Search
14 result(s) for OperationType
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing SystemsOperationType definitionThe OperationType contains objects which are necessary to operate the DosingSystem . It is formally defined in Table 4 . The top level of the OperationType describes the whole dosing ... information about the single components can be found in the ComponentsType Object . Figure 5 - OperationType Overview Table 4 - OperationType Definition Attribute Value BrowseName OperationType IsAbstract False References Node Class BrowseName
-
OPC-40082-6 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 6: Granulate Drying DevicesOperationType definitionThe ObjectType of OperationType contains components which are necessary to operate the GDD. It is formally defined in Table 3 . Figure 2 - OperationType overview Table 3 - OperationType definition ... Attribute Value BrowseName OperationType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of 0: BaseObjectType defined in OPC 10000-5 0:HasComponent Variable DeviceMappingNumber 0:UInt32 0:BaseDataVariableType
-
OPC-40092-1 – OPC UA interfaces for plastics and rubber machinery - Flexible PUR foam - Part 1: Cutting MachinesOperationType definition Provides Objects and Variables relevant for the operation of the machine and is formally defined in Table 24 . Figure 15 - Overview of OperationType Table 24 - OperationType ObjectType Definition ... Attribute Value BrowseName OperationType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseObjectType defined in OPC UA 10000-5 0:HasComponent Variable ControlVoltageSwitch 0:Boolean
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices11 Alarmsvalue of DeviceMappingNumber corresponds to the value given in the instance of the OperationType (see 9.1 ) for assigning the alarm to a device. For unique identification of the alarm event
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devicesprovide all errors via alarms in addition to the error variables included in the OperationType M A & C Alarm Server Facet (defined in OPC UA Part 7) M Table
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesHighestActiveAlarmSeverity While the HighestActiveAlarmSeverity in the OperationType (see 9.3 ) indicates the severity of the highest active alarm of the complete HRD, here the Variable indicates the severity of the highest
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicestime control and boost time stays active until the Variable ActiveSetValues given in the OperationType is changed. The provided set temperatures are related on the supported values in ActiveSetValues Variable ... OperationType (see 9.8 ). In the OperationType (see 9 ) , ActiveSetValues is writeable to switch des active set value for all zones centrally. The Variable ActiveSetValues in the HRDTemperatureType indicates the current
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices16.4 EvenHeatUpEnabledmaximum temperature difference during heat-up of all zones is defined in the OperationType with the Variable EvenHeatUpMaxTemperatureDifference
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesprovide all errors via alarms in addition to the error variables included in the OperationType M A & C Alarm Server Facet (defined in OPC UA Part 7) M Table
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems13.1 Conformance Unitsprovide all errors via alarms in addition to the error variables included in the OperationType Server OPC 40083 Tolerances Support of Status, UpperTolerance and LowerTolerance in the MonitoredParameterType and ControlledParameterType ... alarms. Server OPC 40082-3 DosingFunction Support of StartDosing, StopDosing and DosingActive in the OperationType Server OPC 40082-3 Purge Support of PurgeMode, PurgeStatus, PurgeQuantitiy and PurgeTimeout in the OperationType
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systemsconfiguration of the complete dosing system. The individual components are modelled in the OperationType with all properties required to monitor and control the operation of the system
-
OPC-40082-4 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 4: Dosing Systems7.6 OperationOperation This ObjectType contains parameters which are necessary to operate the Dosing System. The OperationType is defined in chapter
-
OPC-40082-6 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 6: Granulate Drying Devices7.4 OperationOperation This Object provides variables and methods required to operate the device. The OperationType is defined in chapter
-
OPC-40092-1 – OPC UA interfaces for plastics and rubber machinery - Flexible PUR foam - Part 1: Cutting Machines6.3 OperationOperation Provides Objects and Variables relevant for the operation of the machine. The OperationType is defined in chapter