Search
46 result(s) for Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems1 Scopedescription of its components regarding a Compressed Air System. Main scope of this specification is the communication between the Main Control System and the higher-level manufacturing system(s). More
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.2 CASPartNote 1 to entry: CASParts defined in this specification are: Airnet , all Components , Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.4 Compressed Air SystemComponents and at least one Airnet , and is commonly equipped with one Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.10 Integrated [Component]Integrated [Component] A Component is Integrated if the Main Control System has control over the generation or treatment of compressed air. Note 1 to entry: A compressor is Integrated ... Main Control System has control over the loaded state. Note 2 to entry: The Main Control System can switch a Component between the two states Integrated and Isolated
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.11 Isolated [Component]Isolated [Component] A Component is Isolated if the Main Control System has no control over the generation or treatment of compressed air. Note 1 to entry: A Component is Isolated ... Main Control System does not control the loaded state. Note 2 to entry: The Main Control System can switch a Component between the two states Integrated and Isolated
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.14 Quantitymeasurements performed by a sensor, or calculations performed by a CASPart or the Main Control System to simulate a physical measurement. Note 1 to entry: A physical quantity ... integrated into the CASPart . Note 3 to entry: A calculation performed on the Main Control System which is used by a Component shall be assigned to that Component . EXAMPLE
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.16 Unavailable [Compressor]compressor is Unavailable if it cannot be Integrated and controlled by the Main Control System . Note 1 to entry: The Main Control System cannot switch a compressor from Unavailable
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsfilters, air quality monitoring units etc., it is commonly also equipped with a Main Control System . The latter is used to control and/or monitor the connected devices and gather information ... Main Control System would be possible. The variety of Compressed Air System is rather wide. It could be e.g. two compressors and a Main Control System and a basic compressed
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemscases Below is a list of possible use cases a Main Control System may implement fully or partly
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsmanagement, e.g. Documentation Management, Energy Management and Maintenance Management. For this purpose, the Main Control System shall provide properties for asset identification. In addition to nameplate information of the CASParts
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsoperator's maintenance management application, the Main Control System should provide Compressed Air System specific maintenance properties. To support asset monitoring, the Main Control System collects and analyzes operational ... wear). Since plant operators require a generalized health status of plant assets, the Main Control System shall provide a generalized Compressed Air System health status, based on the NAMUR NE107
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsintegrate a Compressed Air System into the operator´s energy management, the Main Control System should provide energy-related information about the Compressed Air System and its installed CASParts ... able to trigger analyses of the Compressed Air Systems energy performance within the Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems5.5 OperationControl System ) the generation of compressed air. It should be possible to select from different operating modes for the Compressed Air System . For the operators / integrators process monitoring, the Main ... compressed air by accessing operational data of the Compressed Air System via the Main Control System . The Main Control System shall provide actual values of e.g. pressure, flow, inlet / outlet
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems6.3 Airnet Examplesconnected to the red Airnet and treated as such. The Main Control System is not a part of the Airnet . Figure 8 - Simple Airnet Figure 9 shows a Compressed ... blue box are connected to the blue Airnet and treated as such. The Main Control System is not a part of any Airnet . Figure 9 - Two Simple Airnets Figure
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems6.4 IdentificationObject of the CASIdentificationType which uses the Interface ITagNameplateType and its Properties . The Main Control System is identified by an Identification Object of the MachineryComponentIdentificationType. Components are identified ... System Charging system ChargingSystem ChargingSystems Compressor Compressor Compressor Compressors Condensate Drain Condensate drain CondensateDrain CondensateDrains Condensate Separator Condensate separator CondensateSeparator CondensateSeparators Converter Converter Converter Converters Cooling System Cooling system CoolingSystem
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsprovides both Objects for Quantities and FunctionalGroups for its Airnets , Components , and the Main Control System . It is illustrated in Figure 16 and formally defined in Table 11 . Figure ... Compressed Air System . The optional Object MCS is the representation of the Main Control System . The InstanceDeclarations of the CASType have additional Attributes defined in Table 12 . Table 12 - CASType
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsMCSType ObjectType DefinitionThe MCSType is the representation of a Main Control System and provides both Objects for Quantities and FunctionalGroups . It is illustrated in Figure 21 and formally defined ... Analyses provides Objects and Methods for analyses that can be invoked on the Main Control System . The optional FunctionalGroup Configuration provides Objects and Methods for configuring the behavior
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsprovides Objects and Methods that are used for invoking an analysis on the Main Control System and is formally defined in Table 53 . Table 53 - AnalysisType Definition Attribute Value BrowseName ... optional Object OutputFile shall contain the result of an analysis if the Main Control System can provide a file in the AddressSpace of the OPC UA Server . If not, this
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.25.1 TriggerTrigger The Method Trigger is used to trigger an analysis on the Main Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsObjectType Definition The AnalysesType provides O bjects for invoking analyses performed by the Main Control System and is formally defined in Table 56 . Such analyses may be performed on Compressed ... results of analyses performed by the manufacturer, automatically recurring analyses performed by the Main Control System , or other analyses that do not require a trigger and an output file
