Search
21 result(s) for InputArguments
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.7.1 Method NodeClasssubscribe to it to determine when the structure of a Node has changed. InputArguments O Argument[] The InputArguments Property is used to specify the arguments that shall be used ... Client accessed it. Properties may be defined for Methods using HasProperty References . The Properties InputArguments and OutputArguments specify the input arguments and output arguments of the Method . Both contain
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space ModelNodeClass. Optional input arguments shall always follow any non-optional input arguments in the InputArguments array. For example, if a method has 3 arguments with 1 being optional then
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.4 OptionalPlaceholderdefinition with the OptionalPlaceholder only defines the BrowseName. An instance or subtype defines the InputArguments and OutputArguments . A subtype shall also change the ModellingRule to Optional or Mandatory . The Method
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model6.4.4.4.5 MandatoryPlaceholderdefinition with the MandatoryPlaceholder only defines the BrowseName. An instance or subtype defines the InputArguments and OutputArguments . A subtype shall also change the ModellingRule to Mandatory . The Method is mandatory
-
OPC-10000-4 – OPC Unified Architecture - Part 4: Services5.12.2.2 ParametersNode that is the target of a HasComponent from the Node defined by objectId . inputArguments [] BaseDataType List of input argument values. An empty list indicates that there are no input ... list matches the size and order of the input arguments defined by the input InputArguments Property of the Method . The name, a description and the data type of each argument
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information Model6.4.27 AuditUpdateMethodEventTypeHasProperty Variable MethodId NodeId PropertyType Mandatory HasProperty Variable StatusCodeId StatusCode PropertyType Optional HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory HasProperty Variable OutputArguments BaseDataType[] PropertyType Optional Conformance Units Auditing Method Auditing Method ... Property is optional for backward compatibility and required by Profiles starting with version 1.05. InputArguments provide the values of the input arguments passed to the Method . This parameter
-
OPC-10000-5 – OPC Unified Architecture - Part 5: Information ModelHasProperty Variable MethodId ExpandedNodeId PropertyType Mandatory HasProperty Variable StatusCodeId StatusCode PropertyType Mandatory HasProperty Variable InputArguments BaseDataType[] PropertyType Mandatory HasProperty Variable OutputArguments BaseDataType[] PropertyType Mandatory ConformanceUnits Base Info Client Events This ... ExpandedNodeId serverIndex . StatusCodeId identifies the overall status returned by the Method Call . InputArguments identifies the input arguments for the method. This parameter can be null if no input arguments were
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.1 Overviewcause the associated state transition. The Method instances referenced by the ProgramStateMachineType identify the InputArguments and OutputArguments required for the Method calls to Program Invocations of that ProgramStateMachineType . Table ... ProgramStateMachineType causes BrowseName References Target BrowseName Value Target TypeDefinition NOTES Causes Start HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Suspend HasProperty InputArguments PropertyType Optional HasProperty OutputArguments PropertyType Optional Resume
-
OPC-10000-10 – OPC Unified Architecture - Part 10: Programs5.2.4.3 Standard propertiesStandard properties Methods can reference a set of InputArguments. For each ProgramStateMachineType , a set of InputArguments may be defined for the supported Program Control Methods . The data passed
-
OPC-10000-12 – OPC Unified Architecture - Part 12: Discovery and Global Servicesraised when the UpdateCertificate Method is called. If a PrivateKey was one of the InputArguments then that argument is set to NULL before generating this Event . Its representation
-
OPC-10100-1 – OPC UA for WoT Connectivity - Part 1: API Definition6.3.9 WoT Actions Mappingcomponent of an Object that implements IWoTAssetType (see 6.3.8 ). The Method and its InputArguments and OutputArguments Properties are mapped to a TD as shown in Table 15 . Table
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.3 SetMachSpeed Methodspecifies the AddressSpace representation for the SetMachSpeed Method . SetMachSpeed includes an array of InputArguments , where the input argument details are provided in Table 26 . Table 28 - SetMachSpeed Method AddressSpace Definition ... Attribute Value BrowseName SetMachSpeed References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.4 SetProduct Methodspecifies the AddressSpace representation for the SetProduct Method . SetProduct includes an array of InputArguments , where the input argument details are provided in Table 29 . Table 31 - SetProduct Method AddressSpace Definition ... Attribute Value BrowseName SetProduct References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.10 Start Methodspecifies the AddressSpace representation for the Start Method . Start includes an array of InputArguments , where the input argument details are provided in Table 42 . Table 44 - Start Method AddressSpace Definition ... Attribute Value BrowseName Start References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.15 RemoteCommand Methodspecifies the AddressSpace representation for the RemoteCommand Method . RemoteCommand includes an array of InputArguments , where the input argument details are provided in Table 53 . Table 55 - RemoteCommand Method AddressSpace Definition ... Attribute Value BrowseName RemoteCommand References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.16 SetInterlock Methodspecifies the AddressSpace representation for the SetInterlock Method . SetInterlock includes an array of InputArguments , where the input argument details are provided in Table 56 . Table 58 - SetInterlock Method AddressSpace Definition ... Attribute Value BrowseName SetInterlock References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-30050 – OPC UA for PackML - Common Object Model: PackML6.7.17 SetParameter Methodspecifies the AddressSpace representation for the SetParameter Method . SetParameter includes an array of InputArguments , where the input argument details are provided in Table 59 . Table 61 - SetParameter Method AddressSpace Definition ... Attribute Value BrowseName SetParameter References NodeClass BrowseName DataType TypeDefinition ModellingRule HasProperty Variable InputArguments Argument[] PropertyType Mandatory
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.25.1 TriggerMain Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 55 . Signature
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.1 LoadConfigurationFileMain Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 66 . Signature
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.31.2 SaveConfigurationFilestored in ConfigurationFile. The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 67 . Signature
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems7.49.1 DrainTestMain Control System . The signature of this Method is specified below. There are no InputArguments or OutputArguments defined. Its formal representation in the AddressSpace is defined in Table 105 . Signature