OPC-30141 – OPC UA for PROFIenergy8.2.2 EnergyMeasurementTypeEnergyMeasurementType The EnergyMeasurementType contains References to MeasurementValueType Object s. Table 20 - EnergyMeasurementType Definition Attribute Value BrowseName EnergyMeasurementType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of the BaseObjectType ... PESAP is not part of the Information Model , the RepresentedBy Reference in the EnergyMeasurementType Object is omitted. Mapping to PROFIenergy properties: BrowseName PE Service PE Service Data Response Field PeObjectNumber
-
OPC-34100 – OPC UA for Energy Consumption ManagementEnergyMeasurementType ObjectType Definition The EnergyMeasurementType provides various energy measurement values measured at the same point in a system and is formally defined in Table 16 . Table 16 - EnergyMeasurementType Definition Attribute ... Value BrowseName EnergyMeasurementType IsAbstract False References Node Class BrowseName DataType TypeDefinition Other Subtype of the 0:BaseObjectType 0:HasProperty Variable ApplicationTag 0:String 0:PropertyType M, RW 0:HasComponent Variable
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationSerializationScope shown in Figure 5 comprises all MeasurementValueType Variables which are components of the EnergyMeasurementType Objects organized in the "EnergyManagement" Folder Object . The SerializationScope is configured to exclude
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serializationexclude the metadata Properties of the Objects and Variables reachable from the SerializationStartNode . The EnergyMeasurementType Object has a mandatory PeObjectNumber Property which is not part of the SerializationScope since
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationDataSet . As shown in A.4 , the SerializationConfiguration excludes the metadata Properties attached to the EnergyMeasurementType Objects as well as to the MeasurementValueType Variables . The metadata can be conveyed
-
OPC-30141 – OPC UA for PROFIenergystructural organization of the energy related functionality. Devices offering Energy Measurement functionality provide EnergyMeasurementType Object s. Each EnergyMeasurementType Object contains the measurement values belonging to a specific Metering Point ... application model. HasEnergyMeasurement References connect the functional parts of the model with related EnergyMeasurementType Object s providing Energy Measurement values. HasEnergyStandbyManagement References connect the functional parts of the model offering
-
OPC-30141 – OPC UA for PROFIenergyPESAP Object . Figure 10 shows that all PE Energy Management Object instances ( EnergyStandbyManagementType Object , EnergyMeasurementType Object s and EnergyDevicePowerOffType Object ) are connected to a related PESAP Object using Represents References
-
OPC-30141 – OPC UA for PROFIenergy8.2.1 OverviewObject s provide access to the Energy Measurement values. For each Metering Point one EnergyMeasurementType Object shall exist
-
OPC-30141 – OPC UA for PROFIenergyInterfaces for EnergyProfiles EnergyMeasurementType Object s should support Interfaces for standardized energy data profiles, so called EnergyProfiles . The supported measurement values demanded by an energy data profile are specified ... Interfaces applied to instances of the EnergyMeasurementType . Table 21 shows the definitions of the Interfaces for the standardized energy data profiles. The EnergyProfiles represent standard Energy Measurement use cases
-
OPC-30141 – OPC UA for PROFIenergymandatory for PROFIenergy class 2 and class 3 and shall point to the EnergyMeasurementType Object representing the Energy Measurement functionality. One optional Represents Reference with the BrowseName "EnergyPowerOff
-
OPC-30141 – OPC UA for PROFIenergycounter is reset. A reset can be performed using the ResetEnergyCounter Method of the EnergyMeasurementType Object which contains the MeasurementValueType Variable . After the start of the device the ValueBeforeReset Variable ... shall use the same EngineeringUnits as defined in the Interface implemented by the containing EnergyMeasurementType Object . When reading the value of the MeasurementValueType Variable the status code shall
-
OPC-30141 – OPC UA for PROFIenergyObject offering Energy Measurement functionality. The TargetNode shall be an Object of the EnergyMeasurementType . The semantic of this ReferenceType is to connect the EnergyMeasurementType Object s with the functional part
-
OPC-30141 – OPC UA for PROFIenergy12.1 Conformance UnitsPROFIenergy Common Application Profile). Server PNEM EnergyProfile E0 IEnergyProfileE0 Interface is supported by EnergyMeasurementType Object instances. Server PNEM EnergyProfile E1 IEnergyProfileE1 Interface is supported by EnergyMeasurementType Object instances. Server PNEM ... EnergyProfile E2 IEnergyProfileE2 Interface is supported by EnergyMeasurementType Object instances. Server PNEM EnergyProfile E3 IEnergyProfileE3 Interface is supported by EnergyMeasurementType Object instances. Server PNEM EnergyProfile D0 IEnergyProfileD0 Interface is supported
-
OPC-34100 – OPC UA for Energy Consumption Management6.2.1 Base Conceptsvalues or aggregated values (counters), the information model enables to create Objects of ObjectType EnergyMeasurementType with potentially several measurements measured at the same point in a system represented by Variables ... measurement like the engineering unit. In Figure 8 , an overview of the EnergyMeasurementType and the EnergyMeasurementValueType is given. They are formally defined in 7.1.1 and 8.1 . Figure 8 - Overview EnergyMeasurementType
-
OPC-34100 – OPC UA for Energy Consumption Management6.2.2.1 Overviewunique identification that is used as BrowseName for instances of the EnergyMeasurementType . Those BrowseNames are also used for the interfaces (see 6.2.3 ). The Description (in English) may be used ... Description Attribute for those Nodes . For all instances of EnergyMeasurementType using the BrowseName as defined in the table, the EngineeringUnits shall be used for the 0: EngineeringUnits Property, the DataType
-
OPC-40001-4 – OPC UA for Machinery - Part 4: Energy ManagementThis specification defines a recommended mapping of resources to Interfaces , Objects of the 3: EnergyMeasurementType should implement. In this version of the specification, not all resources defined