OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices9.8 ActiveSetValuesValues for ActiveSetValues EnumValue ValueAsText Description 0 First Use of value stored as SetValue 1 Second Use of value stored as SecondSetValue 2 Standby Use of value stored as SetStandbyValue ... have a boost, for the others, the value of BoostSetValue is the same as SetValue . A server can provide manufacturer specific values with EnumValues ≥ 100. This is a central Variable
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devicesSwitchOff Switch hot runner off when disconnected 2 FirstSetValue Use of value stored as SetValue 3 SecondSetValue Use of value stored as SecondSetValue 4 Standby Use of value stored ... have a boost, for the others, the value of SecondSetValue is the same as SetValue . A server can provide manufacturer specific values with EnumValues ≥ 100. It is possible, that
-
OPC-40082-2 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 2: Hot runner devices16.4 EvenHeatUpEnabledEvenHeatUpEnabled Enables even heat-up process until nominal SetValue of Temperature of ZoneType is reached. This stands for a process for uniform heating of a mould. Many manufacturers
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systemselements shall always be used together. For systems with DeliveryPressure the components ActualValue , SetValue , UpperTolerance and LowerTolerance defined in the ControlledParameterType are mandatory. If the upper or lower tolerance band
-
OPC-40082-3 – OPC UA interfaces for plastics and rubber machinery - Peripheral devices - Part 3: LSR Dosing Systems9.12 DeliveryFlowrateDeliveryFlowrate For system with delivery volumetric flow rate the components ActualValue , SetValue , UpperTolerance and LowerTolerance are mandatory. If the upper or lower tolerance band is passed it is documented
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitions22.10 ResetMonitoringmonitoring sensitivity. This can be used e.g. after a process change with new SetValue to adapt the monitoring. Signature ResetMonitoring (); The method has no Input - or OutputArguments . Table 130 - ResetMonitoring
-
OPC-40083 – OPC UA for Plastics and Rubber Machinery - General Type Definitionsdown, which are only readable in the MonitoredParameterType , are writable in the ControlledParameterType . If SetValue (already writeable in MonitoredParameterType ) is changed by the client within the ControlledParameterType , the device shall