OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.6 BrowseResultBrowse operation. statusCode StatusCode The status for the BrowseDescription. This value is set to Good if there are still references to return for the BrowseDescription . continuationPoint ContinuationPoint A Server defined
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.4.2.13 DiagnosticInfoInnerStatusCode StatusCode A status code provided by an underlying system. The default value is Good . It is not encoded if the value is Good . InnerDiagnosticInfo DiagnosticInfo Diagnostic info associated with
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsA.2 Status Codesseverity associated with a particular code is specified by the prefix ( Good , Uncertain or Bad ). The CSV released with this version of the standards can be found here: https://reference.opcfoundation.org
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypeStatusCodes defined in 10000-8 as well as Good , Uncertain and Bad as defined in 10000-4 . These StatusCodes are similar to but slightly more generic than the description ... status information to these codes. A Server that supports no quality information shall return Good . This quality can also reflect the communication status associated with the system that this value
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Servicesprevious StartSigningRequest or StartNewKeyPairRequest . The following results are possible: If FinishRequest returns a Good result, the Method returns the signed Certificate and optionally the private key for the StartNewKeyPairRequest case
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.5.2 CloseAndUpdateorder of the array shall match the targets array. If any element is not Good then then no changes are applied and the Method return code is Uncertain . NewVersion ... record was not found. Bad_EntryExists Another record with the same name was found. Good_EntryInserted A new record was created successfully, Good_EntryReplaced An existing record was updated successfully
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.9 ApplyChangesthere is an active transaction, however, no changes are pending the result is Good and the transaction is closed. When a Server Certificate or TrustList changes active SecureChannels
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.10.17 TransactionDiagnosticsTypetransaction has started but not completed. If the transaction has completed the status is Good and the value is the StatusCode that was returned from the ApplyChanges Method
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.14 RangeRange Aggregate defined in Table 62 finds the difference between the maximum and minimum Good raw values in the interval. If only one Good value exists in the interval ... range is zero. Note that the range is always zero or positive. If non-Good values are ignored when finding the minimum or maximum values or if Bad values exist
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.27 DeltaDelta Aggregate defined in Table 75 retrieves the difference between the earliest and latest Good raw values in the interval . The Aggregate is negative if the latest value is less ... than the earliest value. The status is Uncertain_DataSubNormal if non-Good values are skipped while looking for the first or last values. The status is Good otherwise. The status
-
OPC-10000-13 – OPC Unified Architecture - Part 13: Aggregates5.4.3.31 DurationGoodDurationGood The DurationGood Aggregate defined in Table 79 divides the interval into regions of Good and non-Good data. Each region starts with a data point in the interval ... that data point is Good the region is Good. The Aggregate is the sum of the duration of all Good regions expressed in milliseconds. The status of the first region
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.4.2 DataSetFieldContentMaskValue Status (a) Value Value Status (a) Header Status Value Status (a) Value 1 Good_* Variant Value 1 N/A Good Value 1 Good Value 1 Uncertain_* Value 1 Uncertain ... Good Value 1 (b) Uncertain_* (b) Null Bad_* Bad_* (c) Good Null Bad_* (c) Value 1 Good_* DataValue Value 1 Good_* Good Value 1 Good_* Value 1 Uncertain_* Value
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serialization4.5 General FeaturesSerializedData Variable to 1. Writing of the SerializationValue yields one Result Code which is Good only if all original Values in the SerializationScope are successfully updated, otherwise the Result Code
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serializationargument. This array is empty if the Method execution was successful ( Method result code Good ). Possible result values. 0 - OK -1 - E_InvalidProperty - the Property name is unknown ... defined in Table 5 . The configuration is applied if a result code with severity Good is returned. Otherwise, no Property is changed. Table 5 - Possible Method Result Codes Result Code
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationPubSub scenario. If the StatusCode of the "MeasurementY1" Variable Value is Good , an empty "Status" is generated by the encoder. If the StatusCode is Uncertain
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.3 BaseLogEventTypestatus related to the Node generating the LogRecord . It may be set to Good or Bad with no subcode, if no specific error is being reported. This field
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpossible Results StatusCodes are formally defined in Table 82 . The Results array shall contain Good for any ConnectionConfigurationSet that was successfully updated. Table 82 - Results StatusCodes ResultCode Description Good
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelFunctionalEntityNode . If CommandMask VerifyFunctionalEntityCmd is not set, it shall be set to Good . VerificationVariablesErrors 0:StatusCode[] Variables errors related to the identity check of the FunctionalEntityNode . If CommandMask VerifyFunctionalEntityCmd ... communication model. If CommandMask SetCommunicationConfigurationCmd is not set, it shall be set to Good . EnableCommunicationResult 0:StatusCode Status Code related to the overall enabling of the communication model. If CommandMask
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelsteps. If the value of ErrorEndpoint1 is NoError, this field shall be set to Good . ErrorEndpoint2 4:FxErrorEnum An enumeration that describes an error related to Endpoint2 in the Connection ... steps. If the value of ErrorEndpoint2 is NoError, this field shall be set to Good . The following rules apply to updating the LastActivity and all ConnectionEndpoint -related fields ( ErrorEndpoint1
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelthis DataType is converted to an Object , the ProcessingResult shall be set to Good . The ConnectionConfigurationConfDataType is formally defined in Table F.3 . Table F.3 - ConnectionConfigurationConfDataType structure Name Type Description Optional
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicscomputed and the program is currently running or paused, the StatusCode should be Good . This indicates that the estimated runtime is available and the program is in progress
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.12.1 Start Methodstate machine. If the method is successfully called, the method should return with a Good or Uncertain result code. The Start Method allows an authorized Client to command the system ... Table 52 Table 52 - Method Result Codes (defined in Call Service) Result Code Description Good The system level operation succeeded Uncertain The value is uncertain. A concrete reason is defined
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management8.4.3 ProductionJobTypevalue of the Name Property of the respective ProductionPartSetType instance. PartsGood indicates how many good parts have been completed in the current job including all runs. A part is counted ... subsequent processing steps (on different machines), even if a part was counted as good. In this case, the data on the OPC UA Server are not changed retrospectively. If individual
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management12.6 PartQualitymachine tool is not able to give a statement about the part quality. Good 1 The part quality is determined good. Bad 2 The part quality is determined bad. NotYetMeasured ... PartQuality will still be determined in the machine tool to be either Good or Bad . WillNotBeMeasured 4 The machine tool will not give a statement about the part quality
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management14.1 ConformanceUnitscounter shall be identical to the number of PartType instances with PartQuality set to Good , CapabilityUnavailable or WillNotBeMeasured . Server MachineTool Monitoring MaintenanceMode Instances of MachineToolType shall provide the SubStateMachine Maintenance