Search
43 result(s) for Address
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditionsthem. A Condition instance may be an Object that appears in the Server Address Space . If this is the case the ConditionId shall be the NodeId for the Object ... active Branches for a Condition instance. Branches are typically not visible in the Address Space and this document does not define a standard way to make them visible
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.1.2 Message sendingstep is delivery of the NetworkMessage to the Message Oriented Middleware through the configured Address
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.2.2 Message receptionrequired Message Oriented Middleware and establish a connection to it using the provided Address . Such a connection may simply be a multi-cast address when using
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.7.3 AddressAddress The Address parameter contains the network address information for the communication middleware. The different Structure DataTypes used to represent the Address are defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.3.4 AddressAddress The Address parameter contains the network address information for the communication middleware related to the WriterGroup . The different Structure DataTypes used to represent the Address are defined ... parameter shall be null if an address is not set at this level. If the parameter is set, it overwrites the Address on the PubSubConnection
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.6.1 AddressAddress The Address parameter contains the network address information for the communication middleware related to the DataSetReader . The different Structure DataTypes used to represent the Address are defined ... parameter shall be null if an address is not set at this level. If the parameter is set, it overwrites the Address on the PubSubConnection
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.6 PubSubConnectionConnection PubSubConnectionDataType The PubSubConnectionDataType Structure is defined in 6.2.7.5.1 . The ReaderGroup lists and the Address in PubSubConnectionDataType shall be empty. The configuration properties shall not be included in the PubSubConnectionDataType
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.2.1 Generalused to transport UADP NetworkMessages . A PubSubConnection for UDP shall have a unique Address across all PubSubConnections of an OPC UA Application . If the Address specifies a domain name then ... resolution to an IP address requires access to a domain name resolution service (e.g., the DNS protocol) that maps the domain name onto a usable network address
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.2.2 UDP multicast and broadcastmulticast and broadcast communication is configured on a PubSubConnection for Publisher and Subscriber . The Address parameter for a PubSubConnection is defined in 6.2.7.3 . The Url field in the Address ... used as destination address for NetworkMessages sent as UDP datagram. The Address is also used to receive UDP datagrams from the multicast IP address. All DataSetWriters and DataSetReaders that send
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.2.3 UDP unicastunicast For UDP unicast, the address information for the Subscriber is configured on the PubSubConnection and the address information for the Publisher is configured on the WriterGroup . The receive port ... unicast communication is configured on a PubSubConnection . The Address parameter for a PubSubConnection is defined in 6.2.7.3 . All NetworkMessages for one port are received through one PubSubConnection. The filtering
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.2.4.1 GeneralPublisher as DTLS Client Addressing for DTLS is similar to UADP unicast. The receive address for DTLS unicast communication is configured on a PubSubConnection . The Address parameter for a PubSubConnection ... defined in 6.2.7.3 . The syntax of the URL used in the PubSubConnection Address parameter has the following form: opc.dtls://localhost:<port> The send address is configured
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.3 OPC UA Ethernetheaders. The syntax of the Ethernet transporting protocol URL used in the Address parameter defined in 6.2.7.3 has the following form: opc.eth://<host ... host is a MAC address, an IP address or a registered name like a hostname. The format of a MAC address is six groups of hexadecimal digits, separated by hyphens
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.2 AddressAddress The syntax of the MQTT transporting protocol URL used in the Address parameter defined in 6.2.7.3 has the following form: mqtts://<domain name>[:<port
