OPC-34100 – OPC UA for Energy Consumption ManagementEnergyMeasurementValueType VariableType Definition The EnergyMeasurementValueType is a subtype of BaseDataVariableType . It is used to provide an individual energy measurement value. It is formally defined in Table 39 . Table 39 - EnergyMeasurementValueType ... Definition Attribute Value BrowseName EnergyMeasurementValueType IsAbstract False ValueRank -2 (-2 = Any) DataType BaseDataType References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseDataVariableType 0:HasProperty Variable AccuracyDomain
-
OPC-34100 – OPC UA for Energy Consumption Management6.2.1 Base Conceptsmeasurements measured at the same point in a system represented by Variables of VariableType EnergyMeasurementValueType . Those Objects may have a Method to reset the aggregated values. How those Objects ... device or a machine) is not addressed by this specification. The EnergyMeasurementValueType provides additional meta data of the measurement like the engineering unit. In Figure 8 , an overview
-
OPC-34100 – OPC UA for Energy Consumption ManagementAccuracy Domains and Classes Individual measurements ( Variables of EnergyMeasurementValueType ) have a specific accuracy class defined by a specific accuracy domain. This specification defines accuracy domains in a way, that ... Property containing the different accuracy classes defined by the accuracy domain. Each measurement of EnergyMeasurementValueType references its accuracy domain by the Property AccuracyDomain of DataType NodeId . The accuracy class
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.1 IEnergyProfileE0TypeIEnergyProfileE0Type The IEnergyProfileE0Type contains the References to EnergyMeasurementValueType Variables needed for EnergyProfile E0. Table 18 - IEnergyProfileE0Type Definition Attribute Value BrowseName IEnergyProfileE0Type IsAbstract True References Node Class BrowseName DataType TypeDefinition Other ... Subtype of the 0:BaseInterfaceType 0:HasComponent Variable AcCurrentPe AcPeDataType EnergyMeasurementValueType M Conformance Units ECM EnergyProfile E0 Table 19 - IEnergyProfileE0Type Attribute values for child Nodes Source Path Value Attribute AcCurrentPe
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.2 IEnergyProfileE1TypeIEnergyProfileE1Type The IEnergyProfileE1Type contains the References to EnergyMeasurementValueType Variables needed for EnergyProfile E1. Table 20 - IEnergyProfileE1Type Definition Attribute Value BrowseName IEnergyProfileE1Type IsAbstract True References Node Class BrowseName DataType TypeDefinition Other ... Subtype of the 0:BaseInterfaceType 0:HasComponent Variable AcActivePowerTotal 0:Float EnergyMeasurementValueType M Conformance Units ECM EnergyProfile E1 Table 21 - IEnergyProfileE1Type Attribute values for child Nodes Source Path Value Attribute
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.3 IEnergyProfileE2TypeIEnergyProfileE2Type The IEnergyProfileE2Type contains the References to EnergyMeasurementValueType Variables needed for EnergyProfile E2. Table 22 - IEnergyProfileE2Type Definition Attribute Value BrowseName IEnergyProfileE2Type IsAbstract True References Node Class BrowseName DataType TypeDefinition Other ... Subtype of the 0:BaseInterfaceType 0:HasComponent Variable AcActivePowerTotal 0:Float EnergyMeasurementValueType M 2:HasStatisticComponent Variable AcActiveEnergyTotalImportLp 0:Float EnergyMeasurementValueType M 2:HasStatisticComponent Variable AcActiveEnergyTotalExportLp 0:Float EnergyMeasurementValueType M Conformance
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.4 IEnergyProfileE3TypeIEnergyProfileE3TypeThe IEnergyProfileE3Type contains the References to EnergyMeasurementValueType Variables needed for EnergyProfile E3. Table 24 - IEnergyProfileE3Type Definition Attribute Value BrowseName IEnergyProfileE3Type IsAbstract True References Node Class BrowseName DataType TypeDefinition Subtype ... BaseInterfaceType 0:HasComponent Variable AcActivePowerPe AcPeDataType EnergyMeasurementValueType M 0:HasComponent Variable AcReactivePowerPe AcPeDataType EnergyMeasurementValueType M 2:HasStatisticComponent Variable AcActiveEnergyTotalImportHp 0:Double EnergyMeasurementValueType M 2:HasStatisticComponent Variable AcActiveEnergyTotalExportHp 0:Double EnergyMeasurementValueType
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.5 IEnergyProfileD0TypeIEnergyProfileD0Type The IEnergyProfileD0Type Interface contains a Reference to a EnergyMeasurementValueType Variable representing direct current ( EnergyProfile D0). Table 26 - IEnergyProfileD0Type Definition Attribute Value BrowseName IEnergyProfileD0Type IsAbstract True References Node Class BrowseName ... DataType TypeDefinition Other Subtype of the 0:BaseInterfaceType 0:HasComponent Variable DcCurrent 0:Float EnergyMeasurementValueType M Conformance Units ECM EnergyProfile D0 Table 27 - IEnergyProfileD0Type Attribute values for child Nodes Source
-
OPC-34100 – OPC UA for Energy Consumption Management7.1.3.6 IEnergyProfileD1TypeIEnergyProfileD1Type The IEnergyProfileD1Type Interface contains the References to EnergyMeasurementValueType Variables representing measurements for equipment that produces or consumes direct current. Table 28 - IEnergyProfileD1Type Definition Attribute Value BrowseName IEnergyProfileD1Type IsAbstract True ... DataType TypeDefinition Other Subtype of the 0:BaseInterfaceType 0:HasComponent Variable DcCurrent 0:Float EnergyMeasurementValueType M 0:HasComponent Variable DcVoltage 0:Float EnergyMeasurementValueType M 0:HasComponent Variable DcActivePower 0:Float