OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.2.4.3.9.2 PubSubcommunication configuration exceeds capabilities ( PublisherCapabilities , SubscriberCapabilities or ComponentCapabilities ) of the AutomationComponent , FunctionalEntities , InputData or OutputData , or if communication configuration cannot be applied, Bad_ConfigurationError shall be set in the Result
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelSubscriberCapabilities is referenced from a FunctionalEntity (see 6.4.2 ) or InputData (see 6.4.4 ), a preconfigured StandaloneSubscribedDataSet shall only reference InputVariables from the FunctionalEntity and its sub- FunctionalEntities . If the SubscriberCapabilities
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.1 Overviewfunctionality in an OPC UA FX Information Model . A FunctionalEntity can provide InputData , OutputData , ConfigurationData , diagnostic information and Methods for manipulating or sharing the data. It is expected that other
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelHasComponent Method 3:Verify Defined in 6.4.3 O 0:HasComponent Object 3:InputData 3:InputsFolderType O 0:HasComponent Object 3:OutputData 3:OutputsFolderType O 0:HasComponent Object 3:ConfigurationData ... will define subtypes of FunctionalEntityType . Subtypes will define additional Variables that would exist in InputData , OutputData and ConfigurationData . The subtypes might also add Objects and Methods or define nested FunctionalEntityType
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Model6.4.4 InputsFolderTypeInputsFolder may be empty. The optional SubscriberCapabilities shall only be present on InputData of the FunctionalEntity . It provides the Subscriber capabilities associated with the InputData and describes additional restrictions ... SubscriberCapabilities defined in the FunctionalEntity or AutomationComponent . The restrictions for InputData only apply if the Connection is established with Variables referenced in InputData or any subfolders. If an entry
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelexamples of ControlGroups, see Annex D.3 . The FunctionalEntity may provide Variables in its InputData , OutputData and ConfigurationData Folders . A ControlGroup may include any combination of the input, output, and configuration ... Variables from the FunctionalEntity . A FunctionalEntity may provide information in InputData , OutputData and ConfigurationData that are not part of any ControlGroup . ControlGroups are primarily used for locking, but they
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelcommunication model connected to the ConnectionEndpoint . All referenced Variables shall be in the InputData of the FunctionalEntity related to the ConnectionEndpoint or a SubFunctionalEntity of the FunctionalEntity. The referenced Variables ... subset of the Variables referenced by InputData . The optional OutputVariables reference Variables that are to be reported by the communication model connected to the ConnectionEndpoint . All referenced Variables shall
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelB.3.2.1 Extending an existing typeaspect of a FunctionalEntity , so the IFunctionalEntity Interface was added to the model. The InputData , OutputData and ConfigurationData folders provided by the Interface were updated to include references
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelFunctionalEntity as well as an instance of FxAssetType . The FunctionalEntity organizes in its InputData , OutputData , and ConfigurationData Variables, which are components of the MyModelInstance (derived from the MyCompanionSpecType). Figure
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modelwhich includes a SafetyProvider . The FunctionalEntity contains safety and non-safety Variables in its InputData and OutputData . Figure C.2 - FunctionalEntity with safety data From a FunctionalEntity's perspective, the safety ... Variables CtrARequest and CtrAResponse are organised within the InputData and OutputData . In addition, these Variables are referenced by HasComponent References from the SafetyPDUs Object of the SafetyProvider (see also
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelD.3.6.1 OverviewD.3.6.1 Overview InputData and OutputData can be modelled in various ways. The following clauses show examples of their usage. Figure D.20 illustrates the subtype of FunctionalEntityType that is used ... other devices as needed. Figure D.20 - Example FunctionalEntity Type The following examples illustrate how InputData and OutputData can be joined with DataSets . Consider, for example, an analogue input module with
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information Modeldata. The interface is represented by the ListToRestrict and ListOfRelated References . By this, the InputData , OutputData , ConfigurationData, and all provided Methods belonging to the interface can be easily determined
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineering8.3.2 Descriptor Importcomplete the Information Model for Controller B, e.g., defining the complementary FunctionalEntity, InputData and OutputData information for Controller B. The exchange of a Descriptor between Controls Engineers is further described
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringinformation of the exported Descriptor for the configuration of another AutomationComponent , e.g., for configuring InputData from the OutputData information in a Controller-to-Controller communication scenario. In both cases
-
OPC-10000-83 – OPC Unified Architecture - Part 83: UAFX OfflineEngineeringSubscriberCapabilities structure exists in the FunctionalEntity sub-model at three levels: AutomationComponent , FunctionalEntity and InputData and OutputData levels. In Figure F.8 , a FunctionalEntity "FillControl" is created that represents ... digital output variable, "ValveOpenClose". Both Variables are organized as InputData and OutputData of the FunctionalEntity, "FillControl".The "FillLevel" signal is coming from a FunctionalEntity
-
OPC-10000-84 – OPC Unified Architecture - Part 84: UAFX Profiles5.2.5 UAFX FunctionalEntitythat is referenced from this FunctionalEntity ), supports at least one of the UAFX IFunctionalEntity InputData or UAFX IFunctionalEntity OutputData ConformanceUnits . Server UAFX IFunctionalEntity InputData Supports InputData of the IFunctionalEntity Interface ... This includes supporting all required types Server UAFX FunctionalEntity SubFunctionalEntity Supports the HasSubFunctionalEntity Reference . InputData Server UAFX InputsFolder SubscriberCapabilities Base Supports SubscriberCapabilities of the InputsFolderType . Server UAFX InputsFolder Hierarchy Supports