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.2 PubSubConfigurationRefMaskfollowing structure fields are used for the match, the others are ignored. TransportProfileUri Address TransportSettings For the WriterGroupDataType , the following structure fields are used for the match, the others
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.5.2 PubSubConnectionTypeHasComponent Variable TransportProfileUri String SelectionListType Mandatory HasProperty Variable ConnectionProperties KeyValuePair[] PropertyType Mandatory HasComponent Object Address NetworkAddressType Mandatory HasComponent Object TransportSettings ConnectionTransportType Optional HasWriterGroup Object <WriterGroupName> WriterGroupType OptionalPlaceholder HasReaderGroup ... defined in 6.2.7.2 . The Property is initialized with the default transport protocol for the Address during the creation of the connection. The SelectionValues Property of the SelectionListType shall contain
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.3.1.2 DatagramWriterGroupTransportTypeHasProperty Variable MessageRepeatCount Byte PropertyType Optional HasProperty Variable MessageRepeatDelay Duration PropertyType Optional HasComponent Object Address NetworkAddressType Optional HasProperty Variable QosCategory String PropertyType Optional HasProperty Variable DatagramQos TransmitQosDataType[] PropertyType Optional HasProperty ... Datagram The MessageRepeatCount is defined in 6.4.1.3.1 . The MessageRepeatDelay is defined in 6.4.1.3.2 . The Address is defined in 6.4.1.3.4 . The abstract NetworkAddressType is defined in 9.1.5.3 . The default type used
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubReferences NodeClass BrowseName DataType TypeDefinition ModellingRule Subtype of DataSetReaderTransportType defined in 9.1.8.3 . HasComponent Object Address NetworkAddressType Optional HasProperty Variable QosCategory String PropertyType Optional HasProperty Variable DatagramQos ReceiveQosDataType[] PropertyType Optional HasProperty ... Variable Topic String PropertyType Optional Conformance Units PubSub Model Datagram The Address is defined in 6.4.1.6.1 . The abstract NetworkAddressType is defined in 9.1.5.3 . The default type used for concrete instances
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubB.2.3 AddressB.2.3 Address The syntax of the Kafka transporting protocol URL used in the Address parameter defined in 6.2.7.3 has the following form: kafka://<domain name>[:<port
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubB.3.2 AddressB.3.2 Address The syntax of the AMQP transporting protocol URL used in the Address parameter defined in 6.2.7.3 has the following form: amqps://<domain name>[:<port
-
OPC-10000-17 – OPC Unified Architecture - Part 17: Alias NamesSecurityGroup within an SKS. The SecurityKeyServices that is associated with the published messages. The Address that is associated with the published messages. It defines a multi-cast address to which
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network Model5.3.2.3 LldpManagementAddressTypeLldpManagementAddressType This Structure DataType is used to represent the YANG list management-address as defined in IEEE 802.1ABcu-2021 . The LldpManagementAddressType is formally defined in Table 44 . Table ... LldpManagementAddressType structure Name Type Description LldpManagementAddressType Structure AddressSubtype UInt32 Type of address (8.5.9.3 of IEEE Std 802.1AB-2016 ), enumeration based on ianaAddressFamilyNumbers IETF RFC 3232 ) Address String Management address
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelClass BrowseName DataType TypeDefinition Other Subtype of the 4:CommunicationFlowConfigurationType 0:HasComponent Variable 4:Address 0:NetworkAddressDataType 0:SelectionListType O 0:HasComponent Variable 4:TransportProfileUri 0:String 0:SelectionListType ... PublishingInterval 0:HasProperty Variable 4:AvailableRanges 2:IntervalRange[] 0:PropertyType O The optional Address specifies the destination network address to be used for transmission of NetworkMessages by the Publisher
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubtype of the 0:BaseObjectType defined in OPC 10000-5 0:HasComponent Variable 4:Address 0:NetworkAddressDataType 0:SelectionListType O 0:HasComponent Variable 4:MessageReceiveTimeout 0:Duration 0:SelectionListType ... Variable 4:ReceiveQos 0:ReceiveQosDataType[] 0:SelectionListType O ConformanceUnits UAFX ConnectionManager PubSubCommunicationFlowConfiguration The optional Address specifies the network address to be used for the reception of NetworkMessages at the Subscriber
