Search
12 result(s) for RIO Output Channel
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.1 RioPaAnalogOutputChannelTypeRioPaAnalogOutputChannelType The RioPaAnalogOutputChannelType provides access to the data of an analog RIO Output Channel according to RIOforPA. Table 38 - RioPaAnalogOutputChannelType Attribute Value BrowseName RioPaAnalogOutputChannelType IsAbstract False References Node Class BrowseName ... used as Output value in place of the Process Value if the SimulationEnabled Variable contains True. The Config Variable contains the configuration properties available for the RIO Channel
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.6 RioFaAnalogOutputChannelTypeRioFaAnalogOutputChannelType The RioFaAnalogOutputChannelType provides access to the data of an analog RIO Output Channel according to RIOforFA. Table 43 - RioFaAnalogOutputChannelType Attribute Value BrowseName RioFaAnalogOutputChannelType IsAbstract False References Node Class BrowseName ... Variable contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.1 RioPaDigitalOutputChannelTypeRioPaDigitalOutputChannelType The RioPaDigitalOutputChannelType provides access to the data of a discrete RIO Output Channel according to RIOforPA. Table 50 - RioPaDigitalOutputChannelType Attribute Value BrowseName RioPaDigitalOutputChannelType IsAbstract False References Node Class BrowseName ... used as Output value in place of the Process Value if the SimulationEnabled Variable contains True. The Config Variable contains the configuration properties available for the RIO Channel
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.6 RioFaDigitalOutputChannelTypeRioFaDigitalOutputChannelType The RioFaDigitalOutputChannelType provides access to the data of a discrete RIO Output Channel according to RIOforFA. Table 55 - RioFaDigitalOutputChannelType Attribute Value BrowseName RioFaDigitalOutputChannelType IsAbstract False References Node Class BrowseName ... Variable contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaDigitalOutputConfigVariableType The RioPaDigitalOutputConfigVariableType represents the configuration of a digital RIO Output Channel according to RIO PA . Table 71 - RioPaDigitalOutputConfigVariableType Definition Attribute Value BrowseName RioPaDigitalOutputConfigVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaDigitalOutputConfigVariableType The RioFaDigitalOutputConfigVariableType represents the configuration of a digital RIO Output Channel according to RIO FA . Table 72 - RioFaDigitalOutputConfigVariableType Definition Attribute Value BrowseName RioFaDigitalOutputConfigVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaAnalogOutputConfigVariableType The RioPaAnalogOutputConfigVariableType represents the configuration of an analog RIO Output Channel according to RIO PA . Table 75 - RioPaAnalogOutputConfigVariableType Definition Attribute Value BrowseName RioPaAnalogOutputConfigVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaAnalogOutputConfigVariableType The RioFaAnalogOutputConfigVariableType represents the configuration of an analog RIO Output Channel according to RIO FA . Table 76 - RioFaAnalogOutputConfigVariableType Definition Attribute Value BrowseName RioFaAnalogOutputConfigVariableType IsAbstract False ValueRank -1 (-1 = Scalar
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaDigitalOutputConfigDataType The RioPaDigitalOutputConfigDataType represents the configuration of a digital RIO Output Channel according to RIO PA . Table 81 - RioPaDigitalOutputConfigDataType Structure Name Type Description RioPaDigitalOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaDigitalOutputConfigDataType The RioFaDigitalOutputConfigDataType represents the configuration of a digital RIO Output Channel according to RIO FA . Table 83 - RioFaDigitalOutputConfigDataType Structure Name Type Description RioFaDigitalOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled
-
OPC-30142 – OPC UA for PROFINET Remote IORioPaAnalogOutputConfigDataType The RioPaAnalogOutputConfigDataType represents the configuration of an analog RIO Output Channel according to RIO PA . Table 89 - RioPaAnalogOutputConfigDataType Structure Name Type Description RioPaAnalogOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled
-
OPC-30142 – OPC UA for PROFINET Remote IORioFaAnalogOutputConfigDataType The RioFaAnalogOutputConfigDataType represents the configuration of an analog RIO Output Channel according to RIO FA . Table 91 - RioFaAnalogOutputConfigDataType Structure Name Type Description RioFaAnalogOutputConfigDataType structure SignalType RioSignalTypeEnumeration Signal Type. WireCheckEnabled