Search
75 result(s) for Connections
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.3 PubSubConfigurationRefDataTypereferencing, it shall be set to 0. ConnectionIndex UInt16 Specifies the index within the Connections array of the PubSubConfiguration if the connection, group, reader or writer bits
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts1 Scopeconfiguration/parameterisation data (non-safety and safety) using OPC UA PubSub in combination with UAFX Connections and basic diagnostics. A future version of the UAFX specifications is expected to address other
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts3.1.5 ConnectionManagerConnectionManager entity that interacts with AutomationComponents to establish Connections between FunctionalEntities Note 1 to entry: See OPC 10000-81 for a description of the ConnectionManagerType
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts5.4.1 GeneralGeneral UAFX defines a mechanism for standardising the exchange of information used for establishing Connections between AutomationComponents (see 6.2 ) in an OfflineEngineering environment (see 6.4 ). From initial AutomationComponent development
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts5.4.3 Application engineeringengineering tool and adds the information needed for Controller A and B Connections . Engineer B may import additional Descriptors describing components used with their Controller or other Controllers
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts5.4.6 System integrationConnectionManager uses OPC UA Methods exposed by each AutomationComponent to establish the configured Connections when the system goes operational, as shown in Figure 8 . See clause 6.2 for more details ... Connections and the ConnectionManager . See OPC 10000-81 for more details. Figure 8 - Connection establishment
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Conceptsvendors to describe the Controller's assets, automation functions, and a standard interface for Connections that provides interoperability for exchanging data. AutomationComponents, Assets, and FunctionalEntities also include identification information, allowing ... compatibility to be verified for each Connection . This release of the UAFX specification defines Connections using OPC UA PubSub for data exchange, including the usage of TSN. Connections using
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Conceptsdata information. Future releases are planned to include the exchange of event information. Connections are mapped to a communication model such as PubSub or Client Server and different QoS classes ... application configuration. OPC 10000-81 formally describes Connections . The ConnectionManager , described in OPC 10000-81 , is the entity responsible for establishing Connections . The ConnectionManager may be part of an AutomationComponent
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model4.4.1 Overviewhave relationships to other FunctionalEntities . The Object Model also includes a representation of Connections (communication) between FunctionalEntities . Figure 5 - FunctionalEntity illustration FunctionalEntities are designed to describe the functionality
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model4.4.2 FunctionalEntityTypedescribes information related to the status of its functionality, including the status of any Connections . This could include the generation of Events or Alarms related to problems or issues encountered
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelmonitoring purposes. Information related to these interactions is represented in the FunctionalEntity by Connections (see Figure 8 ). Figure 8 - Example Connection between FunctionalEntities The process of establishing a Connection
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model4.7.1 OverviewOverview A ConnectionManager is an optional entity that interacts with multiple AutomationComponents to establish Connections between FunctionalEntities . The ConnectionManager can execute on any Server supporting the OPC UA FX Information ... represented by the ConnectionManagerType , which defines functionality and interfaces to manage the establishment of Connections between FunctionalEntities . Several ConnectionManagers within a network could establish Connections independently of each other
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelCreating / Monitoring / Closing Connections Connections to be created are part of a ConnectionManager configuration ( ConnectionConfigurationSet ). An AutomationComponent and the included FunctionalEntities report the status of Connections that are part ... knows when to create a Connection . respond to external or internal commands. monitor the Connections they create. Possible reasons for monitoring Connection status include: An application or ConnectionManager monitors ConnectionEndpoints
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.1 OverviewThese concepts include Connection establishment and bidirectional communication. The establishment of Connections further requires concepts such as identity and compatibility verification of Asset and FunctionalEntity , establishing control via ControlGroup selection
