OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.1 TrustListTypewill not actually update the TrustList until the CloseAndUpdate Method is called. Simply calling Close will discard the updates. The bit Masks in TrustListDataType structure allow the Client to only
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.2.5 CloseAndUpdateonly be called if the TrustList was opened for writing. If the Close Method is called any cached data is discarded and the TrustList is not changed. If only part
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Services7.8.5.2 CloseAndUpdateonly be called if the ConfigurationFile was opened for writing. If the Close Method is called any cached data is discarded and the configuration is not changed. The Client
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.1 PubSubConfigurationTypeactually update the PubSub configuration until the CloseAndUpdate Method is called. Simply calling Close will discard the updates. When a Client opens the file for reading and writing, the Client ... time the file is open to the currently required actions. The Client shall close the file as soon as it completes the sequence of actions needed to read or write
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.6 CloseAndUpdate Methodonly be called if the file was opened for writing. If the Close Method is called any cached data is discarded and the PubSub configuration is not changed. The file
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.2.3 CloseClose Close is used to close a file represented by a FileType. When a client closes a file, the handle becomes invalid. Signature Close( [in] UInt32 fileHandle ); Argument Description fileHandle ... description. Invalid file handle in call. Table 3 specifies the AddressSpace representation for the Close Method . Table 3 - Close Method AddressSpace definition Attribute Value BrowseName Close References NodeClass BrowseName DataType
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.4.3 GenerateFileForReadopened TransferFile . The fileHandle can be used to access the TransferFile Methods Read and Close . completionStateMachine If the creation of the file is completed asynchronous, the parameter returns the NodeId
-
OPC-10000-20 – OPC Unified Architecture - Part 20: File Transfer4.4.4 GenerateFileForWriteopened TransferFile . The fileHandle can be used to access the TransferFile Methods Write and Close . Method Result Codes (defined in Call Service) Result Code Description Bad_UserAccessDenied
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.3.3.1 CloseAndUpdate signatureonly be called if the File was opened for writing. If the Close Method is called, any cached data is discarded, and the ConnectionManager configuration is not changed. The file
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.7.2.1 OverviewTypeDefinition Other Subtype of the FiniteStateMachineType defined in OPC 10000-5 0:HasComponent Method Close O 0:HasComponent Object Closed StateType 0:HasComponent Object ClosedToError TransitionType 0:HasComponent Object ClosedToLocked ... HasComponent Object Unlocking StateType 0:HasComponent Object UnlockingToClosed TransitionType Conformance Units LADS CoverStateMachineType Close is a Optional Method that can be called in the Opened state to close the cover
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.7.2.2 CloseClose The Close Method can be called in the Opened state to close the cover of the Device . The signature of this Method is specified below. Table 122 specifies ... representation in the AddressSpace . Signature Close () Table 122 - Close Method AddressSpace Definition Attribute Value BrowseName Close References Node Class BrowseName DataType TypeDefinition ModellingRule
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.4.2.1 GenerateFileForReadopened TransferFile . The FileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.6.2.1 GenerateFileForReadopened TransferFile . The fileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.7.2.6 Recipe transfervision system. Thus, transfer can be carried out using the standard Open , Read , Write , Close methods of the FileType object
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management7.12.2.1 GenerateFileForReadopened TransferFile . The FileHandle can be used to access the TransferFile methods Read and Close . completionStateMachine If the creation of the file is completed asynchronously, the parameter returns the NodeId
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementB.1.7.2 Method-based recipe managementRead and Write methods to transfer the recipe content. The client uses the Close or CloseAndCommit methods of the temporary file object to end the data transfer and close
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementRead and Write methods of said component to transfer the data. It uses the Close method of said component to end the data transfer. Note that this does not imply
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)7.7.1 OverviewBoolean 0:PropertyType O,R 0:HasComponent Method Open O 0:HasComponent Method Close O 0:GeneratesEvent ObjectType MalfunctionAlarmType 0:GeneratesEvent ObjectType AirConnectionStatusChangedConditionType Conformance Units PAEFS AirConnectionType Basic PAEFS AirConnectionType ... ducting system or a valve. True in case of error. The Open and Close Methods can be called to open or close the connection. In a complex ducting system that