Search
38 result(s) for DataValue
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.11.2.2 ParametersResponse responseHeader ResponseHeader Common response parameters (see 7.33 for ResponseHeader definition). results [] DataValue List of Attribute values (see 7.11 for DataValue definition). The size and order of this list matches
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.11.2.4 StatusCodesStatusCodes Table 49 defines values for the operation level statusCode contained in the DataValue structure of each results element. Common StatusCodes are defined in Table 179 . Table 49 - Read Operation
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.11.4.2 ParametersindexRange is provided and writing of indexRange is not possible for the Node . value DataValue The Node 's Attribute value (see 7.11 for DataValue definition). If the indexRange parameter
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.1.5 Queue parametersdiscard policies when the MonitoredItem is created. If a Notification is discarded for a DataValue and the size of the queue is larger than one, then the Overflow bit (flag ... InfoBits portion of the DataValue statusCode is set. If discardOldest is TRUE, the oldest value gets deleted from the queue and the next value in the queue gets the flag
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.2.2 ParametersWhen monitoring Events , this applies only to Event fields that are of type DataValue . itemsToCreate [] MonitoredItem CreateRequest A list of MonitoredItems to be created and assigned to the specified Subscription
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.13.3.2 ParametersWhen monitoring Events , this applies only to Event fields that are of type DataValue . itemsToModify [] MonitoredItemModifyRequest The list of MonitoredItems to modify. This structure is defined in-line with
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.21 MonitoringParametersqueue overflow, the Overflow bit (flag) in the InfoBits portion of the DataValue statusCode is set in the new value. The following values have special meaning for event monitored items
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesClient -supplied handle for the MonitoredItem . The IntegerId type is defined in 7.19 Value DataValue The StatusCode , value and timestamp(s) of the monitored Attribute depending on the sampling ... size of the queue is larger than one, the Overflow bit in the DataValue InfoBits of the statusCode is set. DataValue is a common type defined in 7.11 . diagnosticInfos [] DiagnosticInfo
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.38.1 GeneralNotUsed 00 The info bits are not used and shall be set to zero. DataValue 01 The StatusCode and its info bits are associated with a data value returned from ... describes the structure of the InfoBits when the Info Type is set to DataValue (01). Table 177 - DataValue InfoBits Info Type Bit Range Description LimitBits 8:9 The limit bits
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Modelnumber of disabled monitored items of the subscription. monitoringQueueOverflowCount UInt32 The number of DataValue Notifications that have been discarded for all MonitoredItem s when the queue size of a MonitoredItem
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.1.4 DateTimesupported precision. All DevelopmentPlatforms shall support a precision of at least 1 ms. The DataValue built-in type adds additional fields for Picoseconds. If a DevelopmentPlatform cannot support the full
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.1.9 Variantreturned in instances of DataValues . Therefore, the DataType of an Attribute cannot be a DataValue . Variants can contain DataValue when used in other contexts such as Method Arguments or PubSub ... Messages . The Variant in a DataValue cannot, directly or indirectly, contain another DataValue . ExtensionObjects and Variants allow unlimited nesting which could result in stack overflow errors even if the message
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.2.2.17 DataValueDataValue A DataValue is always preceded by a mask that indicates which fields are present in the stream. The fields of a DataValue are described in Table 27 . Table
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.3.1.18 DataValueDataValue A DataValue value is encoded as a xs:complexType with the following XML schema: <xs:complexType name="DataValue"> <xs:sequence> <xs:element
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.4.2.18 DataValueDataValue DataValue values shall be encoded as a JSON object with the fields shown in Table 42 . The DataValue adds additional fields to a Variant (see 5.4.2.17 ). Table 42 - JSON ... Object Definition for a DataValue Name Data Type Description UaType Byte See the UaType field in the Variant . Value * See the Value field in the Variant . Dimensions UInt32
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionssame time that would be returned from the Read Service inside the DataValue structure for the ConditionVariable Value Attribute
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access3.1.8 RawDataHistoricalDataNode Note 1 to entry: The data can be all data collected for the DataValue or it can be some subset of the data depending on the historian
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.2.2 Read Event functionalityNoData . When reading Events, TimestampsToReturn only applies to Event fields that are of type DataValue . If the requested TimestampsToReturn is not supported for an Event field then the returned value
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.5.2.4 Read modified functionalityNoData . When reading Events, TimestampsToReturn only applies to Event fields that are of type DataValue . If the requested TimestampsToReturn is not supported for an Event field then the returned value
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical Access6.9.1 OverviewHistoricalDataNodes The Variable 's value is represented by a composite value defined by the DataValue data type. UpdateDataDetails Replace data This function replaces existing values into the history database ... HistoricalDataNodes . The Variable 's value is represented by a composite value defined by the DataValue data type. UpdateDataDetails Update data This function inserts or replaces values into the history database
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.3.2 DataSetMessage fieldvalue like status and timestamp. A DataSet field can be represented as a DataValue , as a Variant or as a RawData in the DataSetMessage field. The representation depends ... defined in 6.2.4.2 and the message mappings defined in 7.2 . The representation as a DataValue is used if value, status and timestamp are included in the DataSetMessage . The representation