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.5.6.1 OverviewOverview Connections between FunctionalEntities are designed to exchange data by utilising OPC UA communication models. This revision of the specification supports the PubSub communication model as defined
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.5.6.2.1 OverviewOverview This clause illustrates how Connections utilise the PubSub communication model, focusing on three use cases relevant in the context of industrial automation and the design of AutomationComponents . These
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelMultiple Connections using unicast network messages This use case, illustrated in Figure 13 , typically applies to AutomationComponents that host multiple FunctionalEntities and/or nested FunctionalEntities . Figure 13 - Multiple Connections using unicast ... network messages (aggregated) Figure 13 illustrates two Connections , each between two PubSubConnectionEndpoints . Each PubSubConnectionEndpoint on AC_A (and similarly on AC_B) references a DataSetWriter (and DataSetReader) that is located
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.5.6.2.5 DataSetMetaDataDataSetMetaData Connections are configured by an engineering tool on behalf of Descriptors and are deployed to a ConnectionManager (see 5.5.2 ). Independent of the lifetime of a Connection, another engineering tool
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelactual configuration is available. They can be exchanged between vendors, allowing vendors to configure Connections without having all the required data defined. The resolution of this configuration information into
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model5.9 Well Known RolesBrowseName Suggested Permissions 3:ConnectionAdmin The Role is allowed to establish, close, and modify Connections between FunctionalEntities . This includes reading and writing connection configuration settings, reading endpoint and connection capabilities ... executing methods related to the management of Connections . It is intended to be a non-human Role . For a detailed description of Roles
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.1 OverviewFunctionalEntities in a given model. It exposes a Method that is used to establish Connections between FunctionalEntities . An overview of the AutomationComponentType is illustrated in Figure 18 . Figure 18 - AutomationComponentType
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelAutomationComponentCapabilitiesType Folder that describes the functionality provided by an AutomationComponent (e.g., number of supported Connections , etc.). The optional ConformanceName provides the URL to the product's listing
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.1 OverviewOverview The EstablishConnections Method establishes one or more Connections . The ConnectionManager typically calls it. It allows for creating ConnectionEndpoints , establishing control, verifying FunctionalEntity and Asset compatibility, applying ConfigurationData , and configuring ... used for data exchange. It is recommended that this Method be restricted to Client connections that have the well-known Role ConnectionAdmin as defined in Clause
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.2 EstablishConnections signatureAssetVerifications shall be null or empty. ConnectionEndpointConfigurations Provides configuration information for Connections . For a formal definition of the ConnectionEndpointConfigurationDataType, see 10.14 . If CommandMask VerifyFunctionalEntityCmd , CreateConnectionEndpointCmd , EstablishControlCmd , SetConfigurationDataCmd , ReassignControlCmd , SetCommunicationConfigurationCmd ... empty. CommunicationConfigurations Provides the ConfigurationData specific to the communication model utilised by the provided Connections . For a formal definition of the CommunicationConfigurationDataType , see 10.10 . If CommandMask SetCommunicationConfigurationCmd is set, CommunicationConfigurations
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.5.1 CloseConnections signatureCloseConnections signature This Method disables one or more Connections . Optionally, it also removes these Connections . It is recommended that this Method has the execute privilege for the well-known Role ... StatusCode[] Results ); Table 22 - CloseConnections Method arguments Argument Description ConnectionEndpoints The list of Connections to be closed. Remove When TRUE, the Objects dynamically created for the Connection are removed. Results
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelrules associated with an OptionalPlaceholder. The optional SupportsPersistence indicates whether this AutomationComponent supports persistent Connections. For additional details on persistence, see 6.6 . If this capability is not present ... FALSE, the AutomationComponent does not support persistent Connections. The optional MaxFunctionalEntities indicates the maximum number of FunctionalEntities that the AutomationComponent can support . The optional MaxConnections indicates the maximum number
