Search
13 result(s) for Double
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model12.2.9.2 DoubleDouble The representation in the AddressSpace of the Double DataType is defined in Table 174 . Table 174 - Double definition Attributes Value BrowseName Double IsAbstract FALSE References NodeClass BrowseName DataType TypeDefinition
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Modelproducts. Examples of Built-in DataTypes are Int32 (see 8.26 ) and Double (see 8.12 ). Simple DataTypes are subtypes of the Built-in DataTypes , which are handled on the wire like ... Simple DataType is Duration . It is handled on the wire as a Double but the Client can read the DataType Attribute and thus interpret the value as defined by Duration
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.13 DurationDuration This Simple DataType is a Double that defines an interval of time in milliseconds (fractions can be used to define sub-millisecond values). Negative values are generally invalid
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services7.7.3 FilterOperatorrestricted to the DataTypes Byte , Int16 , Int32 , Int64 , SByte , UInt16 , UInt32 , UInt64 , Float , Double and DateTime . When testing for equality, a Server shall treat null and empty arrays ... Table 121 - Conversion rules Target Type (To) Source Type (From) Boolean Byte ByteString DateTime Double ExpandedNodeId Float Guid Int16 Int32 Int64 NodeId SByte StatusCode String LocalizedText QualifiedName UInt16 UInt32 UInt64
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.4.2.4 Floating-pointFloating-point Normal Float and Double values shall be encoded as a JSON number. Special floating-point numbers such as positive infinity (INF), negative infinity (-INF) and not-a-number
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsRevisedLifetime is a UInt32 value representing the number of milliseconds instead of the Double ( Duration ) defined in OPC 10000-4 . This optimization is possible because sub-millisecond timeouts
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.6.1 Overviewdescription of the DataTypes defined in this specification. DataTypes like String , Boolean , Double or LocalizedText are defined in OPC 10000-3 . Their representation is specified
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.2.6.2 PublishingIntervalinto the buffer are discarded. The Duration DataType is a subtype of Double and allows configuration of intervals smaller than a millisecond
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.3.1.1.5 SamplingOffsettime for sending at the PublishingOffset . The Duration DataType is a subtype of Double and allows configuration of intervals smaller than a millisecond
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub6.3.1.1.6 PublishingOffsettiming inside the PublishingInterval is application specific. The Duration DataType is a subtype of Double and allows configuration of intervals smaller than a millisecond. Figure 31 depicts how the different
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.19.2.1 Variable HighLimitVariable HighLimit This OPC UA Property, of DataType Double , is the HighLimit parameter for the object's event algorithm. The HighLimit value represents the upper limit of the range considered
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.19.2.2 Variable LowLimitVariable LowLimit This OPC UA Property, of DataType Double , is the LowLimit parameter for the object's event algorithm. The LowLimit value represents the lower limit of the range considered
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model8.19.2.3 Variable DeadbandVariable Deadband This OPC UA Property, of DataType Double , is the Deadband parameter for the object's event algorithm. The Deadband variable value represents the deadband that is applied