Search
31 result(s) for Parameters
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicesessential aspect introduced by the TopologyElementType . FunctionalGroups are used to structure Nodes like Properties , Parameters and Methods according to their application such as configuration, diagnostics, asset management, condition monitoring ... MethodSet are defined as standard containers for systems that have a flat list of Parameters or Methods with unique names. In such cases, the Parameters are components
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.4.1 ModelThis subtype of the OPC UA FolderType is used to structure Nodes like Properties , Parameters and Methods according to their application (e.g. maintenance, diagnostics, condition monitoring). Organizes References should
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesNamespace of this specification. Table 15 - Well-Known 1:FunctionalGroupType BrowseNames BrowseName Purpose Configuration Parameters representing the configuration items of the TopologyElement . If the CurrentWrite ... AccessLevel Attribute they can be modified by Clients . Tuning Parameters and Methods to optimize the behavior of the TopologyElement . Maintenance Parameters and Methods useful for maintenance operations. Diagnostics Parameters
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices4.11 BlockTypeUnits DI Blocks BlockType is a subtype of TopologyElementType and inherits the elements for Parameters , Methods and FunctionalGroups . The BlockType is abstract. There will be no instances of a BlockType
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices5.4 ConnectionPointother components that they inherit from the TopologyElementType . The NetworkAddress FunctionalGroup includes all Parameters to specify the protocol-specific address information of the connected Device . These Parameters can be components
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.3.1 Generaloffline information. Its HasTypeDefinition Reference points to the concrete configured or identified ObjectType . All Parameters of this instance represent offline data points and reading or writing them will typically result ... online Parameter will return a proper status code (Bad_NotConnected). The transfer of information ( Parameters ) between offline nodes and the physical device in correct order is supported through TransferToDevice , TransferFromDevice
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.4.1 Definitionbased on the AddIn model specified in OPC 10000-3 . The transfer of information ( Parameters ) between offline nodes and the physical device is supported through OPC UA Methods . These Methods ... functionality. The transfer is usually terminated if an error occurs for any of the Parameters . No automatic retry will be conducted by the Server . However, whenever possible after a failure
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices6.4.4 TransferToDevice MethodTransferToDevice Method TransferToDevice initiates the transfer of offline configured data ( Parameters ) to the physical device. This Method has no input arguments. Which Parameters are transferred is based on Server -internal ... Server will reset any cached value for Nodes in the online instance representing Parameters affected by the transfer. That way the cache will be re-populated from the Device next
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesTransferFromDevice Method TransferFromDevice initiates the transfer of values from the physical device to corresponding Parameters in the offline representation of the Device . This Method has no input arguments. Which Parameters
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicestransfer and also if the previous call of FetchTransferResultData failed. MaxParameterResultsToReturn The number of Parameters in TransferResult.ParameterDefs that the Client wants the Server to return in the response. The Server ... Client is imposing no limitation. OmitGoodResults If TRUE, the Server will omit data for Parameters which have been correctly transferred. Note that this causes all good results to be released
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesTopologyElement , like Manufacturer, SerialNumber, will usually be sufficient as identification. If other Parameters or even Methods are required, all required elements shall be organized in a FunctionalGroup called Identification . Figure
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesFigure B.6 . If the Server does not implement the properties PrepareForUpdate , PowerCycle or Parameters of the SoftwareUpdateType , the associated options are not supported by the component and Client - Server interaction
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesFigure B.7 . If the Server does not implement the properties PrepareForUpdate , PowerCycle or Parameters of the SoftwareUpdateType , the associated options are not supported by the component and Client - Server interaction
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-34.2.3.4 Introduction to OPC UA DevicesDevice Object type hierarchy. Objects of the type FunctionalGroupType are used to group the Parameters and Methods of the Device into logical groups. The FunctionalGroupType and the grouping concept
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.1.1 Overviewuser specific configurations. A concrete Ctrl Configuration type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet Object