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpart of the AutomationComponent . When the preconfigured PublishedDataSet is used in a ConnectionConfigurationSet , Connections shall be established to one or more of the FunctionalEntities whose variables are present
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpart of the AutomationComponent . When the preconfigured StandaloneSubscribedDataSet is used in a ConnectionConfigurationSet , Connections shall be established to one or more of the FunctionalEntities whose variables are present
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpresent and set to TRUE, the FunctionalEntity requires a feedback signal for all Connections . A feedback signal is represented by the reception of either data or a heartbeat. The following
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelEstablished control on related ControlGroups Communication model Objects An AutomationComponent indicates support for persistent Connections ; see SupportsPersistence in 6.2.6 . Non-persistent ConnectionEndpoints following a power cycle behave
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelempty String . Annex E provides examples of PubSubConnectionEndpoints for the various types of Connections
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.1 OverviewConnectionManager uses the configuration data stored in a ConnectionConfigurationSet (see 6.8 ) to establish Connections . Optional Methods are provided by ConnectionManagerType to allow Clients to manage editing and trigger the processing ... Connections . A ConnectionManager is represented by an instance of ConnectionManagerType ; see 12 for details on its location in the UAFX Information Model . Figure 34 - ConnectionManagerType illustration ConnectionConfigurationSets may be serialised
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelonly instances of ConnectionConfigurationSetType, which provide the data required by a ConnectionManager to establish Connections . This Folder may also contain other Folders that can be used to organise the ConnectionConfigurationSets ... more ConnectionConfigurationSets in a single Call . ProcessConnectionConfigurationSets causes the ConnectionManager to manage Connections contained in one or more ConnectionConfigurationSets in a single Call (see 6.7.5 ). In addition, vendor-specific means
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.2 Establishing ConnectionsEstablishing Connections To establish Connections defined in a ConnectionConfigurationSet , the ConnectionManager shall use the sequence of Calls illustrated in Figure 36 to the EstablishConnections Method on the involved AutomationComponents ... establish ConnectionEndpoints on an AutomationComponent . The Method allows for the establishment of multiple Connections with a single Call . The number of Connections to be established with a single Call
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.3.3 Closing ConnectionsClosing Connections To close Connections defined in a ConnectionConfigurationSet , a ConnectionManager shall use the CloseConnections Method on the AutomationComponents (see 6.2.5 ). A ConnectionManager may remove or disable the Connections ... CloseConnections returns any error, the ConnectionManager shall complete closing all Connections in the ConnectionConfigurationSet and initiate a ProcessingToError transition in the ConnectionConfigurationSetStateMachine (see 6.9 ). If any of the ConnectionEndpoints require
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.1 Overviewrequested ConnectionConfigurationSets according to the specified Action : ActionEstablishConnectionsEnabled , ActionEstablishConnectionsDisabled , and ActionEstablishConnections - establish all Connections contained in the ConnectionConfigurationSets (see 6.7.5.3 ) ActionRemoveConnections - disable and remove all Connections contained in the ConnectionConfigurationSets ... ActionEnableConnections - enable the communication model for all Connections contained in the ConnectionConfigurationSets (see 6.7.5.3.3 ) ActionDisableConnections - disable the communication model for all Connections contained in the ConnectionConfigurationSets
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.1 ActionEstablishConnectionsEnabled / ActionEstablishConnectionsDisabled / ActionEstablishConnectionsActionEstablishConnections Calling ProcessConnectionConfigurationSets with Action set to ActionEstablishConnectionsEnabled , ActionEstablishConnectionsDisabled , or ActionEstablishConnections shall establish the Connections contained in the ConnectionConfigurationSets and their related communication model. Establishing connections shall follow the behaviour ... requested Action as follows: Calling ProcessConnectionConfigurationSets with Action set to ActionEstablishConnectionsEnabled shall establish all Connections contained in the ConnectionConfigurationSets with a disabled communication model and include EnableCommunicationCmd in the command
