Search
21 result(s) for Data
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappingscheck the expiry times for Certificates or CRLs . In addition, incorrect Timestamps on Data and Events could create interoperability issues. The Network Time Protocol ( NTP ) provides a standard
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.4.1 OverviewFolderType M 0:HasProperty Variable ControlMode ControlModeEnumeration 0:PropertyType M, RW 0:HasComponent Object Data 0:FolderType O 0:HasProperty Variable IdleEnergySavingMode 0:Boolean 0:PropertyType M, RW 0:HasComponent ... transitions and their conditions. Alarms The Alarms folder contains alarms of the machine module. Data The Data Folder contains additional data that is not identified elsewhere in this specification
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.5.1 OverviewClearProductionOrder See below. O 0:HasComponent Method CompleteProductionOrder See below. M 0:HasComponent Object Data 0:FolderType O 0:HasProperty Variable ProductionOrder ProductionOrderHeaderType 0:PropertyType M, RO 0:HasProperty Variable ... also invoked when AutoStart is True and AssignedProductionOrders [] contains more than one production order. Data The Data folder provides additional production data that is not identified elsewhere in this specification
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.17.1 OverviewFolderType M 0:HasProperty Variable ControlMode ControlModeEnumeration 0:PropertyType M, RW 0:HasComponent Object Data 0:FolderType O 0:HasComponent Method SendCommand See below. O 0:HasComponent Method SetControlMode ... equipment module. ControlMode The ControlMode describes the current control mode of the equipment module. Data The Data folder provides additional production data that is not already identified by TMC. State
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.22.1 OverviewFolderType M 0:HasProperty Variable ControlMode ControlModeEnumeration 0:PropertyType M, RW 0:HasComponent Object Data 0:FolderType O 0:HasComponent Object Interlocks 0:FolderType O 0:HasComponent Object Measurements ... control module. ControlMode The ControlMode describes the current control mode of the equipment module. Data The Data folder contains additional data whose structure and name are not known in advance
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.47.1 OverviewInformation Model , i.e. inheriting the Instance Declarations of that Node. 0:HasComponent Object Data 0:FolderType O 0:HasComponent Method EndSubCarrierLoading See below. M 0:HasComponent Method EndSubCarrierUnloading See below ... SubCarrierUnloadingEndedLogType 0:GeneratesEvent ObjectType SubCarrierUnloadingStartedLogType Conformance Units TMC Intralogistics at the machine BrowseName Description Data The Data folder organizes implementation specific data for the carrier. FormFactor The form factor
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model3.2.7 AlarmAlarm Acyclic Data about errors, maintenance status, application specific process alarms, incidents like pull/plug, updates and the like yielded by the Device
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelalso to extend the Information Model of a profile Device by adding vendor specific Data Objects . The standardized way to describe a PROFINET Device in machine-readable format ... information used for Device certification, and for the purpose of this specification elements describing Data Objects were added. This specification describes how OPC UA Servers can create an Information Model
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelClients . Typically, the use case consists of utilization of OPC UA standard mechanisms and data processing at the Client site. Table 15 - Use Cases and related Companion Specification contributions ... Case Description Companion Specification Contribution Data acquisition for forwarding to "Data Lake" to enable "Data Mining" Client applications gather the measurement data available for storage
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelalso. The Server reads the "RealIdentificationData" to obtain the IO Data available on the Device . The Server reads the "ARData" record to obtain a list ... InData". The Server learns the structure of each represented Submodule's IO Data by reading the corresponding "(Virtual)SubmoduleItem/IOData" elements in the GSDML file and creates
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.4 IO ChannelChannel Figure 11 shows the "IO Data" Sub-Aspect in the Functional Aspect of the Information Model. Figure 11 - IO Channel Organization The GsdGenIoDataType Objects relate ... associated GsdGenIoChannelType Objects using the 0:HasComponent ReferenceType . The "Data" components of the GsdGenIoChannelType Objects relate to the data item elements representing the channel data using 0:AssociatedWith
