Search
17 result(s) for Maintenance
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical Interface3.2.3 MaintenanceMaintenance action for the achievement of machine-preserving measures
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services6.6.2.4.2 ServiceLeveldefined in Table 105 . Table 105 - ServiceLevel ranges Sub-range Name Description 0-0 Maintenance The Failed Server is in maintenance sub-range. Therefore, new Clients shall not connect ... additional information. A Server that has been set to Maintenance is typically undergoing some maintenance or updates. The main goal for the Maintenance ServiceLevel is to ensure that Clients
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Servicesdone through a complete shutdown or by setting the ServiceLevel of the Server to Maintenance sub-range. This can be done through a Server specific configuration tool or through
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsstates. It supports multiple transitions between Operating, StartingUp, ShuttingDown, Shutdown, OutOfService and Maintenance. The state machine is illustrated in Figure F.2 and formally defined in Table F.1 . Figure F.2 - SystemStateStateMachineType ... HasComponent Object StartingUp StateType HasComponent Object Shutdown StateType HasComponent Object OutOfService StateType HasComponent Object Maintenance StateType HasComponent Object ShutdownToOperating TransitionType HasComponent Object OperatingToShutdown TransitionType HasComponent Object ShuttingDownToShutdown TransitionType HasComponent Object
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.2.3 OverviewHasComponent Object 2:ParameterSet BaseObjectType Mandatory Organizes Object Specialist FunctionalGroupType Mandatory Organizes Object Maintenance FunctionalGroupType Mandatory Organizes Object Observer FunctionalGroupType Mandatory HasComponent Object IODDInformation FolderType - HasComponent Object DeviceVariants FolderType - HasComponent ... Specialist groups all menus of the SpecialistRoleMenuSet defined in an IODD. The mandatory Object Maintenance groups all menus of the MaintenanceRoleMenuSet defined in an IODD. The mandatory Object Observer groups
-
OPC-30140 – OPC UA for PROFINET6.3.4.1 PnDiagnosisAlarmTypeHasProperty Variable Type PnChannelTypeEnumeration PropertyType Mandatory HasProperty Variable Accumulative PnChannelAccumulativeEnumeration PropertyType Mandatory HasProperty Variable Maintenance PnChannelMaintenanceEnumeration PropertyType Optional HasProperty Variable Specifier PnChannelSpecifierEnumeration PropertyType Mandatory HasProperty Variable Direction PnChannelDirectionEnumeration PropertyType Mandatory ... active alarm the Severity variable of the Event must be dependent on the Maintenance and the QualifiedChannelQualifier variables. The Severity is divided into the 4 categories shown in the following
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelHasProperty Variable Accumulative GsdGenChannelAccumulativeEnumeration 0:PropertyType O, RO 0:HasProperty Variable Maintenance GsdGenChannelMaintenanceEnumeration 0:PropertyType O, RO 0:HasProperty Variable Specifier GsdGenChannelSpecifierEnumeration 0:PropertyType M, RO 0:HasProperty Variable Direction ... active alarm the Severity variable of the Event must be dependent on the Maintenance and the QualifiedChannelQualifier variables. The Severity is divided into the 4 categories shown in the following
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives7.1 DriveAxisTypeCharacteristicsMotorAndControl 0:FolderType O 0:HasComponent Object VelocityProfile 0:FolderType M 0:HasComponent Object Maintenance 0:FolderType M 0:GeneratesEvent ObjectType DiagnosisAlarmType 0:HasComponent Object Logbook 3:LogbookType O Conformance ... HasComponent Variable BrakeStatus 0:Byte 0:MultiStateDiscreteType O, RO Applied from 2:IOperationCounterType Interface: Maintenance 0:HasProperty Variable 2:PowerOnDuration 0:Duration 0:PropertyType O, RO Maintenance 0:HasProperty Variable
