10.1 Conformance Units

This chapter defines the corresponding Conformance Units for the OPC UA Information Model for Machinery – Energy Management.

Table 13 – Conformance Units for Machinery – Energy Management
Category Title Description
ServerMachinery Energy Base StructureSupports at least one MachineryItem supporting the Consumption Object having at least one sub-folder following the predefined BrowseNames of this specification.
ServerMachinery Energy Main groupingEach MachineryItem supporting the Consumption Object with a sub-folder according to this specification provides a Main Object of EnergyMeasurementType for each of those sub-folders.
ServerMachinery Energy Non Electrical BaseSupports INonElectricalEnergyType and at least one instance of EnergyMeasurementType implementing the interface.
ServerMachinery Energy Non Electrical Mass FlowSupports IBaseFlowType, IMassFlowType and at least one instance of EnergyMeasurementType implementing IMassFlowType.
ServerMachinery Energy Non Electrical Volume FlowSupports IBaseFlowType, IVolumeFlowType and at least one instance of EnergyMeasurementType implementing IVolumeFlowType.
ServerMachinery Energy ContainsSupports the Contains ReferenceType and at least one instance using the ReferenceType.