Search
8 result(s) for ControlledParameterType
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type DefinitionsControlledParameterType The ControlledParameterType is used for process parameters that are controlled by the client by writing a set value and optional ramps and parameters for closed loop control. Table ... ControlledParameterType Definition Attribute Value BrowseName ControlledParameterType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of MonitoredParameterType 0:HasComponent Variable SetRampUp 0:Double 0:AnalogItemType O, RW 0:HasComponent
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devicesSubtype of 0: BaseObjectType defined in OPC UA Part 5 0:HasComponent Object Temperature ControlledParameterType M 0:HasComponent Variable InternalMeasuringPoint 0:UInt16 0:MultiStateValueDiscreteType O, RW 0:HasComponent Variable StandbyTemperature ... Parameter is not only monitored but controlled, the subtype ControlledParameterType can be used
-
OPC-40082-1 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 1: Temperature control devices10.25 ExternalChannelTypeParameter is not only monitored but controlled, the subtype ControlledParameterType can be used
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesTemperature which has the HRDTemperatureType as type definition. This is derived from the ControlledParameterType which is defined in OPC 40083 BrowseName Namespace Namespace index Remarks HRD_Inglass_0123456 Local Server
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesHRDTemperatureType The ControlledParameterType as defined in OPC 40083 is used for process parameters that are controlled by the client by writing a set value and optional ramps and parameters ... closed loop control. For HRD the HRDTemperatureType is derived from the ControlledParameterType .The Variables SecondSetValue , BoostSetValue, BoostTime, StandbySetValue, ActiveSetValue and TimeMethodPIDParameters are added. The SecondSetValue can be used for various
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systemssystems with DeliveryPressure the components ActualValue , SetValue , UpperTolerance and LowerTolerance defined in the ControlledParameterType are mandatory. If the upper or lower tolerance band is passed it is documented
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems13.1 Conformance UnitsServer OPC 40083 Tolerances Support of Status, UpperTolerance and LowerTolerance in the MonitoredParameterType and ControlledParameterType and the according alarms. Server OPC 40082-3 DosingFunction Support of StartDosing, StopDosing and DosingActive
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions32.2 MeasuringDeviceTypeValue BrowseName MeasuringDeviceType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of ControlledParameterType 0:HasProperty Variable Id 0:String 0:PropertyType M, RO 0:HasProperty Variable Name