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsbehavior of a CASPart . This specification defines configuration properties for Airnets and the Main Control System . There are no configuration properties defined for Components . It is formally defined in Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsOperatingProfiles provides manufacturer or system specific operating profiles of an Airnet . On the Main Control System , operating profiles are stored as sets of parameters for parameterizing the behavior
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsdisplay the ethernet communication settings of the OPC UA connection point of the Main Control System . The optional Object ConfigurationFile of the FileType shall be used to store the Main ... AddressSpace . This configuration file may be uploaded to or downloaded from the Main Control System using the described Methods. It should be a persistent representation of the currently active configuration
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.1 LoadConfigurationFileLoadConfigurationFile is used to load the configuration file stored in ConfigurationFile into the Main Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.2 SaveConfigurationFileSaveConfigurationFile The Method SaveConfigurationFile is used to save the current configuration of the Main Control System to the file stored in ConfigurationFile. The signature of this Method is specified below
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsCommunicationSettingsType ObjectType Definition The CommunicationSettingsType provides Variables for the communication settings of the Main Control System and is formally defined in Table 68 . Table 68 - CommunicationSettingsType Definition Attribute Value BrowseName
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemscalculated by the OPC UA Server but may be calculated by the Main Control System . The definition of the KPIs is intentionally flexible so that the KPIs can be adapted
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.49.1 DrainTestDrainTest is used to trigger a test of the condensate drain via the Main Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems8.17 OperatingStateEnumstate machine does not imply the actual function or state machine in the Main Control System . It serves as an example of how the actual state machine may function. Figure
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsstate machine does not imply the actual function or state machine in the Main Control System . It serves as an example of how the actual state machine may function. Figure
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsstate machine does not imply the actual function or state machine in the Main Control System . It serves as an example of how the actual state machine may function. Figure
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsstate machines do not imply the actual functions or state machines in the Main Control System . It serves as an example of how the actual state machines may function. Figure
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.2 CAS Base Analyses Server FacetBase Analyses Server Facet This Facet defines the elements for a Main Control System that provides prefabricated or pre-parameterized analyses on Compressed Air System or Airnet level. Although both
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAdvanced Analyses Server Facet This Facet defines the elements for a Main Control System that provides parameterizable analyses on Compressed Air System or Airnet level and the possibility to store
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsBase Configuration Server Facet This Facet defines the elements for a Main Control System that provides its OPC UA communication settings and the component class for Components . Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAdvanced Configuration Server Facet This Facet defines the elements for a Main Control System whose configuration can be stored as a file in the OPC UA AddressSpace . Table
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsBase Maintenance Management Server Facet This Facet defines the elements for a Main Control System that provides a health state and statistics for CASParts . Table 168 - CAS Base Maintenance Management
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAdvanced Maintenance Management Server Facet This Facet defines the elements for a Main Control System that provides events and conditions. Table 169 - CAS Advanced Maintenance Management Server Facet Group Conformance
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsEnergy Management Server Facet This Facet defines the elements for a Main Control System that provides necessary Variables and their historization for energy management applications. Table 170 - CAS Energy Management
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.9 CAS Operation Server FacetOperation Server Facet This Facet defines the elements for a Main Control System that provides necessary Variables for operational applications. Table 171 - CAS Operation Server Facet Group Conformance Unit / Profile
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.10 CAS Base Server ProfileBase Server Profile This Profile defines the elements for a Main Control System that supports base functionality. Table 172 - CAS Base Server Profile Group Conformance Unit / Profile Title
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.11 CAS Advanced Server ProfileAdvanced Server Profile This Profile defines the elements for a Main Control System that supports advanced functionality. Table 173 - CAS Advanced Server Profile Group Conformance Unit / Profile Title
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsMaintenance Management Server Profile This Profile defines the elements for a Main Control System that supports the maintenance management use case. Table 174 - CAS Maintenance Management Server Profile Group Conformance
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.13 CAS Energy Management Server ProfileEnergy Management Server Profile This Profile defines the elements for a Main Control System that supports the energy management use case. Table 175 - CAS Energy Management Server Profile Group Conformance
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.14 CAS Dynamic Server ProfileDynamic Server Profile This Profile defines the elements for a Main Control System that supports node manipulation during the runtime of the Server . Table 176 - CAS Dynamic Server Profile Group
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.15 CAS Full Server ProfileFull Server Profile This Profile defines the elements for a Main Control System which supports all ConformanceUnits . Table 177 - CAS Full Server Profile Group Conformance Unit / Profile Title