Search
24 result(s) for SerialNumber
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS3.2.7 Serial NumberSerial Number A string of characters with a defined syntax used for purposes of establishing uniqueness between otherwise identical objects. Serial numbers may be numeric, alphanumeric and contain symbols
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.2 FxAssetType definitionHasProperty Variable 5:DeviceClass 0:String 0:PropertyType O 0:HasProperty Variable 5:SerialNumber 0:String 0:PropertyType O 0:HasProperty Variable 5:ProductInstanceUri 0:String 0:PropertyType ... this Property is provided, the string should be from some standardised dictionary. " SerialNumber is a unique production number of the manufacturer of the Asset . This is often stamped
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.3.3 VerifyAsset methodoptional Variables in its Information Model . If at least one of the optional Variables, SerialNumber and/or ProductInstanceUri, is provided, then the VerificationModes AssetIdentity and AssetIdentityAndCompatibility shall be supported . The signature ... SoftwareRevision (O) AssetIdentity: IVendorNameplateType ManufacturerUri (M), IVendorNameplateType ProductCode (M), At least one of: IVendorNameplateType SerialNumber , IVendorNameplateType ProductInstanceUri AssetIdentityAndCompatibility : All mandatory Variables of both AssetCompatibility and AssetIdentity are mandatory
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelD.2.4 Verifying AssetsCPU1: ProductCode "ZY456", MajorAssetVersion "2", MinorAssetVersion"4" , and SerialNumber "N475655", and for CPU2: ProductCode "YY544", MajorAssetVersion "2", MinorAssetVersion ... SerialNumber "Z234545". A Client checking for compatibility of the Assets Controller1 and Controller2 by using VerificationMode AssetCompatibility will set the ExpectedVerificationVariables in VerifyAsset to the values as stated
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.4 UAFX FxAssetIAssetRevisionType Interface including the VerificationMode of AssetIdentityAndCompatibility. Server UAFX IVendorNameplate SerialNumberOrProductInstanceUri Supports either the SerialNumber or ProductInstanceUri Property of the IVendorNameplate Interface. IAssetExtensions Server UAFX IAssetExtensions Connectors Supports the Connectors
-
OPC-10000-100 – OPC Unified Architecture - Part 100: DevicesDeviceClass 0:String 0:PropertyType O Product instance-specific Properties 0:HasProperty Variable 1:SerialNumber 0:String 0:PropertyType O 0:HasProperty Variable 1:ProductInstanceUri 0:String 0:PropertyType ... utilize this Interface (device models) will likely introduce such classifications. Product instance specific Properties : SerialNumber is a unique production number provided by the manufacturer. This is often stamped
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.7.5 Solution packagesManufacturerUri 0:String ManufacturerUri (see 4.5.3 ). True ProductCode 0:String ProductCode (see 4.5.3 ). True SerialNumber 0:String SerialNumber (see 4.5.2 ). True FxPath[] 2:FxPathElement Path to a UA FX Asset ... example, TargetType describes multiple targets (all instances of that ObjectType ), while the combination of SerialNumber , ProductCode , and ManufacturerUri uniquely identifies a single target. The following options can be used
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicessame device can lead to the situation, that the same Variable (e.g., the Property SerialNumber ) for the same device is used in several places. When the Property is the same
-
OPC-30120 – OPC UA for IO-Link Devices and IO-Link Masters - IO-Link: OPC Unified Architecture7.1.2 OverviewHasComponent Object 2:Identification FunctionalGroupType Mandatory HasComponent Object General FunctionalGroupType Mandatory HasProperty Variable 2:SerialNumber String PropertyType Optional HasProperty Variable 2:Manufacturer LocalizedText PropertyType Mandatory HasProperty Variable 2:Model LocalizedText ... Variable defined in Table 8 . Organizes VendorID Variable defined in Table 8 . Organizes 2:SerialNumber Variable defined in Table 8 . Organizes ApplicationSpecificTag Variable defined in Table 12 . Organizes FunctionTag Variable
-
OPC-30140 – OPC UA for PROFINET6.3.1.8.1 PnIdentificationTypeHasProperty Variable VendorId UInt16 PropertyType Mandatory HasProperty Variable OrderId String PropertyType Mandatory HasProperty Variable SerialNumber String PropertyType Mandatory HasProperty Variable SoftwareRevision String PropertyType Mandatory HasProperty Variable HardwareRevision String PropertyType Mandatory ... Method Source VendorId Read I&M0 | VendorID OrderId Read I&M0 | OrderID SerialNumber Read I&M0 | IM_Serial_Number SoftwareRevision Read I&M0 | IM_Software_Revision
-
OPC-30140 – OPC UA for PROFINET6.3.1.8.2 PnAssetTypeHasProperty Variable SoftwareRevision String PropertyType Optional HasProperty Variable HardwareRevision String PropertyType Optional HasProperty Variable SerialNumber String PropertyType Mandatory HasProperty Variable TypeIdentification UInt16 PropertyType Mandatory HasProperty Variable Organization UInt16 PropertyType Mandatory ... Software_Revision or AM_SoftwareRevision HardwareRevision Read AssetManagementData | IM_Hardware_Revision or AM_HardwareRevision SerialNumber Read AssetManagementData | IM_Serial_Number TypeIdentification Read AssetManagementData | AM_TypeIdentification Organization Read AssetManagementData | AM_DeviceIdentification.Organization VendorId
-
