OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.1 RioPaAnalogInputChannelTypeHasComponent Variable SimulationValue RioPaAnalogValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaAnalogInputConfigDataType RioPaAnalogInputConfigVariableType M, RO 0:HasComponent Method SetMode O 0:HasComponent Method SetManualProcessValue O 0:HasComponent Method SetSimulation ... value used as Process Value if the SimulationEnabled Variable contains the Value True. The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.2.6 RioFaAnalogInputChannelTypeHasComponent Variable SignalValue 0:Double 0:BaseAnalogType O, RO 0:HasComponent Variable Config RioFaAnalogInputConfigDataType RioFaAnalogInputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the current analog Input ... obtained by reading the input signal through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.1 RioPaAnalogOutputChannelTypeHasComponent Variable SimulationValue RioPaAnalogValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaAnalogOutputConfigDataType RioPaAnalogOutputConfigVariableType M, RO 0:HasComponent Method SetMode O 0:HasComponent Method SetManualOutValue O 0:HasComponent Method SetSimulation ... value in place of the Process Value if the SimulationEnabled Variable contains True. The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.3.6 RioFaAnalogOutputChannelTypeHasComponent Variable SignalValueReadback 0:Double 0:BaseAnalogType O, RO 0:HasComponent Variable Config RioFaAnalogOutputConfigDataType RioFaAnalogOutputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the current analog Output ... contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.1 RioPaDigitalInputChannelTypeHasComponent Variable SimulationValue RioPaDigitalValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaDigitalInputConfigDataType RioPaDigitalInputConfigVariableType M, RO 0:HasComponent Method SetMode O 0:HasComponent Method SetManualProcessValue O 0:HasComponent Method SetSimulation ... value used as Process Value if the SimulationEnabled Variable contains the Value True. The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.4.6 RioFaDigitalInputChannelTypeHasComponent Variable SignalValue 0:Double 0:BaseAnalogType O, RO 0:HasComponent Variable Config RioFaDigitalInputConfigDataType RioFaDigitalInputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains the digital Input value ... obtained by reading the input signal through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.1 RioPaDigitalOutputChannelTypeHasComponent Variable SimulationValue RioPaDigitalValueDataType 0:BaseDataVariableType O, RO 0:HasComponent Variable Config RioPaDigitalOutputConfigDataType RioPaDigitalOutputConfigVariableType M, RO 0:HasComponent Method SetMode O 0:HasComponent Method SetManualOutValue O 0:HasComponent Method SetSimulation ... value in place of the Process Value if the SimulationEnabled Variable contains True. The Config Variable contains the configuration properties available for the RIO Channel . See the definition
-
OPC-30142 – OPC UA for PROFINET Remote IO7.2.5.6 RioFaDigitalOutputChannelTypeHasComponent Variable SignalValueReadback 0:Double 0:BaseAnalogType O, RO 0:HasComponent Variable Config RioFaDigitalOutputConfigDataType RioFaDigitalOutputConfigVariableType M, RO Conformance Units PNRIO Channel Objects The ProcessValue Variable contains a Controller's output ... contains the output signal read back through the signal coupling in the Transducer . The Config Variable contains the configuration properties available for the RIO Channel . See the definition