OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub5.4.5.3 Key acquisition handshakespush fails, the affected PubSub components like WriterGroup or DataSetReader stay in the PreOperational state. If the updates fail and the PubSub components do not have up to date
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelleast one ConnectionEndpoint established at this FunctionalEntity has its Status set to PreOperational , the CommHealth CommPreOperational bit shall be set. For the definition of the CommHealthOptionSet
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model10.9 CommHealthOptionSetInitial . CommPreOperational 1 At least one of the ConnectionEndpoints has its Status set to PreOperational . CommError 2 At least one of the ConnectionEndpoints has its Status set to Error . Bits
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.1 Basic operationBasic operation After power-up the system goes into a Preoperational state. It is assumed that the vision system loads a configuration which is present on the system and marked
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.2 Resetting the systemrevert the vision system into its initial state after power-up, i.e., state Preoperational . The vision system may decide this due to internal conditions, or by calling the Reset method ... Initialized state - and the intent of calling the Reset method is to return to Preoperational state in order to call a different SelectMode method to change the mode of operation
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.3 Halting the systemHalted state by a call to the Reset method, transitioning to the Preoperational state. The vision system may decide to enter Halted state due to internal conditions or by calling
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.2.4 Error handlingcall to the Halt or Reset method, transitioning to states Halted and Preoperational respectively. The condition(s) causing the Error state do not necessarily have to be resolved for this ... triggered. By an internal decision of the system to transition into the Halted or Preoperational states. As these states do not constitute normal productive operation of the system, the condition
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.1 Introductionstates. Table 82 - VisionStateMachineType States BrowseName References Target BrowseName Value Target TypeDefinition Notes Preoperational HasProperty StateNumber 1 PropertyType -- FromTransition HaltedToPreoperational TransitionType -- FromTransition HaltedToPreoperationalAuto TransitionType -- FromTransition ErrorToPreoperationalAuto TransitionType -- FromTransition ErrorToPreoperational TransitionType ... will be detailed in the following subsections. Table 83 - VisionStateMachineType State Descriptions StateName Description Preoperational This is the initial state of the system after power-up and the state after
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.3 Halted Stateserver shall still be running to allow for a transition to state Preoperational. This state can be reached from any other state either by an automatic transition or by calling ... Halt method in this state will not have an effect. From this state, only Preoperational state can be reached, either by an automatic transition or by calling the Reset method
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.6.4 Error Statebased on the result of the error resolution into any other state, or into Preoperational state by a Reset method call or into Halted state by a Halt method call
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.2.8.2 Reset methodReset method This method commands the system to return to the Preoperational state where it has not parameterization for carrying out jobs (single or continuous), e.g. to reset the state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.1 Introductionconforming to this specification. This SubStateMachine is typically entered by a transition from state Preoperational to its internal state Initialized , either an automatic transition or caused by the SelectModeAutomatic method
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.2.1 IntroductionIntroduction The AutomaticMode state machine is entered from state Preoperational of the VisionStateMachineType either by an automatic operation or by the SelectModeAutomatic method. A call to SelectModeAutomatic causes transition
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementSubStateMachine of the Operational state can be entered in two different ways: From the Preoperational state of the parent state machine through an automatic transition or a transition triggered ... ways; for clarity, all other transitions have been left out. The transitions from the Preoperational state are shown as solid lines as they are actually modelled in the type definition
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.2 Initialized Statewhen the superior VisionStateMachine enters the Operational state either by an automatic transition from Preoperational or by a SelectModeAutomatic method call. If an error is dectected which suspends normal operation ... left in the following ways: Into Ready state by a PrepareRecipe method call. Into Preoperational state of the VisionStateMachine by a Reset method call. Into Halted state of the VisionStateMachine
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.3 Ready StateStartContinuous method call. Into the Initialized state by an UnprepareRecipe method call. Into the Preoperational state of the VisionStateMachine by a Reset method call. Into the Halted state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.4 SingleExecution Statestate by the methods Stop and Abort , see Section 8.3.2.4 for details. Into the Preoperational state of the VisionStateMachine by a Reset method call. Into the Halted state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.5.5 ContinuousExecution Statestate by Stop and Abort method calls, see Section 8.3.2.4 for details. Into the Preoperational state of the VisionStateMachineType by a Reset method call. Into the Halted state
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result management8.3.9 Adding an operation modebinds the SelectModeVendor method as additional HasCause to the method-triggered transition from the Preoperational state to the Operational state, i.e., T141 in Table 84 (according ... introduce a new transition, so the existing transition ). contains direct transitions from the Preoperational state into the desired starting state of the VendorModeStateMachine , typically an automatic one and one triggered
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementB.1.5.1 Types of recipe managementsystem that is configured outside the scope of this specification, starts automatically through states Preoperational and Initialized into Ready . It will immediately react to Start method, ignoring a possible recipe ... recipe system : a system that can hold a single recipe; it may start through Preoperational into Initialized , then wait for a call to the AddRecipe method and immediately prepare this
-
OPC-40100-1 – OPC UA for Machine Vision - Part 1: Control, configuration management, recipe management, result managementclient to actually force a return to the Initialized state is by going through Preoperational state via a reset. It must be prepared however that the vision system may fall