10.6 MaterialSupport
Provides the process values of the material support system.

10.6.1 ActiveVacuumUnits
Information about the activity of the vacuum units. The array length shall match the total number of vacuum units given in the VacuumUnitsQuantity Property in the MachineConfigurationType.
The ActiveVacuumUnitsDataType is defined in chapter 10.6.1.1.
10.6.1.1 ActiveVacuumUnitsDataType
This structured DataType provides information about the position of a vacuum unit and the current vacuum power, given as a float value between 0 (off) and 1 (full power).
| Name | Type | Description |
| ActiveVacuumUnitsDataType | structure | Subtype of 0:Structure defined in OPC 10000-5 |
Position | 0:String | Information about the position (location) of the vacuum unit. |
VacuumPower | 0:Float | Indication about the relative power of the vacuum unit. Range from 0 to 1. |
10.6.2 SideFixtureActive
Boolean. Indicates if the side fixture is active (true) or not (false).
10.6.3 TopFixtureActive
Boolean. Indicates if the top fixture is active (true) or not (false).
10.6.4 Orientation
Provides information about the actual orientation in degrees (°) of the material support system.