18.2 Profiles18.2.1 Profile listThe following tables specify the facets available for Servers that implement the OPC 40082-6 Information Model companion specification.
NOTE: The names of the supported profiles are available in the Server Object under ServerCapabilities.ServerProfileArray
Table 45 lists all Profiles defined in this document and defines their URIs.
Table 45 - Profile URIs for OPC 40082-6
18.2.2 Server Facets18.2.2.1 OverviewThe following sections specify the Facets available for Servers that implement the OPC 40082-6 companion specification. Each section defines and describes a Facet or Profile .
18.2.2.2 OPC 40082-6 Basic Server Profile
Table 46 - OPC 40082-6 Basic Server Profile
Group
Conformance Unit / Profile Title
Mandatory / Optional
Profile 0:Embedded Server 2017 (defined in OPC 10000-7) M Profile 0:ComplexType Server Facet (defined in OPC 10000-7) M Profile 0:Standard Event Subscription Server Facet (defined in OPC 10000-7) M Profile 0:Method Server Facet (defined in OPC 10000-7) M Profile 2:BaseDevice Server Facet (defined in OPC 10000-100) M Profile 3:Machinery Machine Identification Server Facet M Profile 3:Machinery State Server Facet M Profile 0:A & C Alarm Server Facet M OPC 40082-6 OPC 40082-6 Basic M
18.2.2.3 DesiccantBedDryer Server Facet
Table 47: OPC 40082-6 DesiccantBedDryer Server Facet
Group
Conformance Unit / Profile Title
Mandatory / Optional
OPC 40082-6 OPC 40082-6 Basic M OPC 40082-6 OPC 40082-6 DesiccantBed M
18.2.2.4 Full Server Facet
Table 48: OPC 40082-6 Full Server Facet
Group
Conformance Unit / Profile Title
Mandatory / Optional
OPC 40082-6 OPC 40082-6 Basic M OPC 40082-6 OPC 40082-6 Maintenance O OPC 40082-6 OPC 40082-6 Users O OPC 40082-6 OPC 40082-6 DryingProtection O OPC 40082-6 OPC 40082-6 AllFeeders O OPC 40082-6 OPC 40082-6 MaterialFeeder O OPC 40082-6 OPC 40082-6 MachineFeeder O OPC 40082-6 OPC 40082-6 TemperatureController O OPC 40082-6 OPC 40082-6 AirFlowInterval O OPC 40082-6 OPC 40082-6 ResetDryingTime O OPC 40082-6 OPC 40082-6 DesiccantBedController O OPC 40082-6 OPC 40082-6 MaterialIdentification O OPC 40082-6 OPC 40082-6 BatchNumber O OPC 40082-6 OPC 40082-6 MaterialDryingTime O OPC 40082-6 OPC 40082-6 RemainingMaterialDryingTime O OPC 40082-6 OPC 40082-6 DisplayLanguage O OPC 40082-6 OPC 40082-6 IdentifyDevice O OPC 40082-6 OPC 40082-6 ResetAllErrors O OPC 40082-6 OPC 40082-6 ResetErrorById O OPC 40082-6 OPC 40082-6 ResetEnergyMeasurement O OPC 40082-6 OPC 40082-6 MainFailureBehaviour O OPC 40082-6 OPC 40082-6 TotalEnergy O OPC 40082-6 OPC 40082-6 EnergyConsumptionResettable O OPC 40082-6 OPC 40082-6 MaintenanceInformation O OPC 40082-6 OPC 40082-6 EnergyConsumptionLimit O OPC 40082-6 OPC 40082-6 DewPoint O OPC 40082-6 OPC 40082-6 AirFlow O OPC 40082-6 OPC 40082-6 TemperatureOfDesiccantBed O OPC 40082-6 OPC 40082-6 TemperatureDesiccantBedOut O OPC 40082-6 OPC 40082-6 TemperatureBackToDesiccantBed O OPC 40082-6 OPC 40082-6 ExpiredDryingTime O OPC 40082-6 OPC 40082-6 TemperatureReduction O OPC 40082-6 OPC 40082-6 MaterialAvailableDryer O OPC 40082-6 OPC 40082-6 MaterialAvailableMachine O OPC 40082-6 OPC 40082-6 DustRemovalPulses O OPC 40082-6 OPC 40082-6 DryingLevel O OPC 40082-6 OPC 40082-6 AirFlowMode O OPC 40082-6 OPC 40082-6 IntervalTimeOn O OPC 40082-6 OPC 40082-6 IntervalTimeOff O OPC 40082-6 OPC 40082-6 InitialFillingActive O OPC 40082-6 OPC 40082-6 ResetDryingTime O OPC 40082-6 OPC 40082-6 AirSource O OPC 40082-6 OPC 40082-6 TotalAirConsumption O OPC 40082-6 OPC 40082-6 DryAirTemperature O OPC 40082-6 OPC 40082-6 AmbientAirTemperature O OPC 40082-6 OPC 40082-6 TopTemperature O OPC 40082-6 OPC 40082-6 ConeTemperature O OPC 40082-6 OPC 40082-6 CylinderTemperature O OPC 40082-6 OPC 40082-6 LooseningAid O OPC 40082-6 OPC 40082-6 MaintenanceInstructions O OPC 40082-6 OPC 40082-6 RemainingInterval O