If possible each of the values given in 2:ParameterSet should be instantiated and referenced again from the Operational FunctionalGroup. CraneMotionDeviceCategory property describes which category
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices Systemthat Node. 0:HasComponent Object 2:Operational 2:FunctionalGroupType O 0:HasComponent Object 2:ParameterSet 0:BaseObjectType M 0:HasAddIn Object 2:Identification 4:MachineryComponentIdentificationType O Conformance Units Cranes Base ... brake. It is specified in OPC 10000-100 and OPC 40001-1. ParameterSet contains all the variables of the BrakeType. Variables are also referenced by an Organizes from Operational FunctionalGroup
-
OPC-40561-2 – OPC UA for Mining - Extraction - Part 2: Shearer Loader7.1.1 OverviewMiningEquipmentType as shown in Figure 2 . Importantly, it contains a MethodSet and ParameterSet to monitor and control all relevant parameters of the equipment. Figure 2 - Overview ShearerLoaderType
-
OPC-40561-2 – OPC UA for Mining - Extraction - Part 2: Shearer Loader7.2.1 Overviewwithin the MiningEquipmentType as shown in Figure 3 . Importantly, it is composed of a ParameterSet Object instance declaration to cover all relevant parameters of the equipment. Figure 3 - ShearerLoaderDrumType Overview
-
OPC-40564-2 – OPC UA for Mining - Mineral Processing - Part 2: Rock Crusher7.2.1 OverviewMiningEquipmentType as defined in Figure 3 . It consists also of a MethodSet and a ParameterSet to cover all relevant aspects of the equipment. Figure 3 - Overview RockCrusherControlType
-
OPC-40565-2 – OPC UA for Mining - Development Support - Part 2: Roof Support System6.1.1 Overviewtype of MiningEquipmentType as shown in Figure 1 . Importantly, it is composed of a ParameterSet to monitor all relevant parameters of the equipment
-
OPC-40565-3 – OPC UA for Mining - Development - Part 3: Dozer6.1.1 OverviewMiningEquipmentType as shown in Figure 1 . Importantly, it is composed of a ParameterSet and a MethodSet to monitor and control all relevant aspects of the equipment. Figure 1 - Overview DozerType
-
OPC-40567-2 – OPC UA for Mining - PELO Services - Part 2: Face Alignment System6.1.1 OverviewMiningEquipmentType as shown in Figure 1 . Importantly, it is composed of a ParameterSet to monitor all relevant aspects of the equipment. Figure 1 - Overview FaceAlignmentSystemType