Search
18 result(s) for Operation
-
OPC-10000-21 – OPC Unified Architecture - Part 21: Device Onboarding4.3.4 ConfigurationSome Devices may allow individual Applications to be configured while other Applications continue in Operation state described
-
OPC-10000-21 – OPC Unified Architecture - Part 21: Device Onboarding4.3.5 OperationOperation Operation occurs when one or more Applications on a Device are running normally performing whatever task it was deployed to do. In this stage it is possible to update
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3this Attribute is server specific. Servers only supporting the use cases Observation and Operation are typically setting this Attribute to 0 or are not providing this optional Attribute . Servers supporting
-
OPC-30000 – OPC UA for Programmable Logic Controllers based on IEC61131-3Entry point for Observation and Operation (Examples) The entry point for UA client for the use cases Observation and Operation is the Objects Folder . One typical entry point ... Such an example is shown in Figure 27 . Figure 27 - Browse entry point for Operation with Ctrl Resource Servers that want to hide some of the components of a Ctrl
-
OPC-30020 – MDIS OPC UA Companion SpecificationMDISBaseObjectType 0:HasComponent Variable Running 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable Operation MotorOperationEnum 0:BaseDataVariableType M, RO 0:HasComponent Variable NonDefeatableStartInterlock 0:Boolean 0:BaseDataVariableType ... running (or not). If the motor is running it returns True. Operation - There are three different operation modes: Auto , Manual and Off . In Auto operation the process sends the Start
-
OPC-30020 – MDIS OPC UA Companion Specification6.11.6 Motor SetOperation MethodMotor SetOperation Method SetOperation Method is used to set the Operation of the Motor. Signature: SetOperation ( [in] MotorOperationEnum Mode); Table 81 - SetOperation Method Arguments Argument Description Mode Mode to operate ... described in Table 124 for ease of reference. Comments The SetOperation Method commands the Operation . Table 82 specifies the AddressSpace representation for the SetOperation Method . Table 82 - SetOperation AddressSpace Definition
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 Serverflag. Server MDIS Motor SetOperation Supports the optional aspect of the MDISMotorObjectType related to Operation , this includes the SetOperation Method . Server MDIS Motor Start/Stop Supports the optional Start and Stop ... Methods of the MDISMotorObjectType, this includes supporting Manual Operation . Server MDIS Motor DefeatableStartInterlock Supports the optional aspect of the MDISMotorObjectType related to DefeatableStartInterlock . This includes DefeatableStartInterlock flag and providing
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management1 Scopeasset components can be represented. Future parts will address the following topics: Functional operation data Information about the current status and operating values are required by vertical higher-level systems ... monitoring Condition monitoring is the process of determining the condition of machinery while in operation , in order to identify a significant change which is indicative of a developing fault. This
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Managementstop a motor in combination with suitable overload protection. IEC 60947-4-1 Operation Combination of activities necessary to permit an installation to function. NOTE - Operation includes matters as switching
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.3.15.1 Overviewdescribes a device designed to respond to temperature providing an electrical signal or mechanical operation and that is operated in a powertrain and is formally defined in Table
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.4.1 OverviewOverview The PtMotorRatedAttributesType provides common operation modes and related asset attributes of a base motor type and is formally defined in Table 69 . These rated asset attributes provide a consistent ... asset attribute set for a specific operation point of a motor. Table 69 - PtMotorRatedAttributesType Definition Attribute Value BrowseName PtMotorRatedAttributesType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.4.2 Object Descriptionunder normal conditions without damage or safety risks, or the power intended for normal operation . The unit shall be watt [W]. MotorPowerFactor provides the phase shift between voltage ... amount of active power to the apparent power in the rated torque and speed operation point. MotorWindingType provides how the three (or more) connections of the winding will be connected
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.5.1 OverviewOverview The PtMotorRotaryRatedAttributesType provides common operation modes and related asset attributes of a rotary motor and is formally defined in Table 71 . These rated asset attributes provide a consistent asset ... attribute set for a specific operation point of a motor. Table 71 - PtMotorRotaryRatedAttributesType Definition Attribute Value BrowseName PtMotorRotaryRatedAttributesType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.6.1 OverviewOverview The PtMotorLinearRatedAttributesType provides common operation modes and related asset attributes of a linear motor and is formally defined in Table 72 . These rated asset attributes provide a consistent asset ... attribute set for a specific operation point of a motor. Table 72 - PtMotorLinearRatedAttributesType Definition Attribute Value BrowseName PtMotorLinearRatedAttributesType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.7.2 Object DescriptionValue": 5, "DisplayName": "S6", "Description": "Continuous operation with intermittent load" }, { "Value": 6, "DisplayName ... Description": "Continuous operation periodic duty with electric braking" }, { "Value": 7, "DisplayName": "S8", "Description": "Continuous operation with periodic changes
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.8.14.2 Object Type Descriptionduty cycle of the brake, e.g. continuous (S1), short-time (S2) or intermittent (S3) operation . BrakeCoolingMethod provides the information which cooling method is used to cool the brake
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.9.9.2 Object Descriptionunit shall be volts [V]. PreChargeTimeout is the time limit of the pre-charge operation . The pre-charge starts operating when it detects an applied voltage and stops operating after
-
OPC-40400-1 – OPC UA for the Powertrain - Part 1: Asset Management7.11.15.1 OverviewOverview The PtMechanicalStrengthAttributesType provides asset attributes describing the mechanical strength during operation and is formally defined in Table 151 . Table 151 - PtMechanicalStrengthAttributesType Definition Attribute Value BrowseName PtMechanicalStrengthAttributesType IsAbstract False References