OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model8.4 LocaleIdletter ISO 3166 code for the country/region. The rules for constructing LocaleIds defined by RFC 5646 are restricted as follows: this specification permits only zero or one <country/region ... used. This format is defined in 8.5 . Table 26 shows examples of OPC UA LocaleIds . Clients and Servers always provide LocaleIds that explicitly identify the language and the country/region. Table
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesLocale Negotiation A number of Services expect an array of LocaleIds which are used by a Server to determine in what language or languages LocalizedText should be returned. The array ... LocaleIds is in the preferred order the Client would like the Server to use when selecting the locale of the LocalizedText to be returned. The first LocaleId in the list
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.5.4.1 DescriptionClient may reduce the number of results returned by specifying filter criteria based on LocaleIds and Transport Profile URIs. The Server returns an empty list if no Endpoints match
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.7.3.2 ParametersclientSoftwareCertificates [] SignedSoftwareCertificate Reserved for future use. The SignedSoftwareCertificate type is defined in 7.37 . localeIds [] LocaleId List of locale ids to use. See locale negotiation in 5.4 which applies to this ... Session . If it is null or empty the Server shall keep using the current localeIds for the Session . userIdentityToken Extensible Parameter UserIdentityToken The credentials of the user associated with
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessServers can configure multiple additional locales for each displayName . However, if none of the LocaleIds specified by the Client for the Session matches these additional locales, the Server shall return ... Servers can configure multiple additional locales for each description . However, if none of the LocaleIds specified by the Client for the Session matches these additional locales, the Server shall return
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessServers can configure multiple additional locales for each displayName . However, if none of the LocaleIds specified by the Client for the Session matches these additional locales, the Server shall return ... Servers can configure multiple additional locales for each description . However, if none of the LocaleIds specified by the Client for the Session matches these additional locales, the Server shall return
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.6.3 WriterGroupTypeHasProperty Variable KeepAliveTime Duration PropertyType Mandatory HasProperty Variable Priority Byte PropertyType Mandatory HasProperty Variable LocaleIds LocaleId[] PropertyType Mandatory HasProperty Variable HeaderLayoutUri String PropertyType Mandatory HasComponent Object TransportSettings WriterGroupTransportType Optional HasComponent ... KeepAliveTime is defined in 6.2.6.3 . The Priority is defined in 6.2.6.4 . The LocaleIds parameter is defined in 6.2.6.5 . The HeaderLayoutUri is defined in 6.2.6.6 . The transport protocol mapping specific setting
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelrecommendations in OPC 10000-14 . For UADP-PeriodicFixed, KeepAliveTime should be set to PublishingInterval . LocaleIds can be set to a value different from null if the translation of Strings will
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices3.3.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics3.3.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-10000-120 – OPC Unified Architecture - Part 120: OPC UA and XML Data Type Mapping3.3.3.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-10000-200 – OPC Unified Architecture - Part 200: Industrial Automation3.3.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-10000-210 – OPC Unified Architecture - Part 210: Relative Spatial Location3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-10000-211 – OPC Unified Architecture - Part 211: Global Positioning3.4.3.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job Control3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition3.4.2.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-30060 – OPC UA for Tobacco Machine Communication3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™3.4.3.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>3.3.5.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30141 – OPC UA for PROFIenergy3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30142 – OPC UA for PROFINET Remote IO3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30143 – OPC UA for PROFINET Encoder - Part <mm>: <Part Name>3.5.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model3.4.3.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drives3.5.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics3.4.3.1 Generalunless specified differently in the specification. Whether the Server provides translated names for other LocaleIds is server specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect
-
OPC-40210 – OPC UA for Geometric Measurement Systems4.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management3.4.3.1 GeneralLocaleId "en". Whether the server provides translated names for other LocaleIds are server-specific. Description Optionally a server-specific description is provided. NodeClass Shall reflect the NodeClass