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.2 ActionRemoveConnectionsActionRemoveConnections Calling ProcessConnectionConfigurationSets with Action set to ActionRemoveConnections shall remove all Connections contained in the ConnectionConfigurationSets and their related communication model. For each ConnectionConfigurationSet , the ConnectionManager shall call the CloseConnections
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.3 ActionEnableConnectionsActionEnableConnections Calling ProcessConnectionConfigurationSets with Action set to ActionEnableConnections shall enable all Connections contained in the ConnectionConfigurationSets . For each ConnectionConfigurationSet , the ConnectionManager shall call the EstablishConnections Method, containing the EnableCommunicationCmd
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.4 ActionDisableConnectionsActionDisableConnections Calling ProcessConnectionConfigurationSets with Action set to ActionDisableConnections shall disable all Connections contained in the ConnectionConfigurationSets . For each ConnectionConfigurationSet , the ConnectionManager shall call the CloseConnections Method (see 6.2.5 ) with Remove
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelcapability of the ConnectionManager Information Model to report the status of all the Connections created by this ConnectionManager that have a ConnectionEndpoint on this Server. If this capability ... provided, or false, the ConnectionManager Information Model does not report the current status of Connections. NOTE In some cases, this status might include the status of the remote Connection . MonitorsAllConnectionEndpoints
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.8.1 OverviewOverview The ConnectionConfigurationSetType is an ObjectType representing one or more Connection configurations. Connections are grouped in a set, for example, to allow sharing communication model configurations by multiple Connections ... expose the ConnectionConfigurationSets in its AddressSpace . A ConnectionConfigurationSet exposes diagnostic information about the Connections as part of its Information Model . It also allows Connection configurations to be available for modification
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeloccurs during the Connection establishment sequence, establishing the set shall stop, and all established Connections that are part of this set shall be closed (see 6.7.3.2 ). It is recommended that ... ConnectionConfigurationSet by having a different NodeId . ConnectionsDiagnostics provides an array of diagnostic information for Connections included in this ConnectionConfigurationSet . There shall be one element in this array for each
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.9.1 Overviewmachine is defined as a mechanism to coordinate actions executed internally (a ConnectionManager establishing Connections ) that involve the processing of a ConnectionConfigurationSet . The States and Transitions that comprise the state
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelthis State indicates that it is currently being processed by the ConnectionManager (i.e., Connections are being established). Internals of the processing executed in this State are described in 6.7.5.3 . Error ... vendor-specific means. While in State Processing , the ConnectionManager establishes or closes the Connections contained in the ConnectionConfigurationSet ; for details, see 6.7.5.3 . ProcessingToReady - This transition shall be initiated
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnectionManager Base PubSubCommunicationFlowConfigurationType indicates the usage of PubSub as the communication model for the Connections . It is formally defined in 6.13.3 . ClientServerCommunicationFlowConfigurationType may be defined in a future release ... indicate the usage of Client Server as the communication model for the Connections
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelUAFX ConnectionManager Base AutomationComponentNode specifies the AutomationComponent that is to be used for establishing Connections . If a PortableRelativePath is specified, the path shall be relative to FxRoot . CommandBundleRequired , when TRUE ... CommunicationModelConfig provides the ConfigurationData specific to the communication model utilised by the Connections
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.16.1 OverviewCommunicationModelConfigurationType ObjectType provides the configuration data specific to the communication model utilised by the Connections . The CommunicationModelConfigurationType is illustrated in Figure 47 . Figure 47 - CommunicationModelConfigurationType illustration PubSubCommunicationModelConfigurationType provides the configuration ... data specific to the usage of PubSub as the communication model for the Connections . It is formally defined in 6.16.3 . ClientServerCommunicationModelConfigurationType indicates the usage of Client Server as the communication
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelPubSubCommunicationModelConfiguration The PubSubConfiguration modifies the existing PubSub configuration on the addressed Server when establishing Connections . The PubSubConfiguration2DataType is defined in OPC 10000-14 . Namespaces contains namespace URIs for NamespaceIndex used ... identifiers in the PubSubConfiguration . OPC UA FX allows multiple ConnectionManagers to establish Connections to a single AutomationComponent independently of each other. It also allows any Client to establish Connections
