OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.2 BaseEventTypeHasProperty Variable Message LocalizedText PropertyType Mandatory HasProperty Variable Severity UInt16 PropertyType Mandatory HasProperty Variable ConditionClassId NodeId PropertyType Optional HasProperty Variable ConditionClassName LocalizedText PropertyType Optional HasProperty Variable ConditionSubClassId NodeId[] PropertyType Optional ... consistent manner. Additional discussions of severity can be found in OPC 10000-9 . ConditionClassId specifies in which domain this Event is used. It is the NodeId of the corresponding subtype
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model5.1 Overviewgenerated internally. It can also contain LogRecords that result from Events that have a ConditionClassId or ConditionSubClassId of LogEntryConditionClassType that are reported by the Object on which the LogObject instance
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.1 Conceptscapability to collect all Events that the parent Object receives that have a ConditionClassId or SubConditionClassId of LogEntryConditionClass . For example, since Events / Conditions / Alarms instance can be defined ... include all Events that would be available from the Area2 Object that have a ConditionClassId or ConditionSubClassId of LogEntryConditionClass . In addition the LogObject could store additional fields from Events
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject ModelEvent to be recorded in the LogObject is for the Event to have a ConditionClassId or SubConditionClassId of LogEntryConditionClass . The following describes fields in BaseEventType that are mapped
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Model6.3 BaseLogEventTypePropertyType O 0:HasProperty Variable ErrorCodeNode 0:NodeId 0:PropertyType O 0:HasProperty Variable ConditionClassId 0:NodeId 0:PropertyType M 0:HasProperty Variable ConditionClassName 0:LocalizedText 0:PropertyType ... null if no specific Node is related to the LogRecord . The ConditionClassId and ConditionClassName in BaseEventType are made mandatory in this EventType . The ConditionClassId shall be set to LogEntryConditionClassType . TraceContext
-
OPC-10000-26 – Part 26: LogObject - Part 26: LogObject Modelstorage of LogRecords in any LogObject ). The Event history storage would include the ConditionClassId ( SubConditionClassId ) field in an event and a GetRecords call could just be a retrieval from ... history for fields they are interested in and a filter for records where the ConditionClassId / SubConditionClassId is LogEntryConditionClassType. The filter might also include restriction for records that are from
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelServer Object . If AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Audit Event being mapped to LogObject records
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConnection ). If AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records. The RemovedEndpoint
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelthis Type. If ConnectionManagerLog or AutomationComponentLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelprocess the ConnectionConfigurationSet . If ConnectionManagerLog is supported, this AuditEvent shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the AuditEvent being mapped to LogObject records. This
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConformanceUnits UAFX ConnectionManager LogObject Events This EventType inherits all Properties of the BaseLogEventType . The ConditionClassId shall be set to LogEntryConditionClassType . SourceNode shall be the NodeId of the ConnectionConfigurationSet that ... related to the LogRecord. If ConnectionManagerLog is supported, this Event shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Event being mapped to LogObject records
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelConformanceUnits UAFX ConnectionManager LogObject Events This EventType inherits all Properties of the BaseLogEventType . The ConditionClassId shall be set to LogEntryConditionClassType . SourceNode shall be the NodeId of the ConnectionConfigurationSet that ... with the close activity. If ConnectionManagerLog is supported, this Event shall set either the ConditionClassId or a ConditionSubClassId to LogEntryConditionClassType , which results in the Event being mapped to LogObject records
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics12.1 Overviewallow clients to easily identify or filter for maintenance activities, the 0: ConditionClassId is used as defined for conditions in OPC 10000-9 . Maintenance activities shall use the 0: MaintenanceConditionClassType ... subtype as 0: ConditionClassId . In 12.4 , specific 0: ConditionClassIds are defined. Companion specifications or vendors might create subtypes of 0: MaintenanceConditionClassType or its subtypes for a more detailed classification
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics12.4.1 Overviewactivities can be classified into different categories. This specification uses the mechanism of the ConditionClassId defined for conditions in OPC 10000-9 , for such a classification of maintenance activities ... following, specific subtypes of MaintenanceConditionClassType are defined, that should be used as ConditionClassId for specific maintenance activities. Other companion specifications and vendors might add additional subtypes of MaintenanceConditionClassType and might
-
OPC-30210-1 – OPC UA for Unattended Retail & Coffee Solutions - Part 1: Core Components7.26.2 ObjectType definitionSeverity shall be in the range of 201 to 400. The optional Properties LocalTime , ConditionClassId , ConditionClassName , ConditionSubCassId and ConditionSubClassName should be omitted. The mandatory InMaintenanceMode indicates whether the Event
-
OPC-30210-1 – OPC UA for Unattended Retail & Coffee Solutions - Part 1: Core Components7.29.2 ObjectType definitionSeverity shall be in the range of 401 to 600. The optional Properties LocalTime , ConditionClassId , ConditionClassName , ConditionSubCassId and ConditionSubClassName should be omitted
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Managementtool. The events can be found in the information model as InterruptionConditionType with its ConditionClassId and ConditionClassName (that specify the reason for the interruption further), and the StartTime and EndTime
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementInterruptionConditionType can be sent. The type of interruption can be classified using the variables ConditionClassId and ConditionClassName