Search
27 result(s) for Facets
-
OPC-10000-7 – OPC Unified Architecture - Part 7: Profiles3.1.5 Facetspecific feature that a Server or Client may require Note 1 to entry: Facets are typically combined to form higher-level Profiles . The use of the term Facet
-
OPC-10000-7 – OPC Unified Architecture - Part 7: ProfilesProfile Categories Category Description Application Profiles Application level Profiles represent a collection of Facets necessary to build a functional OPC UA Application.They specifically include Transport Profiles and generally also Security
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.3.3 SPI of SafetyProviderimplemented. 0: Server for OPC UA Client/Server communication is not implemented. The corresponding Facets are SafetyProviderServer and SafetyProviderServerMapper. SafetyPubSubImplemented Boolean 0x0 or 0x1 n.a. R This read-only parameter indicates ... PubSub communication is implemented. 0: OPC UA PubSub communication is not implemented. The corresponding Facets are SafetyProviderPubSub and SafetyProviderPubSubMapper. Figure 9 - Example combinations of SIL capabilities The constant SafetyProviderLevel determines
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.4.4 SPI of the SafetyConsumerPubSub communication is implemented. 0: OPC UA PubSub communication is not implemented. The corresponding Facets are SafetyConsumerPubSub and SafetyConsumerPubSubMapper
-
OPC-10000-17 – OPC Unified Architecture - Part 17: Alias NamesNote: Support for remote Server TargetNodes is optional, but may be required for some Facets Uncertain_ReferenceOutOfServer For an AliasName that referenced a node in another Server , the target node
-
OPC-10000-24 – OPC Unified Architecture - Part 24: Scheduler9.2.2.1 OverviewOverview The following sections specify the Facets available for Servers that implement the Scheduler companion specification. Each section defines and describes a Facet or Profile
-
OPC-10000-24 – OPC Unified Architecture - Part 24: Scheduler9.2.3.1 OverviewOverview The following tables specify the Facets available for Clients that implement the Scheduler companion specification
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model4.1 Overviewillustrated types/instances are required for an implementation and are covered by separate ConformanceUnits and Facets . Figure 2 - Overview of LogObject Information Model
-
OPC-10000-80 – OPC Unified Architecture - Part 80: UAFX Overview and Concepts6.5 ProfilesAutomationComponents will support one or more Profiles and any or all of its optional Facets
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelmodel are expected to provide the described functionality. OPC UA FX Facets like Motion and IO could provide their own derived types. Creating an Information Model for a new vendor
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelpush model. An AutomationComponent indicates support for the pull model by the Facets it includes in its ServerProfileArray (" http://opcfoundation.org/UA-Profile/Publisher/MessageSecurity " for a Publisher and " http://opcfoundation.org
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles4.1 GeneralGeneral This document adds ConformanceUnits , ConformanceGroups , Profiles , and Facets grouping OPC UA FX features to the Profile Model defined
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX ProfilesContains one or more Bridge Components , each supporting one or more of the following Facets : Base Bridge Component Facet, Advanced Bridge Component Facet, Full Bridge Component Facet Rules for future ... changes of this CU: 1) All included facets must be based on a common Base Bridge Component Facet. 2) Facets must not be mutually exclusive. 3) A Full Bridge Component
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.5 ApplicationsApplications Figure 1 illustrates the Profiles and Facets that make up a UAFX Controller application. Figure 1 - Structure of the UAFX Profiles
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.2.1 OverviewOverview This clause defines Facets for the UAFX Information Model illustrated in Figure 2 , Figure 3 , and Figure 4 . Figure 2 - Structure of AutomationComponent related Facets Figure 3 - Structure ... FunctionalEntity related Facets Figure 4 - Structure of Asset related Facets
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.3.6 IA-station Facetmandates an End Station Component Facet and adds the option to include Bridge Component Facets (via the UAFX EthernetIAStation ContainsBridge ConformanceUnit ). It also adds functionality for Topology Discovery , Remote Management
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.1 OverviewFigure 8 , and Figure 9 illustrate the structure of UAFX Controller Profiles and Facets . Figure 6 - Structure of the UAFX Server Profile Figure 7 - Structure of the UAFX ConnectionManager Facet
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.4.10 UAFX Controller 2024 ProfileUAFX Controller 2024 Profile. This Profile is a collection of Profiles and Facets necessary to build a functional UAFX Controller , including a ConnectionManager . This Profile supersedes the UAFX Controller
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles6.6.5.1 OverviewOverview This clause defines Profiles and Facets for the UAFX OfflineEngineering illustrated in Figure 12 , Figure 11 , and Figure 12 . Figure 10 - Structure of the OfflineEngineering Descriptor Profile Figure
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics15.2.2.1 OverviewOverview The following sections specify the Facets available for Servers that implement the Asset Management Basics companion specification. Each section defines and describes a Facet or Profile
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics15.2.3.1 OverviewOverview The following tables specify the Facets available for Clients that implement the Asset Management Basics companion specification
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping7.2.2.1 OverviewOverview The following sections specify the Facets available for Servers . Each section defines and describes a Facet or Profile
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation8.2.2.1 OverviewOverview The following sections specify the Facets available for Servers that implement the Industrial Automation companion specification. Each section defines and describes a Facet or Profile
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automationcalibration targets, one-time calibration targets and dynamic calibration targets. Table 62 defines contained Facets of the Facet . Table 68 - IA CT Reusable Calibration Target Handling Server Facet Group Conformance
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation8.2.3.1 OverviewOverview The following sections specify the Facets available for Clients that implement the Industrial Automation companion specification. Each section defines and describes a Facet or Profile
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location9.2.2.1 OverviewOverview The following sections specify the Facets available for Servers that implement the RSL companion specification. Each section defines and describes a Facet or Profile
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location9.2.3.1 OverviewOverview The following tables specify the Facets available for Clients that implement the Relative Spatial Location companion specification