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.7 Data ObjectsData Objects Figure 18 shows the "Data Objects" sub-aspect in the Functional Aspect of the Information Model. Figure 18 - Data Objects Organization This aspect contains additional data ... present) represent Parameter records (see 6.6 ) and are not represented as Data Objects . Additional properties needed for Data Objects are described by "RefMeta" and "RecordMeta" child
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model6.9 Function GroupsGroups Determined by "Meta" elements with Property="opc:FunctionGroupName" describing Data Objects the Variables and Properties may be organized as components of 2:FunctionalGroupType folder Objects ... Object . Figure 24 shows the usage of 2:FunctionalGroupType Objects as folders organizing the Data Objects . Figure 24 - Usage of 2:FunctionalGroupType folder Objects The "FunctionGroupName" property
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelroot container for the Objects and Variables representing a Submodule's IO Data, Parameters , Data Objects and Alarms . Moreover, information regarding the communication status of the Submodule is provided. Table ... FunctionalGroupType OP 0:GeneratesEvent ObjectType GsdGenAlarmEventType Conformance Units PNGSDGM Device PNGSDGM Parameter PNGSDGM IO Data PNGSDGM Data Objects PNGSDGM BMP Access PNGSDGM Alarm Event The BrowseName of an instance shall
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag Methodcommunication status of the Submodule encoded as GsdGenIoCommunicationStatusEnumeration . If the Submodule is performing cyclic data transfer with a Controller , the Value shall be INDATA ( ConfigurationStatus Property is either ... provided. The Input Object contains the Objects and Variables representing the Submodules Input Data . See 6.3 and 6.4 for details. The Output Object contains the Objects and Variables representing
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelHasProperty Variable Number 0:UInt16 0:PropertyType M, RO 0:HasComponent Object Data GsdGenIoChannelDataType M, RO 0:HasComponent Object Quality GsdGenIoChannelQualityType O, RO Conformance Units PNGSDGM IO Data The Number ... Number" attribute of the GSDML "Channel" element. The Data Object represents the content of the "Data" child element of the GSDML "Channel" element
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model11.1 Conformance UnitsPROFINET Device structure (Module - Submodule - Channel ). Server PNGSDGM Parameter Server provides the Parameter data of the Devices in the Information Model . Server PNGSDGM IO Data Server provides the IO Data ... Devices in the Information Model . Server PNGSDGM Data Objects Server provides the vendor specific Data Objects yielded by vendor specific PROFINET data records. Server PNGSDGM BMP Access Server provides Data
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Modelrequired content of the RefMeta element and its Meta child elements describing a Data Object . Table 60 - RefMeta child elements <RefMeta Prefix="opc http://opcfoundation.org/PNGSDGM/ ... attribute of child element Mandatory/Optional <Meta> opc:Name Brief denomination of the Data Object , e.g. "Discharge Temperature", "Ambient Pressure" and the like
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelData Object attributes Table 64 and Table 65 define Data Object attributes together with their source. Table 64 - Data Object attributes obtained from GSDML Data Object attribute Source GSDML Name ... attribute ="opc:Name" GSDML Type DataType attribute of ParameterRecordDataItem/Ref element defining the Data Object, mapped according to B.1 . GSDML Range Value of "Content" attribute
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic ModelGSDML sample for Data Object specification The following GSDML snippet contains a sample "RecordDataList" defining Data Objects . <RecordDataList> <ParameterRecordDataItem ID="Readable_Record ... RECORD_NAME_Readable_Read_6000"/> <Const ByteOffset="0" Data="0x42 0x42 0x42 0x42 0x42 0x42"> </Const> <Ref ByteOffset
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.2.1.4 UploadProgramTemplateType should be set via an Upload method call based on the Data and AdditionalParameter inputs. Table 62 specifies its representation in the AddressSpace . Signature Upload ( [in] KeyValueType[] AdditionalParameters ... ByteString Data [out] String TemplateId ) Table 61 - Upload Method Arguments Argument Description AdditionalParameters Additional properties of the program template. Data Opaque program template data. TemplateId The unique identifier