OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.1 AirnetAirnet Piping and all Components between at least two distinct points, the inputs and outputs of the Airnet , in a Compressed Air System . Note 1 to entry: A Component
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.2 CASPartCompressed Air System . Note 1 to entry: CASParts defined in this specification are: Airnet , all Components , Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.4 Compressed Air SystemSystem System that generates compressed air, consists of Components and at least one Airnet , and is commonly equipped with one Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsUsually the Customer Distribution Point is located at one of the outlets of an Airnet . Note 2 to entry: The Customer Distribution Point provides Variables and/or Objects which describe
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems3.2.15 Requirements [of an Airnet]Requirements [of an Airnet] The actual requirements of an Airnet are not specified in this specification. The following examples of Requirements do not imply the actual requirements of an Airnet ... EXAMPLE 1 The Airnet pressure shall be within range. EXAMPLE 2 The dew point shall be within range. EXAMPLE 3 The volume flow rate shall be within range
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsSystem . All browsable Components shall be identifiable. This includes non-communicating Components (e.g. Airnet , receiver) as well as assets capable of communication (e.g. compressor
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems6.3 Airnet ExamplesAirnet Examples Figure 8 shows a simple model of an Airnet . The inlet of the Airnet is the sum of the inlets of compressors C1 and C2. The outlet ... Airnet is the Customer Distribution Point . All CASParts that are inside the red box are connected to the red Airnet and treated as such. The Main Control System
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsComponents Object , just like the CompressedAirSystem Object . For each DeviceClass connected to an Airnet , there is one ComponentGroup Object in the Components Object of that Airnet . Connected Components are referenced
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAirnetType ObjectType DefinitionThe AirnetType is the representation of an Airnet and provides both Objects for Quantities and FunctionalGroups . It is illustrated in Figure 19 and formally defined in Table ... optional Object Ambient provides Quantities for the ambient air conditions at an Airnet . Of the optional Variables of the FluidQuantitiesType only AbsolutePressure, DewPoint, RelativeHumidity, and Temperature are available. The optional
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsHasComponent Object 2:Identification 4:MachineryItemIdentificationType M The optional Property ActiveAirnet indicates which Airnet is currently using this Component . The Property shall only be instantiated if the Component is connected ... more than one Airnet . The optional Object Ambient provides Quantities for the ambient air conditions at a Component . Of the optional Variables of the FluidQuantitiesType only AbsolutePressure, DewPoint, RelativeHumidity
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsdefined in Table 56 . Such analyses may be performed on Compressed Air System or Airnet level. Table 56 - AnalysesType Definition Attribute Value BrowseName AnalysesType IsAbstract False References Node Class BrowseName
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAirnetConfigurationType ObjectType Definition The AirnetConfigurationType provides Variables for configuring the behavior of an Airnet and is formally defined in Table 62 . Table 62 - AirnetConfigurationType Definition Attribute Value BrowseName AirnetConfigurationType IsAbstract ... optional Variable OperatingModes provides manufacturer or system specific operating modes of an Airnet . When instantiating the AirnetConfigurationType, the manufacturer or system integrator shall add specific operating modes to the EnumStrings
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systemsdescribes whether the Main Function of a Component or the Requirements of an Airnet can be fulfilled. The states may be influenced by the events and condition instances ... describes whether the Main Function of a Component or the Requirements of an Airnet should be fulfilled. Some subtypes of this OperationalType define more specific states and provide a more
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAirnetOperationalType ObjectType Definition The AirnetOperationalType extends its supertype by Airnet specific Variables and is formally defined in Table 97 . Table 97 - AirnetOperationalType Definition Attribute Value BrowseName AirnetOperationalType IsAbstract False References ... HasComponent Variable OperatingState AirnetOperatingStateEnum 0:DataItemType O, RO Three KPIs were defined for an Airnet . Each of these KPIs is derived from ISO 11011 and is described below. The KPIs
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control Systems9.2.2.2 CAS Base Analyses Server FacetControl System that provides prefabricated or pre-parameterized analyses on Compressed Air System or Airnet level. Although both Conformance Units are listed as optional, at least one shall be implemented
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsMain Control System that provides parameterizable analyses on Compressed Air System or Airnet level and the possibility to store analysis reports in the AddressSpace. Table 165 - CAS Advanced Analyses Server
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsAdding or Removing a Component to/from an Airnet During the life of a Compressed Air System the manufacturer, integrator, or operator may wish to add or remove Components ... from one of the Airnets . This also includes moving a Component permanently from one Airnet to another. The OPC UA provided Services AddReferences and DeleteReferences can add or remove References
-
OPC-40250-1 – OPC UA for Compressed Air Systems - Part 1: Main Control SystemsTemporarily Switch a Component from one Airnet to Another Some Main Control Systems allow for Components to switch from one Airnet to another by operating a valve or a similar ... valve or a similar action switches one of these Components from one Airnet to another, the ActiveAirnet Property changes its Value Attribute to indicate which Airnet is currently using