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelPubSubConnections, specific handling applies: OPC 10000-14 requires a PubSubConnection to have a unique Address across all PubSubConnections . This implies that there is exactly one PubSubConnection with a specific Address ... determining the PublisherId to be used for that Address . It is therefore recommended that the entity generating the ConnectionConfigurationSet sets the names and PublisherIds of PubSubConnections to null and that
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubtype of the 0:BaseDataVariableType defined in OPC 10000-5 0:HasComponent Variable 4:Address 0:UriString 0:SelectionListType M 0:HasComponent Variable 4:SecurityMode 0:MessageSecurityMode 0:SelectionListType ... HasComponent Variable 4:ServerUri 0:UriString 0:SelectionListType M ConformanceUnits UAFX ConnectionManager Base Address is specified as a DiscoveryUrl in the form scheme://hostname[:port][/path] as defined
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubtype of the 0:BaseDataVariableType defined in OPC 10000-5 0:HasComponent Variable 4:Address 0:UriString 0:SelectionListType M 0:HasComponent Variable 4:SecurityPolicyUri 0:String 0:SelectionListType ... HasComponent Variable 4:UsePushModel 0:Boolean 0:BaseDataVariableType M ConformanceUnits UAFX ConnectionManager Base Address specifies the address of the SKS as a DiscoveryUrl in the form: scheme://hostname[:port][/path
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model10.42 RelatedEndpointDataTypestructure Name Type Description RelatedEndpointDataType Structure Subtype of Structure defined in OPC 10000-5 Address 0:UriString Specifies the Server's address as DiscoveryUrl in the form "scheme://hostname ... RelatedEndpointDataType is set to null by setting ConnectionEndpoint to null or empty and the Address to null. The RelatedEndpointDataType representation in the AddressSpace is formally defined in Table 211 . Table
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model10.46 ServerAddressDataTypestructure Name Type Description ServerAddressDataType Structure Subtype of Structure defined in OPC 10000-5 Address 0:UriString Specifies the server's address as DiscoveryUrl in the form "scheme://hostname ... SecurityMode is the MessageSecurityMode to be used for establishing a secure communication to the Address . SecurityPolicyUri 0:String SecurityPolicyUri is a string that contains the security policy to use when
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model13.2.1 Locating Server via GDSLocating Server via GDS If a GDS address ( GlobalDiscoveryServers ) is defined (see 6.7.2 ), the GDS is queried to find the Server . If an array of GDS addresses is provided each ... QueryApplications , GetEndpoints , OpenSecureChannel , CreateSession and ActivateSession on the Server Address with the specified SecurityMode (see 9.2.2 for the description of the provided Server information). Figure 64 - Client connection process
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model13.2.2 Connecting to Server via LDSusing FindServers , GetEndpoints , OpenSecureChannel , CreateSession and ActivateSession) on the Server Address with the specified SecurityMode (see 9.2.2 for the description of the provided Server information). Figure 65 - Client connection process
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.1 Overviewconfiguration contains various settings that have an influence on the communication model, including Address , PublishingInterval , QoS , MessageReceiveTimeout, ReceiveQos and SecurityMode (see 6.13.3 for additional details). Some of these settings ... complex to apply, such as the Address . Depending on the type of connection, this Address might contain a destination address, a receiving address, or a multicast address
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.6 Autonomous subscriberwhich applies only to the Publisher of the information flow can be omitted, i.e., Address and TransmitQos (see E.4.1 ). Figure E.15 - Autonomous subscriber illustration
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeldetails. Depending on the transport profile and on the type of Address (unicast or multicast), the Address will be in the PubSubConnection or in the WriterGroup's TransportSettings ... example, if UDP-UADP is used as the transport profile, a unicast address is set in the WriterGroup, but a multicast address is set in the PubSubConnection . TransportProfileUri is used
