Search
12 result(s) for SimulationValue
-
OPC-30081 – OPC UA for Process Automation Devices - PA-DIM™define the unit for the AnalogSignalVariableType instance and also for its ActualValue and SimulationValue component Variables . In addition, each EngineeringUnits Property shall provide a HasDictionaryEntry reference to the IEC Common
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.3.2 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of array elements of the SimulationValue array Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] RioAnalogDataType Value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.1.5.2 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of array elements of the SimulationValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:Boolean Value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.1 RioPaAnalogInputChannelTypeHasComponent Variable SimulationEnabled 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable SimulationValue RioPaAnalogValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaAnalogInputConfigDataType RioPaAnalogInputConfigVariableType M, RO 0:HasComponent Method SetMode ... defined by this profile. The SimulationEnabled Variable contains True if the Value of the SimulationValue Variable shall be used as Process Value , otherwise False. The SimulationValue Variable contains the value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.5 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of the SimulationValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] RioAnalogDataType Value [in] 0:Byte Qualifier ); Argument Description ... Value Desired content of the Value struct member of the SimulationValue Variable . Qualifier Desired content of the Qualifier struct member of the SimulationValue Variable . The Method Result Codes (defined
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.5 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of the SimulationValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:RioAnalogDataType Value [in] 0:Byte Qualifier ); Argument ... Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.1 RioPaDigitalInputChannelTypeHasComponent Variable SimulationEnabled 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable SimulationValue RioPaDigitalValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaDigitalInputConfigDataType RioPaDigitalInputConfigVariableType M, RO 0:HasComponent Method SetMode ... defined by this profile. The SimulationEnabled Variable contains True if the Value of the SimulationValue Variable shall be used as Process Value , otherwise False. The SimulationValue Variable contains the value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.5 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of the SimulationValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:Boolean Value [in] 0:Byte Qualifier ); Argument ... Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.1 RioPaDigitalOutputChannelTypeHasComponent Variable SimulationEnabled 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable SimulationValue RioPaDigitalValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaDigitalOutputConfigDataType RioPaDigitalOutputConfigVariableType M, RO 0:HasComponent Method SetMode ... contains the Value MANUAL. The SimulationEnabled Variable contains True if the Value of the SimulationValue Variable shall be used as Process Value , otherwise False. The SimulationValue Variable contains the value
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.5 SetSimulationValue MethodSetSimulationValue Method This Method sets the Value of the SimulationValue Variable . The security constraints defined in chapter 6.7 apply. Signature SetSimulationValue ( [in] 0:Boolean Value [in] 0:Byte Qualifier ); Argument ... Description Value Desired content of the Value member of the SimulationValue Variable . Qualifier Desired content of the Qualifier member of the SimulationValue Variable . The Method Result Codes (defined in Call
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valuesprecision, ranges and unit of the process value. The optional Variables 3: ActualValue , 3: SimulationValue , and 3: SimulationState are used as defined in OPC 30081 and provide a simulation value
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process ValuesEURange , 0: EngineeringUnits and the optional 0: ValuePrecision , 0: InstrumentRange , 3: ActualValue , 3: SimulationValue and 3: SimulationState as defined in OPC 10000-8 and OPC 30081 . The PercentageValue Variable