28 result(s) for EURange
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model5.8.5.1 Overviewmeta data to fields of the Structured DataType , like providing the EngineeringUnits or EURange . In order to restrict the usage for each field of a Structured DataType , the following
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.2.2 BaseAnalogTypeHasProperty Variable InstrumentRange Range PropertyType Optional HasProperty Variable InstrumentNumberRange NumberRange PropertyType Optional HasProperty Variable EURange Range PropertyType Optional HasProperty Variable EUNumberRange NumberRange PropertyType Optional HasProperty Variable EngineeringUnits EUInformation PropertyType Optional ... with the equivalent value for legacy reasons. The NumberRange DataType is specified in 5.6.3 . EURange defines the value range likely to be obtained in normal operation. It is intended
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access5.3.4.1 GeneralHasSubtype VariableType NDimensionArrayItemType Defined in 5.3.4.6 HasProperty Variable InstrumentRange Range PropertyType Optional HasProperty Variable EURange Range PropertyType Mandatory HasProperty Variable EngineeringUnits EUInformation PropertyType Mandatory HasProperty Variable Title LocalizedText PropertyType Mandatory ... Units Data Access ArrayItem2Type InstrumentRange defines the range of the Value of the ArrayItem. EURange defines the value range of the ArrayItem likely to be obtained in normal operation
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Access7.2 PercentDeadbandthis type of deadband the deadbandValue is defined as the percentage of the EURange . That is, it applies only to AnalogItems with an EURange Property that defines the typical value ... absolute value of (last cached value - current value) > (deadbandValue/100.0) * ((high-low) of EURange))) The range of the deadbandValue is from 0,0 to 100,0 per cent. Specifying
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data Accessbetween 0.0 and 100.0 or a PercentDeadband is not supported, since an EURange is not configured. Bad_WaitingForInitialData Defined in OPC 10000-4 Table 62 - Operation level result codes
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.3.1.3 ItemVariable of AnalogItemType in the COM UA Wrapper. The AnalogItemType has the following Properties: EURange : The values of the High EU and Low EU properties of the DA Item ... assigned to the EURange Property EngineeringUnits : The value of the Engineering Unit property of the DA Item are assigned to the EngineeringUnits Property . InstrumentRange: The values of the High
-
OPC-10000-8 – OPC Unified Architecture - Part 8: Data AccessA.4.2.3 Variable NodesServer: Analog(1) : if the node in the OPC UA Server references a EURange property node, then it is assigned the Analog EU Type. Enumerated(2) : if the node ... Property ID: 102) : if the node in the OPC UA Server references a EURange property node, then the 'High' value of the property node is assigned to this property
-
OPC-10000-11 – OPC Unified Architecture - Part 11: Historical AccessPERCENT_OF_EU_RANGE 3 ExceptionDeviation is a percentage of EURange ( EURange is defined in OPC 10000-8 ). UNKNOWN 4 ExceptionDeviation type is Unknown or not specified. Its representation
-
OPC-10000-14 – OPC Unified Architecture - Part 14: PubSub9.1.12.2 Supported configuration propertiesdefault value for the property. Description of the Variable provides additional information. Properties like EURange or EngineeringUnits can be used to provide value ranges and units. The configuration property descriptions
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 Serverbase required aspect of the MDISInstrumentObjectType . This includes the ProcessVariable . The ProcessVariable includes EURange and EngineeringUnits Server MDIS Instrument Limits Supports at least one of the following limit flags: HHlimit
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information ModelPres_Value and Max_Pres_Value are mapped the OPC UA Properties EngineeringUnits and EURange of the OPC UA VariableType AnalogItemType . Figure 7 shows an example how groups of BACnet
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.4.3.1 Variable Present_ValueVariableType AnalogItemType is defined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property and the mapping ... Value Attribute of the Variable . Min_Pres_Value represented by Low part of EURange Property of the Variable . If the optional BACnet property Min_Pres_Value is not present
-
OPC-30030 – OPC UA for BACnet - BACnet: OPC UA Information Model7.18.3.1 Variable Present_ValueVariableType AnalogItemType is defined in OPC 10000-8 . It defines the OPC UA Properties EURange , EngineeringUnits and InstrumentRange . The following list provides the BACnet property and the mapping ... represented by Value Attribute of the Variable . Minimum_Output represented by Low part of EURange Property of the Variable . If the optional BACnet property Minimum_Output is not present
-
OPC-30060 – OPC UA for Tobacco Machine Communication8.44.1 Overviewrate is referred to the either product or time, as indicated by the EURange property. For example, SamplingRate equal to 100 ms means that the value is measured and collected ... value is measured and collected for aggregation every 100 rods of product. The EURange property of the SamplingRate is read only and defines both the unit of measure
