Search
4 result(s) for OperationOn
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)7.5.2 OperationOn MethodOperationOn Method The Method OperationOn turns the filter system machine on. It should only be available on the filter system if the filter units are considered components of the filter ... system and do not have their own OperationOn and OperationOff methods. The method changes the state of MachineryItemState. The signature of this Method is specified below. Table 26 specifies
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)7.5.3 OperationOff MethodOperationOff Method The Method OperationOff turns the filter system machine off. As with the OperationOn method, this method should be present under the FilterSystemType if and only if the filter
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)7.6.5 OperationOn MethodOperationOn Method The Method OperationOn turns the machine on. It should only be available on the filter unit if the filter unit is considered a machine, rather than a component ... machine. If the filter unit is only a component of a larger machine, the OperationOn Method should be present on the filter system . The method changes the state of MachineryItemState
-
OPC-40740 – OPC UA for Process Air Extraction and Filtration Systems (PAEFS)7.6.6 OperationOff MethodOperationOff Method The Method OperationOff turns the machine off. As with the OperationOn Method , this method should be present under the filter unit if and only if the filter unit