OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.6.1 WriterGroupIdDataType UInt16 is an identifier for the WriterGroup and shall be unique across all WriterGroups for a PublisherId. All values, except for 0, are valid. The value 0 is defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.6.4 PriorityPriority with DataType Byte defines the relative priority of the WriterGroup to all other WriterGroups across all PubSubConnections of the Publisher . If more than one WriterGroup needs to be processed
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.6.7.1 WriterGroupDataTypeWriterGroupDataType This Structure DataType is used to represent the configuration parameters for WriterGroups . It is a subtype of PubSubGroupDataType defined in 6.2.5.7 . The WriterGroupDataType is formally defined in Table
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.7.5.1 PubSubConnectionDataTypeconcrete subtype is defined for the transport mapping, the field shall be null. True WriterGroups WriterGroupDataType[] The WriterGroups contained in the PubSubConnection . The WriterGroup is defined in 6.2.6 . ReaderGroups ReaderGroupDataType
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.12.1 PubSubConfigurationDataTypePubSubConnections contained in the configuration. The PubSubConnectionDataType is defined in 6.2.7 . The connection includes WriterGroups and ReaderGroups . Enabled Boolean The enabled state of the PubSub configuration. This Enable state corresponds
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubThis Structure DataType is used to represent the datagram specific transport mapping parameters for WriterGroups . It is a subtype of the WriterGroupTransportDataType defined in 6.2.6.7.2 . The DatagramWriterGroupTransportDataType is formally defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubThis Structure DataType is used to represent the datagram specific transport mapping parameters for WriterGroups . It is a subtype of the DatagramWriterGroupTransportDataType defined in 6.4.1.3.3 . The DatagramWriterGroupTransportDataType is formally defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubThis Structure DataType is used to represent the broker-specific transport mapping parameters for WriterGroups . It is a subtype of the WriterGroupTransportDataType defined in 6.2.6.7.2 . The BrokerWriterGroupTransportDataType is formally defined
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.2 MessageTypesPubSubConnection . PubSubConnection Discovery message with the PubSubConnection configured in the Publisher including WriterGroups and DataSetWriters for data and events. ActionRequest Action execution request message sent by the Requestor ... message with the Responder related PubSubConnection information for Actions configured in the Publisher including WriterGroups and DataSetWriters for Actions. Each message mapping defines the structure of each supported MessageType
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.4.2 NetworkMessage layoutUnique id for the WriterGroup in the Publisher. A Subscriber can skip NetworkMessages from WriterGroups it does not expect NetworkMessages from. This field shall be omitted
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.6.8 PubSubConnectionIncludeWriterGroups is true in the PubSubConnection information probe message. The DataSetWriter lists in the WriterGroups shall be contained, if the IncludeDataSetWriters is true in the PubSubConnection information probe message
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubPubSubConnectionDataType is defined in 6.2.7.5.1 . Only DataSetWriters used for Actions are included. All WriterGroups and DataSetWriters not used for Actions shall be excluded. The ReaderGroup lists in PubSubConnectionDataType shall ... IncludeWriterGroups is true in the PubSubConnection information probe message. The DataSetWriter lists in the WriterGroups shall be contained, if the IncludeDataSetWriters is true in the PubSubConnection information probe message
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.4.6.12.4 Publisher information probe messagenull or empty, all PubSubConnections are returned. IncludeWriterGroups Boolean Flag indicating if the WriterGroups should be contained in the PubSubConnection configuration announcement message. IncludeDataSetWriters Boolean Flag indicating if the DataSetWriters
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.2.5.5.8 ActionResponderPubSubConnectionDataType Structure is defined in 6.2.7.5.1 . Only DataSetWriters used for Actions are included. All WriterGroups and DataSetWriters not used for Actions shall be excluded. The ReaderGroup lists in PubSubConnectionDataType shall
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.6 Transport Limits and Keep Alivealive message was not sent by any writer in the specified time. If multiple WriterGroups are configured, the group with the highest KeepAliveTime setting is used for the calculation
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.7.3 data Topic levelPrefix>, <Encoding> and <PublisherId>. The PubSubConnection specifies the WriterGroups and DataSetWriters for a Publisher
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.7.4 metadata Topic levelPrefix>, <Encoding> and <PublisherId>. The PubSubConnection specifies the WriterGroups and DataSetWriters for a Publisher
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.7.9 action-request Topic levelPrefix>, <Encoding> and <Responder>. The PubSubConnection specifies the WriterGroups and DataSetWriters for a Responder
