17 result(s) for UInt16
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model12.2.9.12 UInt16UInt16 The representation in the AddressSpace of the UInt16 DataType is defined in Table 184 . Table 184 - UInt16 definition Attributes Value BrowseName UInt16 IsAbstract FALSE References NodeClass BrowseName DataType TypeDefinition
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelAccessRestrictionType This is a subtype of the UInt16 DataType with the OptionSetValues Property defined. It is used to define the access restrictions of a Node . The AccessRestrictionType is formally defined
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.3 FilterOperatorordered value are restricted to the DataTypes Byte , Int16 , Int32 , Int64 , SByte , UInt16 , UInt32 , UInt64 , Float , Double and DateTime . When testing for equality, a Server shall treat null and empty ... DateTime Double ExpandedNodeId Float Guid Int16 Int32 Int64 NodeId SByte StatusCode String LocalizedText QualifiedName UInt16 UInt32 UInt64 XmlElement Boolean
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.40.2.3 EncryptedSecret Formattotal length of the Padding, not including the PaddingSize , is encoded as a UInt16 . The individual bytes of the Padding are set to the least significant byte of the PaddingSize ... ByteString The signing and/or encrypting Certificate . SigningTime DateTime When the Signature was created. KeyDataLength UInt16 The length, in bytes, of the KeyData that follows If the KeyData is encrypted this
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.4.2 NetworkMessage layoutdefault value if ExtendedFlags1 is omitted 001 The PublisherId is of DataType UInt16 010 The PublisherId is of DataType UInt32 011 The PublisherId is of DataType UInt64 100 The PublisherId ... receiver shall skip messages where the reserved bits are not false. WriterGroupId UInt16 Unique id for the WriterGroup in the Publisher. A Subscriber can skip NetworkMessages from WriterGroups it does
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubGroupFlags WriterGroupId GroupVersion NetworkMessageNumber SequenceNumber Additional restrictions: The datatype for the PublisherId shall be UInt16 or UInt64 The NetworkMessage header layout is shown in Figure A.1 . Figure A.1 - UADP NetworkMessage ... Type with one of the two following options 001 The PublisherId is of DataType UInt16 011 The PublisherId is of DataType UInt64 Bit 3: DataSetClassId enabled = 0 Bit 4: SecurityHeader
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety7.2.3.6 Calculation of a CRC signatureRQ7.23] If SafetyData is longer than one octet (e.g. if it is of DataType UInt16 , Int16 or Float ), it shall be decoded and encoded using little endian order in which ... endian machine, using an example SafetyData with the following fields: Int32 var1 UInt32 var2 UInt16 var3 Int16 var4 Boolean var5 For the example given above, the STrailer (without
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelVariable Speed UInt64 AnalogUnitType Mandatory HasComponent Variable Duplex Duplex BaseDataVariableType Mandatory HasComponent Variable MaxFrameLength UInt16 BaseDataVariableType Mandatory Conformance Units BNM Ethernet Base Info Speed of DataType UInt64 specifies the configured ... clause 30.3.1.1.32, aDuplexStatus). The Duplex DataType is defined in 5.3.1.1 . MaxFrameLength of DataType UInt16 indicates the MAC frame length (including FCS bytes) at which frames are dropped for being
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network Model5.2.6 ISrClassType InterfaceVariable Id Byte BaseDataVariableType Mandatory HasComponent Variable Priority Byte BaseDataVariableType Mandatory HasComponent Variable Vid UInt16 BaseDataVariableType Mandatory Conformance Units BNM TSN Base Info Id is a Byte and specifies ... SRclassPriority). Only Values between 0 and 7 shall be used. Vid is an UInt16 and contains the SR_PVID (item i) in IEEE 802.1Q-2018 clause 35.2.1.4) that
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network ModelTypeDefinition ModellingRule Subtype of the BaseInterfaceType defined in OPC 10000-5 HasComponent Variable VlanId UInt16 BaseDataVariableType Mandatory HasComponent Variable PriorityCodePoint Byte BaseDataVariableType Mandatory Conformance Units BNM TSN Config VlanId ... DataType UInt16 defines the 12-Bit VLAN-Identifier of the VLAN tag in the Ethernet header for the related stream. Only values between 0 and 4095 shall be used according
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.2 UAFX BaseFxRoot Server UAFX Controller Datatype Support Is capable of supporting Boolean , SByte , Byte , Int16 , UInt16 , Int32 , UInt32 , and Float datatypes. Server UAFX Preconfigured PublishedDataSet If preconfigured PublishedDataSets exist, the Server
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.3.3.11 Variable Vendor_IdentifierVariable Vendor_Identifier This OPC UA Property , of DataType UInt16 , represents the BACnet property Vendor_Identifier. This property represents a unique identification code, assigned by ASHRAE. The code is used
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.3.2.3 Variable Backup_Failure_TimeoutVariable Backup_Failure_Timeout This OPC UA Property , of DataType UInt16 , represents the BACnet property Backup_Failure_Timeout. The Backup_Failure_Timeout value represents the time, in seconds, that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.3.2.4 Variable Backup_Preparation_TimeVariable Backup_Preparation_Time This OPC UA Property , of DataType UInt16 , represents the BACnet property Backup_Preparation_Time. The Backup_Preperation_Time value represents the time, in seconds, that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelVariable Restore_Preparation_Time This OPC UA Property , of DataType UInt16 , represents the BACnet property Restore_Preparation_Time. The Restore_Preperation_Time value represents the time, in seconds, that
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.3.2.6 Variable Restore_Completion_TimeVariable Restore_Completion_Time This OPC UA Property , of DataType UInt16 , represents the BACnet property Restore_Completion_Time. The Restore_Completion_Time variable value represents the time, in seconds, that
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsHasProperty Variable Name 0:String 0:PropertyType M 0:HasProperty Variable Components 0:UInt16[] 0:PropertyType M Name : Name of the production dataset that should be transferred from the client ... Storage is CONTROL_SYSTEM_1 or FILE_AND_CONTROL_SYSTEM_2. Array of UInt16 . See possible values in Table 115 . If Components has the array length 0 then complete production