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.3.7.1 PublishedDatavalue that is included in the DataSet if the StatusCode of the DataValue is Bad. In this case the StatusCode is set to Uncertain_SubstituteValue. This Value shall match ... DataType that matches the ConfigurationVersion . If the SubstituteValue is Null, the StatusCode of the DataValue is processed. The handling of the SubstituteValue is defined in 6.2.11 . MetaDataProperties QualifiedName [ ] This parameter
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.4.2 DataSetFieldContentMaskValues Value Bit No. Description DataSet fields can be represented as RawData, Variant or DataValue as described in 5.3.2 . If none of the bits are set, the fields are represented ... bits 0 to 4 is set, the fields are represented as DataValue . StatusCode 0 The DataValue structure field StatusCode is included in the DataSetMessage s. If this
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.9.5 DataSetFieldContentMaskDataSetFieldContentMask The parameter DataSetFieldContentMask with DataType DataSetFieldContentMask indicates the fields of a DataValue included in the DataSetMessages . The parameter shall be ignored for heartbeat messages. The DataSetFieldContentMask DataType is defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.5.4 DataSetMessage headerDataType if the status of the field is Bad. The Variant can contain a DataValue with the value and the statusCode if the status of the field is Uncertain ... RawData Field Encoding The RawData field encoding is defined in 7.2.4.5.11 . 10 DataValue Field Encoding The DataSet fields are encoded as DataValue . This option is set if the DataSet
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.5.11 RawData field encodingStructure fields shall not have the builtInType NodeId , ExpandedNodeId , QualifiedName , LocalizedText , XmlElement, DiagnosticInfo or DataValue . RawField encoding shall only be applied to Data Key Frame DataSetMessages . Structure DataTypes shall
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.4.1 Message contentevent", only Variant or RawData encoding shall be allowed. If bits for DataValue encoding are set, the Variant encoding shall be used. This value is always present. All fields ... DataSetMessage fields are encoded as Variant . Otherwise the fields are encoded as DataValue . If the MessageType is "ua-event", the DataSetFieldContentMask shall be 0x0 or 0x20
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubother ValueRank is mentioned in the description. Table 187 provides examples of DataValue VerboseEncoding field encoding for RawData=FALSE. For RawData=TRUE the UaType and UaTypeId fields are skipped ... reduce the string length for readability of the examples. Table 187 - DataSet field DataValue VerboseEncoding examples Description DataType RawData = FALSE Simple scalar Int32 Int32 { "Value": 1234, "SourceTimestamp
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.6.2 ActionRequestDataSetFieldContentMask. Only Variant or RawData encoding shall be allowed. If bits for DataValue encoding are set, the Variant encoding shall be used. The encoding rules defined in 7.2.5.4 for DataSetMessages ... also apply to the ActionRequest message. The DataValue encoding shall not be used in ActionRequest message. The RawData flag shall be FALSE for ActionRequest messages
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.6.3 ActionResponseDataSetFieldContentMask. Only Variant or RawData encoding shall be allowed. If bits for DataValue encoding are set, the Variant encoding shall be used. The value shall be present. The encoding rules ... defined in 7.2.5.4 for DataSetMessages also apply to the ActionResponse message. The DataValue encoding shall not be used in ActionResponse message. The RawData flag shall be FALSE for ActionResponse messages
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.7 PubSub DataSetsstatus to be sent in the case of a bad status) or a DataValue (value, status, and timestamps) encoding. Figure E.18 - Fixed DataSetMessage Other PubSub Profiles can include a dynamic
-
OPC-30130 – OPC UA for Control & Communication System Profile(for Machine)6.4.7.2 Preset label CSPP elementfield (bit 30 and bit 31) of the statusCode element of a value as DataValue DataType *1 from the Service return values When the value acquired from the machine ... Property . 4. P_ChangeDate "sourceTimestamp" member of a value as DataValue DataType *1 from the Service return values Maps the item value acquired from the machine
-
OPC-30142 – OPC UA for PROFINET Remote IOValue of Process Values , the Server shall set the StatusCode member of the DataValue structures returned by the Read Service and the Publish Service consistent with the Process Value Qualifier
-
OPC-30142 – OPC UA for PROFINET Remote IOTypeDefinition Other Subtype of the BaseDataVariableType defined in OPC 10000-5 . 0:HasComponent Variable DataValue 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable QualifierValue 0:Byte RioPaProcessValueQualifierVariableType ... Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value as transmitted in the telegram signal. The Value of the QualifierValue Variable contains the status information as transmitted
-
OPC-30142 – OPC UA for PROFINET Remote IOTypeDefinition Other Subtype of the BaseDataVariableType defined in OPC 10000-5 . 0:HasComponent Variable DataValue 0:Boolean 0:BaseDataVariableType O, RO 0:HasComponent Variable QualifierValue 0:Boolean RioFaProcessValueQualifierVariableType ... Conformance Units PNRIO Channel Objects The DataValue Variable contains the Process Value bit as transmitted in the telegram signal. The Value of the QualifierValue Variable contains the qualifier
-
OPC-30142 – OPC UA for PROFINET Remote IOTypeDefinition Other Subtype of the BaseDataVariableType defined in OPC 10000-5 . 0:HasComponent Variable DataValue 0:Number 0:BaseAnalogType O, RO 0:HasComponent Variable QualifierValue 0:Byte RioPaProcessValueQualifierVariableType ... Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process Value as transmitted in the telegram signal. The optional EngineeringUnits Property of the DataValue Variable shall be provided
-
OPC-30142 – OPC UA for PROFINET Remote IOTypeDefinition Other Subtype of the BaseDataVariableType defined in OPC 10000-5 . 0:HasComponent Variable DataValue 0:Number 0:BaseAnalogType O, RO 0:HasComponent Variable QualifierValue 0:Boolean RioFaProcessValueQualifierVariableType ... Conformance Units PNRIO Channel Objects The DataValue Variable contains the analog Process Value as transmitted in the telegram signal. The optional EngineeringUnits Property of the DataValue Variable shall be provided
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modeldata is provided (see GsdGenIoChannelQualityType ), the Server shall set the StatusCode member of the DataValue structures returned by the Read Service and the Publish Service consistent with the content