Search
12 result(s) for WarningCodes
-
OPC-30020 – MDIS OPC UA Companion Specificationsubtypes of this ObjectType defined in this specification shall define a set standard WarningCodes that apply to that ObjectType (bits 0-15). In addition, the SPCS vendor may provide vendor
-
OPC-30020 – MDIS OPC UA Companion Specificationusable value, there is an I/O fault. The MDISDiscreteInstrumentObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 9 . All subtypes of this the MDISDiscreteInstrumentObjectType ... will inherits all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 9 - MDISDiscreteInstrumentObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion SpecificationTable 14 - MDISDiscreteArbitrationObjectType FaultCode Values Value Bit no. Description The MDISDiscreteArbitrationObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 15 (currently empty, no additional ... warning codes defined). All subtypes of this the MDISDiscreteArbitrationObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 15 - MDISDiscreteArbitrationObjectType WarningCode
-
OPC-30020 – MDIS OPC UA Companion Specificationusable value, there is an I/O fault. The MDISDigitalInstrumentObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 9 . All subtypes of this the MDISDigitalInstrumentObjectType ... will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 21 - MDISDigitalInstrumentObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion SpecificationTable 26 - MDISDigitalArbitrationObjectType FaultCode Values Value Bit no. Description The MDISDigitalArbitrationObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 27 (currently empty, no additional ... warning codes defined). All subtypes of this the MDISDigitalArbitrationObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 27 - MDISDigitalArbitrationObjectType WarningCode
-
OPC-30020 – MDIS OPC UA Companion SpecificationTable 36 - MDISInstrumentArbitrationObjectType FaultCode Values Value Bit no. Description The MDISInstrumentArbitrationObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 37 (currently empty, no additional ... warning codes defined). All subtypes of this the MDISInstrumentArbitrationObjectType will inherits all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 37 - MDISInstrumentArbitrationObjectType WarningCode
-
OPC-30020 – MDIS OPC UA Companion Specificationcommand. CommunicationFault 1 Not possible to operate the choke. The MDISChokeObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 )in Table 40 . All subtypes of this ... MDISChokeObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 40 - MDISChokeObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion Specificationcommand. CommunicationFault 1 Not possible to operate the choke. The MDISElectricChokeObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 50 . All subtypes of this ... MDISElectricChokeObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 50 - MDISElectricChokeObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion Specificationverification failed FlowFeedbackFailure 5 Flow check feedback verification failed The MDISValveObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 53 . All subtypes of this ... MDISValveObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 53 - MDISValveObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion Specificationcommand. CommunicationFault 1 Not possible to operate the valve. The MDISCIMVObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 59 . All subtypes of this ... MDISCIMVObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 59 - MDISCIMVObjectType WarningCode Values Value Bit no. Description SideAProblem 0 There
-
OPC-30020 – MDIS OPC UA Companion SpecificationTable 75 - MDISMotorObjectType FaultCode Values Value Bit no. Description The MDISMotorObjectType defines the standard WarningCodes (for bits 0-15 as defined in 6.2.2 ) in Table 76 (currently empty, no additional ... warning codes defined). All subtypes of this the MDISMotorObjectType will inherit all WarningCodes defined in this table. Subtypes may define additional WarningCodes in their own table. Table 76 - MDISMotorObjectType WarningCode
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerFaultCodes Server MDIS Base Warning Support the Warning flag Server MDIS Base WarningCode Support WarningCodes Server MDIS Base Enabled Support the Enabled flag and the EnableDisable Method to toggle