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-37.2.1 Overviewuser specific resources. A concrete Ctrl Resource type or instance may have ParameterSet , Parameters and FunctionalGroup s as defined for the TopologyElementType in OPC 10000-100 . The MethodSet Object
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.3.4 PackMLAdminObjectTypeParameter - The parameter tags associated with the local interface are typically used as parameters that are displayed or used on the unit locally, for example from an HMI. These parameters ... used to display any quality, alarm, or machine downtime parameter. The Parameters are typically limited to parameters related the unit. The length of the array is the maximum number
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.2 SetUnitMode MethodThis Method allows an OPC UA Client to change the mode of the unit. Parameters are defined in Table 23 Signature SetUnitMode( [in] Int32 RequestedMode ); Table 23 - SetUnitMode Method Parameters
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.3 SetMachSpeed Methodallows an OPC UA Client to change the speed of the machine or unit. Parameters are defined in Table 26 Signature SetMachSpeed( [in] Float RequestedMachineSpeed ); Table 26 - SetMachSpeed Method Parameters
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.4 SetProduct MethodMethod allows an OPC UA Client to change product associated with this PackML system. Parameters are defined in Table 29 . Signature SetProduct( [in] PackMLProductDataType[] Product ); Table 29 - SetProduct Method Parameters
-
OPC-30100 – OPC UA for SERCOS Devices4.2 OPC UAexpose individual elements of arrays and structures. This specification uses DataVariables to represent the Parameters of both Blocks and Devices
-
OPC-30100 – OPC UA for SERCOS Devices5.1 Generalmodel. TopologyElementType is the base ObjectType for elements in a device topology. It introduces Parameters (ParameterSet) and Methods (not shown). This specification also defines a functional grouping concept to provide
-
OPC-30110 – OPC UA for POWERLINK - POWERLINK: OPC Unified Architecture6.2.1 GeneralObject MethodSet ). As defined by the concepts of OPC 10000-100 the Parameters ( Variables ) of the ParameterSet and Methods of the MethodSet are organised in FunctionalGroups where they are referenced ... Organize-References . This concept allows splitting the Parameters into different categories, and at the same time, all Parameters are accessible under ParameterSet . Figure 16 - PowerlinkConnectionPointType
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelDevices which are of interest for engineering tools, such as IO Data , IO Channels , Parameters and Alarms . The format defined for the GSD is the GSDML
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelBase Mode Parameter (BMP) Access Access to Parameters via the "Base Mode" as described in [ PDP ], sec. 6.2.3. Requests and replies are transmitted
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelData mapping derived from the GSDML "(Virtual)SubmoduleItem/IOData" element. The "Parameters" sub-aspect contains the generic Parameter record mapping from the GSDML "(Virtual)SubmoduleItem/RecordDataList ... defined in the GSDML file. There may also exist a mapping of Parameters obtained using BMP Access . The "Alarms" sub-aspect contains the generic Alarm data mapping from
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.6 ParametersParameters Figure 14 shows the "Parameters" sub-aspect in the Functional Aspect of the Information Model. Figure 14 - Parameters Organization The GsdGenParameterVariableType Variable represents one Parameter as part ... values in the Parameter records referenced by the associated Submodule . The modelling of the Parameters as Variables allows Clients to obtain the Parameters without dissecting the Parameter record structure. Figure
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelroot container for the Objects and Variables representing a Submodule's IO Data, Parameters , Data Objects and Alarms . Moreover, information regarding the communication status of the Submodule is provided. Table
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag Methoddetails. The Configuration Object is an optional folder containing GsdGenParameterVariableType Variables representing the configuration Parameters of the Submodule . See section 6.6 for details. The <ValueVariable> Variable represents
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.7.1 StartSingleJob methodMeasIdDataType measId,[in] PartIdDataType partId,[in] RecipeIdExternalDataType recipeId[in] ProductIdDataType productId[in] BaseDataType[] parameters[out] JobIdDataType jobId[out] Int32 error); Table 100 - StartSingleJob Method Arguments Argument Description measId Identifies ... which a recipe has been prepared which is to be used by this job. parameters List of parameters for this particular execution of the recipe; number and type
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: BaseMachineryItemIdentificationType which can be specialized using MachineIdentificationType or MachineryComponentIdentificationType. The 2:Identification Object includes parameters from MachineryItemIdentificationType (which can be specialized to MachineIdentificationType or MachineryComponentIdentificationType ) defined ... MachineryLifetimeCounterType O 0:HasComponent Object 2:Maintenance 2:FunctionalGroupType O 0:HasComponent Object Parameters 0:FolderType O 0:HasComponent Object 4:MachineryBuildingBlocks 0:FolderType O 0:HasAddIn Object 4:Monitoring