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelupdate PublisherId after issuing the ReserveCommunicationIdsCmd ; see E.2 for details. For a Subscriber, the Address will be in the PubSubConnection . See 6.13.3.3 on how to set the Address . TransportProfileUri
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelnull. The DataSetReader element TransportSettings is transport-specific. For UDP-UADP, the Address is set to null. QosCategory and DatagramQos are derived from ReceiveQos and Qos ; see 6.13.3.3 for details
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelCommunicationFlowConfigurationConfDataType properties Key DataType Description 4:PubSubConnectionAddress NetworkAddressDataType Allows the configuration of the PubSubConnection Address for Publishers of a unidirectional connection without heartbeat or other cases where the Address configuration ... flow does not include the information needed to set the Address in the PubSubConnection . One example is a unidirectional connection without heartbeat using UDP unicast. The CommunicationFlowConfigurationConfDataType representation
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelPubSubCommunicationFlowConfigurationConfDataType structure Name Type Description Optional PubSubCommunicationFlowConfigurationConfDataType Structure Subtype of CommunicationFlowConfigurationConfDataType defined in F.1.4 Address 4:AddressSelectionDataType Address specifies the destination network address to be used for transmission of NetworkMessages ... mapping to be used. If TransportProfileUri is omitted, the default transport protocol for the Address shall be used. True TransportProfileUriSelection 0:String[] Selection list options for TransportProfileUri. True TransportProfileUriModify
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelStructure defined in OPC 10000-5 BrowseName 0:String BrowseName of the flow. False Address 4:AddressSelectionDataType Address specifies the network address to be used for the reception of NetworkMessages
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelName Type Description Optional SecurityKeyServerAddressConfDataType Structure Subtype of Structure defined in OPC 10000-5 Address 0:UriString Address is specified as a DiscoveryUrl of the server to connect ... connection establishment. False AddressSelection 0:UriString[] Selection list options for Address . True AddressModify 0:Boolean Flag indicating if the Address options can be modified. True SecurityPolicyUri 0:String SecurityPolicyUri
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelF.1.11 ServerAddressConfDataTypeF.1.11 ServerAddressConfDataType This Structure DataType holds the information for the Server address. It is semantically equivalent to the ServerAddressType as defined in 9.2.2 , except that the field Namespaces is added ... Structure defined in OPC 10000-5 BrowseName 0:String BrowseName of the Server address. False Address 0:UriString Address is specified as a DiscoveryUrl of the server to connect
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networking5.6.4.2 Application and QoS engineeringaddresses for each Connection between the Controllers by setting the sender and receiver Address, QosCategory, and PriorityLabel Variables in the ConnectionManager PubSubCommunicationFlowConfiguration . Figure 8 illustrates the Variables used by Controller ... used by a Connection as part of the PubSubCommunicationFlowConfiguration sender and receiver Address parameters. A NetworkInterface Variable may either be the BrowseName of a physical interface or a VLAN interface
-
OPC-10000-82 – OPC Unified Architecture - Part 82: UAFX Networkingsetting up the PubSubConfiguration in Controller A and Controller B, focusing on QoS and Address as contained in the PubSubCommunicationFlowConfiguration. To this end, the ConnectionManager invokes the EstablishConnections Method ... FunctionalEntities being connected, as depicted in Figure 12 label A. For details on Address and QoS, see OPC 10000‑14 . a As no OPC UA Information Model mechanism exists today
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.6 UAFX ConnectionManagerPubSubCommunicationFlowConfiguration Is capable of supporting an instance of the PubSubCommunicationFlowConfigurationType. Server UAFX ConnectionManager PubSubCommunicationFlowConfiguration Address Is capable of supporting an instance of the PubSubCommunicationFlowConfigurationType , including the Address Variable . Server UAFX ... SubscriberConfiguration Is capable of supporting an instance of the SubscriberConfigurationType . Server UAFX ConnectionManager SubscriberConfiguration Address Is capable of supporting an instance of the SubscriberConfigurationType , including the Address Variable . Server UAFX