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.7.10 action-response Topic levelPrefix>, <Encoding> and <Responder>. The PubSubConnection specifies the WriterGroups and DataSetWriters for a Responder
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub7.3.4.7.12 action-metadata Topic levelPrefix>, <Encoding> and <PublisherId>. The PubSubConnection specifies the WriterGroups and DataSetWriters for a Publisher
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.3 PubSubConfigurationRefDataTypeReferenceWriterGroup and/or ReferenceWriter bits are true, it specifies the index within the WriterGroups array of the related connection. If ReferenceWriterGroup is true, the add, modify or delete bit is applied
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.3.7.5 ReserveIds Methodmapping profile scope for the ID request. NumReqWriterGroupIds The number of requested Ids for WriterGroups . NumReqDataSetWriterIds The number of requested Ids for DataSetWriters. DefaultPublisherId The default PublisherId of the Server ... requested TransportProfileUri . WriterGroupIds The reserved Ids for WriterGroups for the requested TransportProfileUri . DataSetWriterIds The reserved Ids for DataSetWriters for the requested TransportProfileUri Method Result Codes ResultCode Description Bad_UserAccessDenied
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.7 WriterGroupTransportTypeabstract base type for Objects representing transport protocol mapping specific settings for WriterGroups . The WriterGroupTransportType is formally defined in Table 280 . Table 280 - WriterGroupTransportType definition Attribute Value BrowseName WriterGroupTransportType IsAbstract
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.8 WriterGroupMessageTypeObjectType is the abstract base type for Objects representing message mapping specific settings for WriterGroups . The WriterGroupMessageType is formally defined in Table 281 . Table 281 - WriterGroupMessageType definition Attribute Value BrowseName
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.12.1 PubSubCapabilitiesTypelimit on the number of connections. The MaxWriterGroups Variable defines the maximum number of WriterGroups that can be configured for the OPC UA Application . A value of 0 indicates that ... Application forces no limit on the number of WriterGroups . The MaxReaderGroups Variable defines the maximum number of ReaderGroups that can be configured for the OPC UA Application . A value
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubA.2.1.2 Overviewthis purpose. PublisherId and WriterGroupId identify the WriterGroup . The NetworkMessageNumber is important for WriterGroups which distribute their DataSet s over more than one NetworkMessage , and the GroupVersion allows the Subscriber
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSubB.2.1 GeneralKafka topics and receive OPC UA NetworkMessages . Kafka topics are configured throgh QueueNames in WriterGroups , DataSetWriters and DataSetReaders . A Broker may persist messages so they can be delivered even
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.4.2 PubSubused. The EstablishConnections implementation shall reserve the requested number of IDs for both WriterGroups and DataSetWriters for each requested TransportProfileUri . For additional details, see OPC 10000-14 ReserveIds Method, including
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelAutomationComponents with the returned PublisherIds as required. It is recommended to use ElementAdd for WriterGroups and ReaderGroups under the assumption that each ConnectionManager maintains groups separate from other ConnectionManagers . After
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeldetails NumReqWriterGroupIds 0:UInt16 Indicates the number of requested node ids for WriterGroups . NumReqDataSetWriterIds 0:UInt16 Indicates the number of requested node ids for DataSetWriter . The PubSubReserveCommunicationIdsDataType representation
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeladdressed Server for the requested TransportProfileUri . WriterGroupIds 0:UInt16[] Indicates the reserved IDs for WriterGroups for the requested TransportProfileUri . DataSetWriterIds 0:UInt16[] Indicates the reserved IDs for DataSetWriters
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelusing the ReserveCommunicationIdsCmd to reserve WriterGroupIds and DataSetWriterIds for the publishing side (i.e., WriterGroups and DataSetWriters for AC1) and to retrieve the default PublisherId . This Call will typically contain
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelusing the ReserveCommunicationIdsCmd to reserve WriterGroupIds and DataSetWriterId s for the publishing side (i.e., WriterGroups and DataSetWriters for AC1, AC2 and AC3) and to retrieve the default PublisherId . The ConnectionManager ... using the ReserveCommunicationIdsCmd to reserve WriterGroupIds and DataSetWriterId s for the publishing side (i.e., WriterGroups and DataSetWriters for AC1) and to retrieve the default PublisherId . The ConnectionManager updates the communication
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelcalls SetSecurityKeys on the AutomationComponent with a specific SecurityGroupId , all WriterGroups and DataSetReaders utilising the SecurityGroupId on the AutomationComponent will get the new set of keys. PubSubKeyPushTargets are used
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.6.1 OverviewSubscriberConfiguration child Objects and SecurityKeyServerAddress Object, contain Variables related to PubSubConnections, ReaderGroups and WriterGroups in the PubSubConfiguration. All of the related Variables are of SelectionListType , which allows limiting the choice