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model9.2.1 Overviewdescribes the attributes to be applied to open secure communication to the Server . Multiple Connections may refer to the same instance of ServerAddressType . The ServerAddressType is illustrated in Figure
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelremaining bits to indicate the kind of processing that has just finished. For all Connections for which all required operations were successfully finished, a ConnectionManager shall clear the Error ... NoError and shall set EndpointStatus (1 and/or 2) to Good . For all Connections for which not all operations required in the last processing were successfully finished, a ConnectionManager shall
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelD.3.1 Overviewfunctionality that a FunctionalEntity might expose. This includes Inputs , Outputs , ControlGroups and the resulting Connections . It will also describe the use of pre-configured DataSets and dynamically created DataSets
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelD.3.7.4 Using ControlGroups with Connections ControlGroups can be used with Connections . This example is an extension of the simple ControlGroup . Assume that the EngineeringUnit of Temperature (see Figure D.28 ) should
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.2.1 OverviewE.2.1 Overview The ConnectionManager uses the information in the ConnectionConfigurationSet to establish all contained Connections . The configuration information required as input to call EstablishConnections on a particular AutomationComponent ... NOTE The interaction of the ConnectionManager with AutomationComponents to establish Client Server -based Connections will be provided in a future version of this document. If a PubSubCommunicationModelConfiguration was generated
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.1 OverviewConnectionConfigurationSet. Note, however, that as shown in E.1.3 , a ConnectionConfigurationSet can contain multiple Connections , which could have different connection types. The examples provide illustrations of how PubSub communication
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.7 PubSub DataSetsF.1.5 ) or within the vendor-specific download format. A ConnectionConfigurationSet might contain multiple Connections that all need to communicate as a set. In this case, the ConnectionManager and/or the engineering ... tool can also optimise communication by grouping Variables for multiple Connections into a single DataSet or into a single network message. For example, if the ConnectionConfigurationSet has three Connections between
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpush model configuration, it is recommended that the ConnectionManager establish the Connections on the AutomationComponents before updating the SKS . It is recommended to perform as much configuration as possible ... available. For a pull model configuration, it is recommended that the ConnectionManager establish the Connections on the AutomationComponents after updating the SKS . If the SKS rejects GetSecurityKeys (e.g., SecurityGroups have
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelgrouping is needed, the parameter is a null or empty String array. False Connections 4:ConnectionConfigurationConfDataType[] A list of Connection configurations to be established. False CommunicationFlows 4:CommunicationFlowConfigurationConfDataType[] A list ... communication model-specific configurations to apply to Connections. True ServerAddresses 4:ServerAddressConfDataType[] A list of addressing information for AutomationComponents . False AutomationComponentConfigurations 4:AutomationComponentConfigurationConfDataType[] A list of AutomationComponents used for Connection
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelAutomationComponentNode 4:NodeIdentifier AutomationComponentNode specifies the AutomationComponent that is to be used for establishing Connections . If a RelativePath is specified, the path shall be relative to FxRoot . False AutomationComponentNodeSelection ... CommunicationModelConfig 4:CommunicationModelConfigurationDataType Provides the ConfigurationData specific to the communication model utilised by the Connections . If the optional CommunicationModelConfig is to be omitted, the field shall be set to null
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.3.2.3 ElementRemoveMethod on all affected AutomationComponents (see 6.2.5 ) with Remove set to TRUE for all Connections contained in the ConnectionConfigurationSet
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.3.2.4 ElementReplaceaffected AutomationComponents (see 6.2.5 ) with Remove set to TRUE for all contained Connections in the ConnectionConfigurationSet . The operation ElementReplace does not include processing the new ConnectionConfigurationSet . Processing can be triggered
