Search
21 result(s) for ConditionId
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.1 GeneralAlarm or Condition . Instances not exposed in the AddressSpace still have a ConditionId ( NodeId ). This NodeId can be the target of references in the AddressSpace even though the target node
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypedefined in 10000-5 . The NodeId of the Condition instance is used as ConditionId . It is not explicitly modelled as a component of the ConditionType . However, it can be requested ... detailed definition of the SelectClause in an Event Subscription . Table 10 - ConditionId SimpleAttributeOperand Illustration Name Type Description SimpleAttributeOperand typeId NodeId NodeId of the ConditionType Node browsePath[] QualifiedName empty attributeId IntegerId
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsObjects which have a state which changes over time. Each Condition instance has a ConditionId as an identifier which uniquely identifies it within the Server . This Condition (and it representative ... ConditionId) follows the same rules associated with Nodes (and their representative NodeIds ) in the AddressSpace (see 10000-3 ). Therefore, once a Condition is created in a system that does
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.4 Disable MethodAddressSpace. Therefore, all Servers shall allow Clients to call the Disable Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the ConditionType Node
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.5 Enable MethodAddressSpace. Therefore, all Servers shall allow Clients to call the Enable Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the ConditionType Node ... exposed, then it may be difficult for a Client to determine the ConditionId for a disabled Condition. Since Condition instances are not required to be defined in the AddressSpace
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.6 AddComment MethodTherefore, all Servers shall also allow Clients to call the AddComment Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the ConditionType Node
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.7.3 Acknowledge MethodAddressSpace. Therefore, Servers shall allow Clients to call the Acknowledge Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AcknowledgeableConditionType Node . Signature ... AcknowledgeableConditionType or MethodId does not refer to a Method for the specified Object or ConditionId . Bad_EventIdUnknown See Table 137 for the description of this result code. Bad_NodeIdInvalid Used
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.7.4 Confirm MethodAddressSpace. Therefore, Servers shall allow Clients to call the Confirm Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AcknowledgeableConditionType Node. Signature ... method id does not refer to a method for the specified object or ConditionId . See 10000-4 for the general description of this result code. Bad_EventIdUnknown See Table
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.5 Reset MethodAddressSpace. Therefore, Servers shall allow Clients to call the Reset Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.7 Silence MethodAddressSpace. Therefore, Servers shall allow Clients to call the Silence Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.8 Suppress MethodAddressSpace. Therefore, Servers shall allow Clients to call the Suppress Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.10 Unsuppress MethodAddressSpace. Therefore, Servers shall allow Clients to call the Unsuppress Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.12 RemoveFromService MethodAddressSpace. Therefore, Servers shall allow Clients to call the RemoveFromService Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.14 PlaceInService MethodAddressSpace. Therefore, Servers shall allow Clients to call the PlaceInService Method by specifying ConditionId as the ObjectId. The Method cannot be called with an ObjectId of the AlarmConditionType Node . Signature
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.2 Unshelve MethodTherefore, all Servers shall also allow Clients to call the Unshelve Method by specifying ConditionId as the ObjectId where the ConditionId is the Condition that has Shelving child . The Method
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.4 TimedShelve MethodTherefore, all Servers shall also allow Clients to call the TimedShelve Method by specifying ConditionId as the ObjectId where the ConditionId is the Condition that has the Shelving child ... with an ObjectId of the ShelvedStateMachineType Node . This Method can be called on any ConditionId , even if it is not active. The timer will start on Method invocation. The Alarm
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.6 OneShotShelve MethodTherefore, all Servers shall also allow Clients to call the OneShotShelve Method by specifying ConditionId as the ObjectId where the ConditionId is the Condition that has the Shelving child ... with an ObjectId of the ShelvedStateMachineType Node . This Method can be called on any ConditionId , even if it is not active. Signature OneShotShelve( ); Method Result Codes are defined in Table
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.10.2 AuditConditionEventTypewill be used as defined. The inherited Property SourceNode shall be filled with the ConditionId . The SourceName shall be "Method/" and the name of the Service that generated
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsEvents are coming from the same Condition instance and therefore have the same ConditionId . Figure B.1 - Single state example Table B.1 - Example of a Condition that only keeps the latest
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsEvents are coming from the same Condition instance and have therefore the same ConditionId . Figure B.2 - Previous state example Table B.2 - Example of a Condition that maintains previous states
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsEvents are coming from the same Condition instance and therefore have the same ConditionId . The Client subscription includes an event filter that excludes suppressed or out of service conditions