OPC-10000-15 – OPC Unified Architecture - Part 15: Safety3.1.2.14 SafetyBaseIDSafetyBaseID randomly generated authenticity ID which is used to safely authenticate SafetyProviders having the same SafetyProviderID Note 1 to entry: Together with the SafetyProviderID, it is an instance of connection
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetySafetyConsumers connect to SafetyProviders , they have prior expectations regarding the pair of SafetyProviderID and SafetyBaseID (e.g. by configuration). If this expectation is not fulfilled by the SafetyProvider , fail-safe substitute
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetyHasProperty Variable SafetyPubSubImplemented Boolean PropertyType Mandatory Conformance units SafetyProviderParameters The parameters for SafetyProviderID and SafetyBaseID exist in pairs for "Configured" and "Active" states: SafetyProviderIDConfigured and SafetyProviderIDActive ... offline; the values which have been set during runtime via the SAPI parameters ( SafetyProviderID , SafetyBaseID ); the corresponding "[...]Configured" values if the active values have been set to zero
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.3.3 SPI of SafetyProvidervalue which can be represented with sixteen octets All sixteenoctets are 0x00 R/W SafetyBaseID of the SafetyProvider that is normally used, see 3.1.2.14 and 9.1.1 . For dynamic systems, the safety ... program can overwrite this ID by providing a non-zero value at the input SafetyBaseID of the SafetyProvider 's SAPI . This runtime value can be queried using the SafetyBaseIDActive parameter
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.4.4 SPI of the SafetyConsumerrepresented with sixteen octets. All sixteen octets are 0x0 R/W The default SafetyBaseID of the SafetyProvider this SafetyConsumer uses to make a connection, see 3.1.2.14 . For dynamic systems, the safety ... program can overwrite this ID by providing a non-zero value at the input SafetyBaseID of the SafetyConsumer 's SAPI . This runtime value can be queried using the SafetyBaseIDActive parameter
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetysafe substitute values due to an incorrect ID. Operator acknowledgment is required. Mismatch of SafetyBaseID .2 0x11 B, E Yes SD_IDerrOA The SafetyConsumer has switched to fail-safe substitute ... shown when the error in the SPDU_ID is due to an incorrect SafetyBaseID . 3 This text may also be shown when the error in the SPDU
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety7.2.2.5 SafetyConsumer state diagramparameter SafetyConsumerID SPI_SafetyProviderID_i UInt32 Local variable to store the parameter SafetyProviderID SPI_SafetyBaseID_i UInt128 Local variable to store the parameter SafetyBaseID SPI_SafetyStructureSignature_i UInt32 Local variable ... uint32 ProviderID const uint32 SafetyProviderLevel_ID:= … // see 7.2.3.4 If(SAPI.SafetyBaseID == 0) Then BaseID:= SPI_SafetyBaseID_i Else BaseID:= SAPI.SafetyBaseID Endif If(SAPI.SafetyProviderID == 0) Then ProviderID:= SPI_SafetyProviderID_i Else ProviderID
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetySPDU_ID Table 36 - Presentation of the SPDU_ID SPDU_ID_1:= SafetyBaseID (octets 0…3) XOR SafetyProviderLevel_ID (octets 0…3) SPDU_ID_2:= SafetyBaseID (octets ... SafetyStructureSignature (octets 0…3) SPDU_ID_3:= SafetyBaseID (octets 8…11) XOR SafetyBaseID (octets 12…15) XOR SafetyProviderID (octets 0…3) In case of a mismatch between expected SPDU
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetySPDU_ID_3 . The following input values were chosen for the calculation: SafetyBaseID is the GUID "72962B91-FA75-4AE6-8D28-B404DC7DAF63", SafetyProviderID has the value 0xE0EA6B40, SafetyStructureSignature
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetySafetyBaseID and SafetyProviderID The pair of SafetyProviderID and SafetyBaseID is used by the SafetyConsumer to check the authenticity of the ResponseSPDU . SafetyProviderID and SafetyBaseID are usually assigned during engineering ... SafetyProviderIDs will reach its limits when the system becomes large, this document uses the SafetyBaseID for cases where guaranteeing unique SafetyProviderIDs is not possible. A SafetyBaseID is a universal unique
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety9.5 Safety manualresponsibility of the either the vendor or the integrator, or both. 4 SafetyBaseID / SafetyProviderID Information on how the SafetyBaseID and SafetyProviderID are generated and assigned. See 9.1.1 5 Commissioning Either
-
OPC-10000-15 – OPC Unified Architecture - Part 15: SafetyProvision of SafetyProviderDelay 8.2 Safety function response time part of communication RQ9.1 Storage of SafetyBaseID and SafetyProviderID 9.1.1 SafetyBaseID and SafetyProviderID RQ9.2a (Option 1) Use stored MNR after restart