OPC-30140 – OPC UA for PROFINETB.1.1 PnDIDeviceTypeSoftware_Revision HardwareRevision Read I&M0 | IM_Hardware_Revision SerialNumber Read I&M0 | IM_Serial_Number RevisionCounter Read I&M0 | IM_Revision_Counter
-
OPC-30200 – OPC UA for Commercial Kitchen Equipment5.1.5 SerialNumber propertySerialNumber property The identification number, e.g. the serial number of the device, is provided as freely definable text in the SerialNumber property
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS4.1.1 Serial Number LifecycleSerial Number Lifecycle This document defines the serialization management OPC UA interfaces to support global regulation reporting requirements and the packaging serialization management process from the enterprise serialization manager ... intended market. The key concepts of OPEN-SCS PSS are Serial Numbers , Serial Number Collections , Label Collections and Serialized Identifiers . A Serial Number is a string of characters with
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS4.1.2 Serialization Activitiesperformed for each level of a packaging aggregation hierarchy, such as separate serial number management, provisioning, printing, and commissioning for pallet labels, and similar activities for cases and cartons ... communication exchanges are shown in Figure 2 . Figure 2 - Activities in Serialization Global Serial Number Management - This is the activity of creating, allocating, registering, and general management of Serial Numbers
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCSSerial Number Information Model The information objects identified in Figure 3 are used to describe the information used in the serialization services. SID Class - An SID Class represents information specified ... global industry standards, governmental standards or regulation used in representation of a Serial Number in an SID. Each standard or regulation defines one or more SID Classes including the specification
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCSSerial Number State and Event Model The state and event model for a Serial Number shall follow the model displayed in Figure 4 . Note 1 The state is managed ... applications to manage their internal state representation. Note 2 All Serial Numbers in a Serial Number Collection only contain Serial Numbers with the same state. Note 3 All Serial Numbers
-
OPC-30260 – OPC UA for OPEN-SCS - Serialization Object Model: OPEN-SCS7.1 Profile OverviewAggregation Event Manager Server Profile Receives OPEN-SCS Aggregation events AggregationPackingEvent AggregationUnpackingEvent MaxAggregationEvents Allocated Serial Number Manager Client Profile Sends reserved serial numbers to a Print and Commission Manager Server ... serial number events Uses SNtoAllocated Allocated Serial Number Manager Server Profile Manages reserved serial numbers SNRequestAllocated SNToAllocated PoolSelectionCriteria SerialNumberFormat MaxSNRequestable MaxSNReturnable MaxSNPushable Label Event Manager Client Profile Send OPEN
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical IntegrationArchitecture for Devices (DI), inheriting the InstanceDeclarations of that Node 0:HasProperty Variable 2:SerialNumber 0:String 0:PropertyType M 0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType ... PowerTrainType MP AdditionalComponents 0:HasComponent Object <AdditionalComponentIdentifier> 0:BaseObjectType MP The SerialNumber property is a unique production number assigned by the manufacturer of the device. This is often
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.5.2 MotorType definitionArchitecture for Devices (DI), inheriting the InstanceDeclarations of that Node 0:HasProperty Variable 2:SerialNumber 0:String 0:PropertyType M 0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType ... AnalogUnitType M 2:ParameterSet 0:HasComponent Variable EffectiveLoadRate 0:UInt16 0:BaseDataVariableType O The SerialNumber property is a unique production number assigned by the manufacturer of the device. This
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.6.2 GearType definitionArchitecture for Devices (DI), inheriting the InstanceDeclarations of that Node 0:HasProperty Variable 2:SerialNumber 0:String 0:PropertyType M 0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType ... possible to use these values to transform between axis and motor movements. The SerialNumber property is a unique production number assigned by the manufacturer of the device. This is often
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.18.2 ControllerType definitionComponentType defined in OPC Unified Architecture for Devices (DI) 0:HasProperty Variable 2:SerialNumber 0:String 0:PropertyType M 0:HasProperty Variable 2:Manufacturer 0:LocalizedText 0:PropertyType ... AnalogUnitType O 2:ParameterSet 0:HasComponent Variable Temperature 0:Double 0:AnalogUnitType O The SerialNumber property is a unique production number assigned by the manufacturer of the device. This
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical IntegrationPartly Completed Machinery according Machinery Directive 2006/42/EU for robots provides the Model and the SerialNumber for the robot and for the controller. Figure C. 21 - Example Finding all Machines
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset ManagementAsset Identification Supports the PtAssetType (or subtype) and its mandatory properties (i.e. Manufacturer and SerialNumber ). Server Powertrain Asset Identification Writable Tag Supports the PtAssetType (or subtype) with all its writable