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnection (the side that is in the local AutomationComponent ) or it could not monitor Connections at all (see Figure G.1 ). The ConnectionManager has capabilities (see 6.7.6 ) indicating the behaviour
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.1 Overviewnetwork containing UAFX Stations (see 6.4.3 ) and other IA-stations (see 6.4 ) such that Connections can be handled with appropriate QoS. With this release , UAFX Stations can use Best Effort
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.4.1 Generalthis clause follows the general workflow from OPC 10000-80 for the configuration of Connections between FunctionalEntity inputs and outputs. The workflow described in this clause goes into the details ... related to configuring the QoS required by those Connections . This workflow is divided into four phases: Application and QoS engineering, network configuration, system integration, and connection establishment and operation
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.4.2 Application and QoS engineeringfinal step, Connection configurations are transferred to a ConnectionManager that establishes the Connections during the workflow's connection establishment and operation phase (see 5.6.4.5 ). This subclause describes the details ... Input and output Variables in the FunctionalEntity expose the data to be exchanged using Connections with FunctionalEntities in another Controller . The Variables PublisherCapabilities and SubscriberCapabilities, also contained in the AutomationComponent
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.4.4 System integrationsystem integration phase, a System Commissioner makes the necessary adjustments to adapt the Connections and network configurations for the existing network using a generic OPC UA Client or vendor-specific
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networkingoperation The connection establishment and operation phase begins with the ConnectionManager establishing the Connections described in its Information Model . Connection establishment is either initiated by the ConnectionManager's internal logic ... Figure 11 - PubSub QoS and addressing configuration variables The ConnectionManager establishes Connections using the Connection configuration as set up by the Controls Engineer (see 5.6.4.2 ) and System Commissioner
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringsubscriber capabilities, whereas non-relevant information would not be included. For configuration of the Connections , a special set of configuration information is needed that describes the ConnectionConfigurationSets . This
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineering8.3.2 Descriptor Importneeds to know what data Controller A is providing or is required for the Connections . After receiving the Descriptor , Engineer B imports it into an engineering tool and uses
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.3 UAFX AutomationComponentMaxConnections Variable in the ComponentCapabilities Folder a nd supports the claimed number of Connections . Note the actual maximum number of connections supported may be reduced during runtime due to resource ... Variable in the ComponentCapabilities Folder a nd supports at least the claimed number of Connections . Server UAFX AutomationComponent MaxFunctionalEntities Includes the MaxFunctionalEntities Variable in the ComponentCapabilities Folder and supports
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerFile content. Server UAFX ConnectionManager Exposes CCSs Exposes a ConnectionConfigurationSet for each of its Connections . Client UAFX Client ConnectionManager VerifyAsset Is capable of issuing the VerifyAssetCmd command of the EstablishConnections
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.5 UAFX SKS Push 2023 FacetPush Facet . This Facet includes the Security Key Server functionality needed for securing UAFX Connections using the push model . This Facet supersedes the UAFX SKS Push Facet . Table 44 - UAFX
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesConnectionManager 2024 Facet. This Facet includes the functionality a UAFX ConnectionManager needs to establish Connections between FunctionalEntities . This Facet supersedes the UAFX ConnectionManager Facet . Table 45 - UAFX ConnectionManager 2024 Facet
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesConnection Monitoring Facet. This Facet includes the functionality needed for a ConnectionManager to monitor Connections . Table 46 - UAFX ConnectionManager Connection Monitoring Facet Group Conformance Unit / Profile Title Optional UAFX ConnectionManager
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesFeature Do we need a Conformance Unit requiring a minimum number of UAFX Connections Added UAFX AutomationComponent MinConnections CU and the new CU to the new UAFX AutomationComponent 2024 Facet ... Added CU UAFX ConnectionManager Exposes CCSs - Exposes a ConnectionConfigurationSet for each of its Connections . 9787 Errata The Base Bridge Component Facet description contains misleading text. Removed the phrase "describes