-
OPC-30060 – OPC UA for Tobacco Machine Communicationrate is referred to the either product or time, as indicated by the EURange property. For example, SamplingRate equal to 100 ms means that the value is measured and collected ... value is measured and collected for aggregation every 100 rods of product. The EURange property of the SamplingRate is read only and defines both the unit of measure
-
OPC-30090 – OPC UA for Field Device Tool (FDT) - Part <mm>: <Part Name>9.1 FdtParameterPropertyType O 0:HasProperty Variable ApplicationId ApplicationIdEnumeration 0:PropertyType O 0:HasProperty Variable 0:EURange 0:Range 0:PropertyType O 0:HasProperty Variable 0:EngineeringUnits 0:EUInformation 0:PropertyType ... FdtParameter is an Enumeration DataType, then EnumStrings are used according to OPC 10000-3. EURange and EngineeringUnits are used as defined in OPC 10000-8 for the AnalogueItem variable type
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.1.1 SetApplicationTag MethodLastParameterChange timestamp Variable shall be changed by the Server. This includes the EngineeringUnits and EURange Properties of Process Value Variables and any change of configuration data provided
-
OPC-30142 – OPC UA for PROFINET Remote IOconversion values and similar, the EngineeringUnits Property shall not be provided. The optional EURange Property of the DataValue Variable shall be provided only if the EngineeringUnits property is provided
-
OPC-30142 – OPC UA for PROFINET Remote IOconversion values and similar, the EngineeringUnits Property shall not be provided. The optional EURange Property of the DataValue Variable shall be provided only if the EngineeringUnits property is provided
-
OPC-30144 – OPC UA for PROFINET GSD Generic Model - Part 30144: PROFINET GSD Generic Model7.1.1 SetApplicationTag MethodTable 64 ) or by the BMP Unit (see Table 65 ) for BMPs. The EURange Property of the 0:AnalogUnitRangeType Variable shall be provided for Data Objects with associated engineering unit ... Variable EngineeringUnits 0:EUInformation 0:PropertyType O, RO <EnumerationVariable> 0:HasProperty Variable EURange 0:Range 0:PropertyType O, RO <ArrayFolder> 0:HasProperty Variable EngineeringUnits 0:EUInformation
-
OPC-30145 – OPC UA for PROFINET Drives - Part 30145: UA CS for PROFINET Drivestemperature value provided by the Server . The Server might provide the optional InstrumentRange and EURange Properties of the 0:AnalogUnitType the TemperatureVariableType is derived from. The WarningThreshold Property contains
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valuesprovides the optional Properties 0: ValuePrecision and 0: InstrumentRange and the mandatory Properties 0: EURange and 0:EngineeringUnits and are used as defined in OPC 10000-8 . They provide information
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valuesmeta data about the process value. The 3: AnalogSignalVariableType already provides the mandatory 0: EURange , 0: EngineeringUnits and the optional 0: ValuePrecision , 0: InstrumentRange , 3: ActualValue , 3: SimulationValue ... dynamic, so that the client cannot calculate the percentage based on the 0: EURange of the 3:AnalogSignal Variable. As an example, the wear of a filter should be exposed
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process Valueshave the same Values as defined on the Variable it belongs to. The 0: EURange shall be the same, or further restricted by providing a smaller high or a higher ... settings of DeviationSensitivity (if provided) in case the configuration has changed (0: EURange or DeviationSensitivity ). If set to TRUE, the deviation Variables shall be automatically adjusted and writing the deviation
-
OPC-40001-2 – OPC UA for Machinery - Part 2: Process ValuesB.1 OverviewT001" AnalogSignal (M) 200 65 ValuePrecision (O) -2 (Rounded to next 100) - EURange (M) {-100.0, 250.0} {-20.0, 180.0} InstrumentRange (O) {-500.0, 350.0} {-200.0, 300.0} EngineeringUnits (M) Pa (Pascal ... SimulationValue (O) 100 20 SimulationState (O) FALSE FALSE Damping (O) - - PercentageValue (O) 60 1 - EURange(M) {0.0,100.0} - EngineeringUnits(M) pct (Percent) - LowLowLimit (O) 20 5 EngineeringUnits(M) Pa (Pascal
-
OPC-40010-1 – OPC UA for Robotics - Part 1: Vertical Integration7.3.2 AxisType definitionaxis and may have limits. If the axis has physical limits, the EURange property of the AnalogUnitType shall be provided. Variable ActualSpeed : The ActualSpeed variable provides the axis speed. Applicable ... speed limits of the axis shall be provided by the EURange property of the AnalogUnitType. Variable ActualAcceleration : The ActualAcceleration variable provides the axis acceleration. Applicable acceleration limits of the axis
-
OPC-40200 – OPC UA for Weighing TechnologyWeightItemType or a PrintableWeightItemType it is the unit of net, gross and tare. EURange is specified like the EURange of the 0:AnalogItemType in OPC 10000-8. If the DataType ... range of net, gross and tare. InstrumentRange is specified like the EURange of the 0:AnalogItemType
-
OPC-40503-1 – OPC UA for Metal Forming - Part 1: GeneralTable 16 . For each cycle, the selected positions will get the ActualValue , Setpoint , EURange , EngineeringUnits and corresponding CycleCount as a CyclicProcessValueType , defined in 7.2 . Figure 13 shows a hydraulic press