Search
23 result(s) for DataVariable
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model3.1.7 DataVariableDataVariable Variables that represent values of Objects , either directly or indirectly for complex Variables , where the Variables are always the TargetNode of a HasComponent Reference
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.5.3 DataVariablescontains a stream of bytes. The stream of bytes may be defined as a DataVariable that is an array of bytes. Properties may be used to expose the creation time ... owner of the file Object . For example, if a DataVariable is defined by a data structure that contains two fields, "startTime" and "endTime" then it might
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.6.1 GeneralReference . In this example, a setpoint parameter "SP" is represented as a DataVariable in the AddressSpace . This DataVariable is part of an Object not shown in the figure ... that can be used by other Objects , a specialised VariableType is used. Each setpoint DataVariable that uses this common definition will have a HasTypeDefinition Reference that identifies the common
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.2 Variable NodeClassModellingRules ). HasProperty 0..* HasProperty References are used to identify the Properties of a DataVariable . Properties are not allowed to be the SourceNode of HasProperty References. HasComponent 0..* HasComponent References ... NodeVersion O String The NodeVersion Property is used to indicate the version of a DataVariable . It does not apply to Properties . The NodeVersion Property is updated each time a Reference
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.6.4 DataVariableDataVariable DataVariables represent the content of an Object . DataVariables are defined using the Variable NodeClass , specified in Table 13 . DataVariables identify their Properties using HasProperty References . Complex DataVariables use HasComponent ... References to expose their component DataVariables . The Property NodeVersion indicates the version of the DataVariable . The Property LocalTime indicates the difference between the SourceTimestamp of the value and the standard
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClassoutput argument. Input1 as a numeric input argument with a HasArgumentDescription Reference to a DataVariable Variable which provides the default value 42. Input2 as a numeric input argument with
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelTargetNode is a Variable , the SourceNode shall be an Object , an ObjectType , a DataVariable or a VariableType . By using the HasComponent Reference , the Variable is defined as DataVariable
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model7.22.1 OverviewVariable which represents a field of the Structure DataType. The BrowseName of a DataVariable which is exposed shall be the same as the field name of the Structure DataType
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.51 StructureFieldVariable that contains the Structure Value . In this case the BrowseName of the DataVariable shall be the same as the StructureField name and the NamespaceIndex of the BrowseName shall
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Modeldifferent syntax can help. The following points identify when it shall be a DataVariable . If it is a complex Variable or it should contain additional information in the form
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.3.2 ServerCapabilitiesTypesetting by adding the MaxStringLength Property defined in OPC 10000-3 to an individual DataVariable . If a Server does not impose a maximum number of bytes or is not able ... setting by adding the MaxByteStringLength Property defined in OPC 10000-3 to an individual DataVariable. If a Server does not impose a maximum number of bytes or is not able
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model7.1 Generalstandard Property NodeVersion , defined in OPC 10000-3 , into the BaseDataVariableType , stating that each DataVariable of the Server will provide a NodeVersion
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelBaseVariableType . It is used as the type definition whenever there is a DataVariable having no more concrete type definition available. This VariableType is the base VariableType for VariableTypes of DataVariables
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model7.29 BitFieldTypeEach bit field defined by the BitFieldDefinitions shall also be exposed as a child DataVariable . The BrowseName of the DataVariable shall be the same as the BitFieldDefinition name field ... fields may be defined by using the Optional Modeling Rule for the child DataVariable which represents the bit field. An application accessing a BitFieldType with an optional bit field should
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model12.45 BitFieldDefinitionDataType of the field is defined by the DataType of the BitFieldType's child DataVariable for the field. When the DataType of the field is an Integer the most significate
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Modelexample, the ServerStatus Variable of the Server Object is modelled as a complex DataVariable having the ServerStatusDataType providing all information about the Server status. But it also exposes the CurrentTime ... simple DataVariable , because a client may want to read only the current time of the Server , and is not interested in the build information
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelPublishRequestCount . Therefore, each entry of the array is also exposed individually as a complex DataVariable , having each entry exposed as simple data. Note that it is never necessary to expose
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Modelsubtyped, because they should reflect the data structure of the DataType of the complex DataVariable
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessFigure 4 - Representation of DataItems in the AddressSpace Each DataItem is represented by a DataVariable with a specific set of Attribute s. The TypeDefinition reference indicates the type
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access5.1.2 Annotations PropertyAnnotations Property The DataVariable or Object that has Annotation data will add the Annotations Property as shown in Table 2 . Table 2 - Annotations Property Name Use Data Type Description Annotations
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregateshighest level may support Aggregate functionality for Interpolative, Total, Average, and others, DataVariable X only supports Interpolative, Total and Average, while DataVariable Y supports Average, a vendor defined Aggregate
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.1.9 Parameterentry: In the information model it is synonymous to an OPC UA DataVariable
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation6.3.1 HasStatisticComponentsubtypes. The TargetNode of this ReferenceType shall be an Object or DataVariable . If an Object is referenced, the Object shall not implement the IStatisticsType Interface , in order to avoid ambiguity