Search
14 result(s) for Running
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsTrue Halted HasCause True Reset HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType ReadyToRunning ToState True Running FromState True Ready HasCause True Start HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType RunningToHalted ToState True ... Halted FromState True Running HasCause True Halt HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType RunningToReady ToState True Ready FromState True Running HasEffect True ProgramTransitionEventType HasEffect True AuditProgramTransitionEventType RunningToSuspended ToState True Running
-
OPC-10000-10 – OPC Unified Architecture - Part 10: ProgramsA.2.6.2 DomainDownloadTypeType . This definition identifies the StateTypes that compose the substates for the Program's Running StateType . Table A.3 - TransferStateMachineType Attribute Value Includes all attributes specified for the FiniteStateMachineType BrowseName TransferStateMachineType ... with the Transfer State Machine Type. All of these states are substates of the Running state of the base ProgramStateMachineType . The Opening state is the preparation state for the domain
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job Control6.2.1.1 Overviewstarted). When the job order starts to be executed, it switches its state to Running . Clients may interrupt a running job order by calling the Pause Method . The system ... system may automatically continue. In both cases, the state switches back to Running . A job order may be aborted by calling the Abort Method . This can be done while
-
OPC-10031-4 – OPC UA for ISA-95 - Part 4: Job Control6.2.1.8 Resume Methodsuccessful execution of the method, job order in the JobOrderList shall be in state Running . The signature of this Method is specified below. Table 25 and Table 26 specify
-
OPC-30020 – MDIS OPC UA Companion SpecificationReferences Node Class BrowseName DataType TypeDefinition Other Subtype of the MDISBaseObjectType 0:HasComponent Variable Running 0:Boolean 0:BaseDataVariableType M, RO 0:HasComponent Variable Operation MotorOperationEnum 0:BaseDataVariableType ... HasComponent Method SetOperation See 6.11.6 O ConformanceUnits MDIS Motor Base Running - Feedback from the motor if it is running (or not). If the motor is running it returns True. Operation
-
OPC-30020 – MDIS OPC UA Companion Specification6.11.5 Motor Stop Methodinvoked and the operation model is not Manual. If the motor is not Running this command is ignored. Comments The Stop Method commands the Motor to stop. Table 80 specifies
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.3.5 StateMachines Overviewstate that will be the starting point for the Cleared parent state. The Running State commonly will use the Resetting State as the initial state, but not all instance ... Running State sub-state model will include Resetting , so no initial state is defined for the Running State . The proposed valid initial States for this model are the Idle
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackMLHasComponent Object Stopped StateType HasComponent Object Stopping StateType HasComponent Object Clearing StateType HasComponent Object Running StateType HasComponent Object ExecuteState PackMLExecuteStateMachineType Mandatory HasComponent Object StoppingToStopped TransitionType HasComponent Object ClearingToStopped TransitionType HasComponent ... present in the ABORTED state. The value of this StateType is 1. Running - the State that allows the ExecuteState machine to become active, enabling sub-states provided by this StateMachine
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.1.5.1 OverviewHasComponent Object Clearing StateType 0:HasComponent Object ClearingToStopped TransitionType 0:HasComponent Object Running StateType 0:HasComponent Object RunningStateMachine RunningStateMachineType O 0:HasComponent Object RunningToAborting TransitionType 0:HasComponent Object RunningToStopping TransitionType ... faults that may have occurred when Aborting that are present in the Aborted state. Running is the state when the ActiveProgram , Function or FunctionalUnit is currently running/executing. RunningStateMachine
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.14.1 OverviewHasComponent Variable LastTransitionReason 0:Int16 0:MultiStateValueDiscreteType M 0:HasComponent Object Running 0:InitialStateType 0:HasComponent Object Stopping 0:StateType 0:HasComponent Object RunningToStopping 0:TransitionType Inherited from FiniteStateMachineType ... ExecutingSubstateMachineType are described in Table 71. Table 71 - ExecutingSubstateMachineType State Descriptions StateName Description Running The system is available, but cannot started because a preparation is needed Stopping The system
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementHasComponent Variable 0:LastTransition 0:LocalizedText 0:FiniteTransitionVariableType O, RO 0:HasComponent Object Running 0:StateType None 0:HasComponent Object RunningToAborted 0:TransitionType None 0:HasComponent Object RunningToEnded 0:TransitionType ... element in production after it was in the interrupted state. Running indicates that the operation of or on an element in production has been started or re-started
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementInterruptedToAborted 0:TransitionType None 0:HasComponent Object InterruptedToRunning 0:TransitionType None 0:HasComponent Object Running 0:StateType None 0:HasComponent Object RunningToAborted 0:TransitionType None 0:HasComponent Object RunningToEnded ... ProductionProgramType and ProductionPartType instances associated with it shall not remain in the state Running . Ended is reached when the job has finished all its runs, so the value of RunsCompleted
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job ManagementInterruptedToAborted 0:TransitionType None 0:HasComponent Object InterruptedToRunning 0:TransitionType None 0:HasComponent Object Running 0:StateType None 0:HasComponent Object RunningToAborted 0:TransitionType None 0:HasComponent Object RunningToEnded ... part does not have to be mounted inside the machine while in this state. Running indicates that the processing of the part within the machine has been started
-
OPC-40569-1 – OPC UA for Mining - Application and Use Cases - Part 1: Longwall Operation4.2.4 Use Case ConveyingShearer cyclically reads the State of the AFC. If the AFC's State is RUNNING , the Shearer reads the Load -Variable from the AFC. If the AFC's Load exceeds