8 result(s) for Transducer
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.1 RioPaAnalogInputChannelTypesignal value obtained by reading the input signal through the signal coupling in the Transducer . The Mode Variable contains the current mode of operation encoded as RioChannelModeEnumeration . If Mode
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.6 RioFaAnalogInputChannelTypesignal value obtained by reading the input signal through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.1 RioPaAnalogOutputChannelTypeVariable contains the readback value obtained by reading the output signal back through the Transducer and the Function Block . The SignalValue Variable contains the output signal value ... signal coupling in the Transducer . The SignalValueReadback Variable contains the output signal read back through the signal coupling in the Transducer . The Mode Variable contains the current mode of operation
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.6 RioFaAnalogOutputChannelTypeVariable contains the readback value obtained by reading the output signal back through the Transducer and the Function Block . The SignalValue Variable contains the output signal value ... signal coupling in the Transducer . The SignalValueReadback Variable contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.1 RioPaDigitalInputChannelTypesignal value obtained by reading the input signal through the signal coupling in the Transducer . The Mode Variable contains the current mode of operation encoded as RioChannelModeEnumeration . If Mode
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.6 RioFaDigitalInputChannelTypesignal value obtained by reading the input signal through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.1 RioPaDigitalOutputChannelTypeVariable contains the readback value obtained by reading the output signal back through the Transducer and the Function Block . The SignalValue Variable contains the output signal value ... signal coupling in the Transducer . The SignalValueReadback Variable contains the output signal read back through the signal coupling in the Transducer . The Mode Variable contains the current mode of operation
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.6 RioFaDigitalOutputChannelTypeVariable contains the readback value obtained by reading the output signal back through the Transducer and the Function Block . The SignalValue Variable contains the output signal value ... signal coupling in the Transducer . The SignalValueReadback Variable contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available