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsString 0:PropertyType O 0:HasComponent Object DeviceState LADSDeviceStateMachineType M 0:HasComponent Object Maintenance MaintenanceSetType O 0:Organizes Object 4:MachineryBuildingBlocks 0:FolderType O 0:HasAddIn Object 4:MachineryItemState ... more information). DeviceState StateMachine that controls and represents the Device 's current state. Maintenance is a set containing all maintenance tasks of a Device. The MachineryBuildingBlocks folder contains all machinery
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsHasAddIn Object Components LADSComponentsType O 0:HasAddIn Object 2:Identification M 0:HasComponent Object Maintenance MaintenanceSetType O 0:HasProperty Variable 3:OperationalLocation 0:String 0:PropertyType O 0:HasProperty Variable ... OperationCounters interface and lifetime variables (see OPC 10000-100 for more information). Maintenance is a set containing all maintenance tasks of a Device. The MachineryBuildingBlocks folder contains all machinery building
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.1.10.1 OverviewOverview The MaintenanceTaskType shall be used to implement instances of maintenance tasks applicable at both the Device and Component levels. Maintenance tasks include activities such as periodic maintenance, cleaning, calibration ... validation. Maintenance tasks for a Device shall be grouped under the Maintenance functional group present in the LADSDeviceType . The MaintenanceTaskType is formally defined in Table 51 . Note: All existing Properties
-
OPC-40001-1 – OPC UA for Machinery - Part 1: Basic Building BlocksDefaultInstanceBrowseName 0:QualifiedName 0:PropertyType - 0:HasComponent Object None - 0:StateType - 0:HasComponent Object Maintenance - 0:StateType - 0:HasComponent Object Processing - 0:StateType - 0:HasComponent Object Setup - 0:StateType ... None State represents that there is currently no MachineryOperationMode available for the MachineryItem . The Maintenance State represents that the MachineryItem is set into maintenance mode with the intention to carry
-
OPC-40082-6 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 6: Granulate Drying DevicesMaintenanceInformationType definition The MaintenanceInformationType provides information about all maintenance activities related to the granulate dryer and is formally defined in Table 35 . Each instance of the <Maintenance ... placeholder represents a maintenance activity category (examples: lubrication, inspection…). Figure 6 - MaintenanceInformationType overview Table 35 - MaintenanceInformationType Definition Attribute Value BrowseName MaintenanceInformationType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other
-
OPC-40084-1 – OPC UA interfaces for plastics and rubber machinery - Extrusion - Part 1: General Type DefinitionsB.2 Statusversion 1.01 and the new ones in version 2.0. For example, MALFUNCTION and MAINTENANCE which are separate states in version 1.01 can occur at the same time with the MachineryItemState ... OutOfService and MachineryOperationMode Maintenance when there is an error during maintenance. Table 26 - Comparison of machine status in v1.01 and v2.0 Version 1.01 ExtrusionDeviceType Status Version 2.00 Identification Name Value
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: Basepurpose of this interface is to provide the common information (Example: Identification, Health, Maintenance, etc.) of all the assets in a standardized way. This interface has a standard MachineryItemIdentificationType ... MachineryOperationCounterType O 0:HasAddIn Object 4:LifetimeCounters 4:MachineryLifetimeCounterType O 0:HasComponent Object 2:Maintenance 2:FunctionalGroupType O 0:HasComponent Object Parameters 0:FolderType O 0:HasComponent Object 4:MachineryBuildingBlocks
-
OPC-40530 – OPC UA for Laser SystemsHasComponent Object SetUp 0:StateType 0:HasComponent Object LaserReady 0:StateType 0:HasComponent Object Maintenance 0:StateType 0:HasComponent Object Error 0:StateType 0:HasComponent Object LaserOn 0:StateType ... indicates that the laser system is merely missing a trigger before actively emitting radiation. Maintenance indicates all states where the system is currently not able to operate
-
OPC-40550-1 – OPC UA for Woodworking Machines - Part 1: Vertical Interfaceemergency from the line controller controller . The MaintenanceRequired Variable is True if maintenance is required. The FeedRuns Variable is True if the feed is running on a throughfeed machine