Search
18 result(s) for True
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model7.18 SelectionListTypeSelections Property by setting the optional RestrictToList Property to a value of True . If the RestrictToList Property is not present or has a value of False then the value
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model7.27 FrameTypeformally defined in Table 97 . Table 97 - FrameType Definition Attribute Value BrowseName FrameType IsAbstract True ValueRank Scalar DataType Frame References NodeClass BrowseName DataType TypeDefinition Modelling Rule Subtype of the BaseDataVariableType ... does not define the fields itself, but subtypes shall create those fields. Constant is True when the Value of the frame never changes. If the Value may change
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.4.1.7.5 VerifyClientCertificateDTLS handshake. If this parameter is not set then it defaults to True
-
OPC-10000-18 – OPC Unified Architecture - Part 18: Role-Based Security4.4.1 RoleType definitionempty array. If this Property is an empty array and CustomConfiguration is not TRUE , then the Role cannot be granted to any Session . The Role shall only be granted ... Session if all of the following conditions are true: The UserIdentityToken complies with Identities. The Applications Property is not configured or the Client Certificate complies with the Applications settings
-
OPC-10000-22 – OPC Unified Architecture - Part 22: Base Network Model5.3.3.1 LldpSystemCapabilitiesMapspecified in the OptionSet . All other variables shall only be set to True , if they are applicable for this device. Its representation in the AddressSpace is defined in Table
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelD.3.6.2 Using preconfigured DataSetsdata exchange (indicated in PublisherCapabilities as one of the PreconfiguredPublishedDataSets ). PreconfiguredDataSetOnly set to True indicates that the data contained in this folder can only be exchanged using the preconfigured PublishedDataSet
-
OPC-10101 – OPC UA for WoT Binding6.4.1 UA Variable readablecorresponding readOnly term of the DataSchema class in the TD should be set to true . Since a readable UA Variable can be also subscribed by a Client, the term ... observable term of the PropertyAffordance class in the TD should be set to true
-
OPC-10101 – OPC UA for WoT Binding6.4.2 UA Variable writeablecorresponding writeOnly term of the DataSchema class in the TD should be set to true
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.1 Generalscanned data. Option 4: The reader starts the scanning when the Client writes True to the Variable ScanActive . The scan result is provided through the Variable LastScanData . The configuration
-
OPC-30010 – OPC UA for AutoId Devices - AutoID: OPC UA for AutoId Devices6.1.3.8 Variable ScanActiveClients that are limited to Data Access functionality. The scan is triggered by writing True to the Variable Value . The behaviour of the scan is defined by the parameters
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices15.2 ActualValueActiveActualValueActive Indicates the current status of the controller. ActualValueActive is true , if the controller is switched on via SetValueActive and EnablePower (see 9.7 ) is true
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems11.3 AdditiveActivatedAdditiveActivated Is true if the additive is activated
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systemsthis case the ActualValues of AdditiveFraction and AdditiveVolume are equal to the SetValues. Is true if the closed loop control of the additive is activated. In this case, the ActualValues
-
OPC-40210 – OPC UA for Geometric Measurement Systems8.14 RotaryTableTypeConformance Units GMS RotaryTableType Identification is performed according to MachineryIdentificationType . IsIntegrated is defined as True if the RotaryTable is integrated into the GMS and cannot be removed. NumberOfAxes defines
-
OPC-40210 – OPC UA for Geometric Measurement SystemsConformance Units GMS SensorExchangeRackType Identification is performed according to MachineryIdentificationType . IsAvailable is defined as True if the SensorExchangeRack is available into
-
OPC-40210 – OPC UA for Geometric Measurement Systems8.16 TipExchangeRackTypeConformance Units GMS SensorExchangeRackType Identification is performed according to MachineryIdentificationType . IsAvailable is defined as True if the TipExchangeRack is available into
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsSTCompRamType Additional References SourceBrowsePath Reference Type Is Forward TargetBrowsePath 4:MachineryBuildingBlocks LifetimeCounters 0:HasComponent True 4:Monitoring 4:Process RemainingCycles 4:MachineryBuildingBlocks LifetimeCounters 0:HasComponent True 4:Monitoring 4:Process ... AnalogUnitType O DrumPresent indicates if a drum is present on the ram unit. True is representing the state "present" while False represents "not present". DiscreteFillingLevel gives
-
OPC-40702 – OPC UA for Surface Technology - Organic Coating Technology - Material Supply SystemsBoolean 0:TwoStateDiscreteType O VesselVibration represents the state (on/off) of the powder vibration unit. True is representing the state "VibrationOn" while False represents "VibrationOff