Search
25 result(s) for methodId
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.2 ParametersHasComponent Reference (or subtype of HasComponent Reference ) to the Method specified in methodId . In case of an ObjectType , the ObjectType shall be the source of a HasComponent Reference (or subtype ... HasComponent Reference ) to the Method specified in methodId. In this case the Method shall not have a ModellingRule . See OPC 10000-3 for a description of Objects and their Methods
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.27 AuditUpdateMethodEventTypedefined in 6.4.3 , which means it inherits the InstanceDeclarations of that Node. HasProperty Variable MethodId NodeId PropertyType Mandatory HasProperty Variable StatusCodeId StatusCode PropertyType Optional HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory ... reflect changes to the address space or updated values triggered by the method. MethodId identifies the method that was called. StatusCodeId identifies the StatusCode of the Method executed
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Modelinherits the InstanceDeclarations of that Node. HasProperty Variable ObjectId ExpandedNodeId PropertyType Mandatory HasProperty Variable MethodId ExpandedNodeId PropertyType Mandatory HasProperty Variable StatusCodeId StatusCode PropertyType Mandatory HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory ... namespaceUri , the serverIndex shall be set to 0 and the serverIndex shall be ignored. MethodId identifies the method that was called. The ExpandedNodeId shall use a namespaceUri , the serverIndex shall
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.4 Disable MethodNode . Since Condition instances are not required to be defined in the AddressSpace , the MethodId that is passed in the Call Service shall be the NodeId of the Disable Method
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.5 Enable MethodCondition. Since Condition instances are not required to be defined in the AddressSpace , the MethodId that is passed in the Call Service shall be the NodeId of the Enable Method
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.6 AddComment MethodCall Service) Table 16 - AddComment result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.7 ConditionRefresh MethodConditionType . To invoke this Method , the call shall pass the well-known MethodId of the Method on the ConditionType and the ObjectId shall be the well-known NodeId
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.5.8 ConditionRefresh2 MethodConditionType . To invoke this Method , the call shall pass the well-known MethodId of the Method on the ConditionType and the ObjectId shall be the well-known NodeId
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.7.3 Acknowledge MethodConditionBranchAlreadyAcked See Table 137 for the description of this result code. Bad_MethodInvalid The MethodId is not the well-known method of the AcknowledgeableConditionType or MethodId does not refer
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.5 Reset MethodCall service) Table 44 - Reset result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.6 Reset2 MethodCall service) Table 47 - Reset2 result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.7 Silence MethodCall service) Table 49 - Silence result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.8 Suppress MethodCall Service) Table 51 - Suppress result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.9 Suppress2 MethodCall Service) Table 54 - Suppress result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.10 Unsuppress MethodCall Service). Table 56 - Unsuppress result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.11 Unsuppress2 MethodCall Service). Table 59 - Unsuppress result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.12 RemoveFromService MethodCall Service ). Table 61 - RemoveFromService result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.13 RemoveFromService2 MethodCall Service ) Table 64 - RemoveFromService2 result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.14 PlaceInService MethodCall Service ). Table 66 - PlaceInService result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.15 PlaceInService2 MethodCall Service ) Table 69 - PlaceInService2 result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.16 GetGroupMemberships MethodCall Service ) Table 71 - GetGroupMemberships result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.2 Unshelve MethodUnshelve Method sets the instance of AlarmConditionType to the Unshelved state. Normally, the MethodId found in the Shelving child of the Condition instance and the NodeId of the Shelving object
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.4 TimedShelve Methoddefined in Table 81 and result codes are described in Table 82 ). Normally, the MethodId found in the Shelving child of the Condition instance and the NodeId of the Shelving
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.17.6 OneShotShelve MethodOneShotShelve Method sets the instance of AlarmConditionType to the OneShotShelved state. Normally, the MethodId found in the Shelving child of the Condition instance and the NodeId of the Shelving object
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions9.4 Reset MethodCall Service) Table 147 - Suppress result codes Result Code Description Bad_MethodInvalid The MethodId provided does not correspond to the ObjectId provided. See 10000-4 for the general description