OPC-30142 – OPC UA for PROFINET Remote IOConnection of PROFINET Aspect and Functional Aspect Figure 11 - 2 analog RIOforPA channels Figure 11 shows the Channel model for analog Input according to RIOforPA to illustrate the relationship between ... connection of the PROFINET aspect and the functional aspect with two analog RIO Input Channels according to RIOforPA in the Information Model is shown in Figure 12 . Figure
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Groups The qualifiers in RIOforFA Channels are single bits transferred together in one or more bytes (see [ RIO FA ] sec. 7.2). Therefore, the Telegram contains an arbitrary number ... PROFINET aspect to their counterparts in the RIO aspect for analog RIO Output Channels according to RIOforFA. The qualifier Signal Object is connected to a RioBitFieldVariableType Variable containing
-
OPC-30142 – OPC UA for PROFINET Remote IOsupport an arbitrary subset of these properties. Each supported property applies to all represented channels of the RIO Channel Group . The Server may provide only one of the PaDigitalSubstituteValue , FaDigitalSubstituteValue ... Property contains the substitute values for the Process Value of the represented digital RIOforPA channels which shall be used if a failure is detected. The usage of the substitute value
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Groups The InputValues array Variable contains the Input Process Values of the Input Channels the RIO Channel Group Object represents. The InputValues Variable is linked to the associated PnIoTelegramType ... RioChannelNumber of the represented Input Channel s. The RioChannelNumbers of the Input Channels shall have the value range 0 to <size of InputValues array> minus 1. The OutputValues
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Groups The InputImageValues array Variable contains the Input Process Values of the Input Channels the RIO Channel Group Object represents. The InputImageValues Variable is linked to the associated PnIoTelegramType ... RepresentsSameEntityAs Reference . The OutputImageValues array Variable contains the Output Process Values of the Output Channels the RIO Channel Group Object represents. The OutputImageValues Variable is linked to the associated PnIoTelegramType
-
OPC-30142 – OPC UA for PROFINET Remote IOChannel Groups The InputImage array Variable contains the Input Process Values of the Input Channels the RIO Channel Group Object represents. The InputImage Variable is linked to the associated PnIoTelegramType ... RioChannelNumbers of the represented Input Channel s. The RioChannelNumbers of the Input Channels shall have the value range 0 to <size of InputImage array> minus 1. The OutputImage
-
OPC-30142 – OPC UA for PROFINET Remote IORioChannelNumber of the represented Input Channel s. The RioChannelNumbers of the Input Channels shall have the value range 0 to <number of Input Channels > minus 1. The OutputImage ... Reference . The bit numbers must be equal to the RioChannelNumber of the represented Output Channels minus the number of Input Channels . The RioChannelNumbers of the Output Channels shall have
-
OPC-40501-1 – OPC UA for Machine Tools - Part 1: Machine Monitoring and Job Management14.2.2.2 MachineTool Basic Server Profileaddress space functionality any MachineTool server shall at least provide. Concerning Stacklights and Channels , it is expected that a server models these elements if they are available on the machine ... Monitoring Basic - PowerOnDuration O MachineTool MachineTool Monitoring Machinery PowerOnDuration O MachineTool MachineTool Monitoring Basic - Channels M MachineTool MachineTool Production Basic M Machinery 3:Machinery Building Block Organization