Search
17 result(s) for Enabled
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions4.2 Conditionsvendors or other standardisation groups. The primary states of a Condition are disabled and enabled. The Disabled state is intended to allow Conditions to be turned off at the Server ... below the Server (in a device or some underlying system). The Enabled state is normally extended with the addition of sub-states. Figure 1 - Base Condition state model A transition
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & ConditionsCondition instances in the AddressSpace Because Conditions always have a state ( Enabled or Disabled ) and possibly many sub-states it makes sense to have instances of Conditions present
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.2 ConditionTypeflag when SupportsFilteredRetain flag is set to True. EnabledState indicates whether the Condition is enabled. EnabledState/Id is True if enabled, False otherwise. EnabledState/TransitionTime defines when the EnabledState last changed. Recommended ... This includes all ConditionBranches if any branches exist. When the Condition instance enters the enabled state, the Condition shall be evaluated and all of its Properties updated to reflect
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Servicesdefined: ServiceStatus Description Bad_OutOfService Communication was not attempted by the Server because Enabled is FALSE. Bad_IdentityTokenRejected Communication failed because the KeyCredentials are not valid. Bad_NoCommunication Communication failed
-
OPC-10000-17 – OPC Unified Architecture - Part 17: Alias NamesServers to direct the notification message to a specific GDS or aggregating Server . The Enabled that is associated with the PubSubConnection for the published messages . This flag can be used
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.9.2 PubSubdescribed in 6.2.4.3.11 . The SetCommunicationConfigurationCmd will apply the PubSubConfiguration , including the values of all Enabled flags for the configuration elements. Depending on the values of the Enabled flags, this ... result in overall enabled PubSub communication without passing the EnableCommunicationCmd or parts of the PubSub communication being enabled while others are disabled. The EstablishConnections implementation shall create the ToDataSetReader
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.7.5.3.1 ActionEstablishConnectionsEnabled / ActionEstablishConnectionsDisabled / ActionEstablishConnectionscommunication model and include EnableCommunicationCmd in the command sequence. A disabled communication model has Enabled flags set to FALSE for all DataSetReader and DataSetWriter configuration elements and to TRUE ... communication model and omit EnableCommunicationCmd from the command sequence. A disabled communication model has Enabled flags set to FALSE for all DataSetReader and DataSetWriter configuration elements and to TRUE
-
OPC-30020 – MDIS OPC UA Companion SpecificationHasComponent Variable Warning 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable Enabled 0:Boolean 0:BaseDataVariableType O, RO 0:HasProperty Variable TagId 0:String 0:PropertyType ... object, true if any warnings exist. A warning does not require immediate operator action. Enabled - This Variable is set as enabled (true) by default. When disabled the Object will
-
OPC-30020 – MDIS OPC UA Companion Specificationreported by the SPCS. An active interlock. The choke is in the disabled state Enabled - This Boolean reflects if the choke is available for control. The behaviour follows the MDISBaseObjectType
-
OPC-30020 – MDIS OPC UA Companion Specificationreported by the SPCS. An active interlock. The choke is in the disabled state Enabled - This Boolean reflects if the choke is available for control. The behaviour follows the MDISBaseObjectType
-
OPC-30020 – MDIS OPC UA Companion Specificationequipment by the SPCS (see 8.1.5 for a description of the possible enumerations). Enabled - This Boolean reflects if the valve is available for control. The behaviour follows the MDISBaseObjectType. Position
-
OPC-30020 – MDIS OPC UA Companion Specificationreported by the SPCS. An active interlock. The CIMV is in the disabled state Enabled - This Boolean reflects if the CIMV is available for control. The behaviour follows the MDISBaseObjectType
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerWarning Support the Warning flag Server MDIS Base WarningCode Support WarningCodes Server MDIS Base Enabled Support the Enabled flag and the EnableDisable Method to toggle the flag. Server MDIS Base
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.3 ClientMDIS Client Base WarningCode The Client displays or reports WarningCode . Client MDIS Client Base Enabled The Client makes use of and displays or reports the Enabled flag and the EnableDisable
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical IntegrationUnified Architecture 0:HasProperty Variable Name 0:String 0:PropertyType M 0:HasComponent Variable Enabled 0:Boolean 0:BaseDataVariableType M 0:HasComponent Variable Active 0:Boolean 0:BaseDataVariableType M Conformance ... ProtectiveStopFunctionType provides a manufacturer-specific protective stop function identifier within the safety system. The Enabled variable is TRUE if this protective stop function is currently supervising the system, FALSE otherwise
-
OPC-40020-1 – OPC UA for Cranes and Hoists - Part 1: Base Model Motion Devices System7.6.1 OverviewHasComponent Variable DirPlusStop 0:Boolean 0:BaseDataVariableType O, RO 2:ParameterSet 0:HasComponent Variable Enabled 0:Boolean 0:BaseDataVariableType O, RO 2:Operational 0:Organizes Variable Active 0:Boolean ... Organizes Variable DirPlusStop 0:Boolean 0:BaseDataVariableType O, RO 2:Operational 0:Organizes Variable Enabled 0:Boolean 0:BaseDataVariableType O, RO The Active variable provides information about the protective function
-
OPC-40450-1 – OPC UA for Joining Systems - Part 1: BaseHasComponent Variable Connected 0:Boolean 0:BaseDataVariableType O, RO Parameters 0:HasComponent Variable Enabled 0:Boolean 0:BaseDataVariableType O, RO Parameters 0:HasComponent Variable IOSignals SignalDataType[] 0:BaseDataVariableType ... asset in a joining system . It has the following parameters described below: Enabled indicates if a given asset is enabled or disabled. It can change by the EnableAsset method