20 result(s) for process values
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety3.1.2.8 process valuesprocess values input and output data (in a safety PDU) that are required to control an automated process
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety5.3 Safety measuresSafetyConsumer is defined in such a way that it will cease to deliver actual process values to the safety application but will deliver fail-safe substitute values instead. In addition
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetyfail-safe substitute values are delivered to the safety application instead of the received process values . In contrast, it is not necessary for a SafetyProvider to know the SafetyConsumerID ... SafetyConsumer and will provide its process values to any SafetyConsumer requesting it. SafetyProviders can not detect communication errors. All required error detection is performed by the SafetyConsumer
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.3.2 SAPI of SafetyProviderused to trigger a return from fail-safe substitute values ( FSV ) to actual process values ( PV ), see B.3.4 . OperatorAckRequested Boolean O Indicates that an operator acknowledge is requested ... instead of PV to the safety application program. NOTE If the replacement of process values by FSV is to be controllable in a more fine-grained way, this
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety6.3.4.2 SAPI of SafetyConsumerSafetyConsumer SAPI Term Type I/O Definition SafetyData Structure O This output either delivers the process values received from the SafetyProvider in the SPDU field SafetyData , or FSV . NonSafetyData Structure ... This output delivers the non-safety process values (e.g. diagnostic information) which were sent together with safe data, see 7.2.1.11 Enable Boolean I By changing this input
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetyassumption is still valid, and switches to fail-safe substitute values otherwise. Returning to process values then requires an operator acknowledgment. Operator Acknowledge is expected to be initiated
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetyparameter determines whether automatic restart (i.e. automatically switching back from fail-safe values to process values ) is possible for the safety function or not. It is expected
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safety7.2.1.5 ResponseSPDU: SafetyDatacontain qualifiers for a fine-grained activation of fail-safe substitute values. For valid process values , the respective qualifiers are set to 1 (good), whereas the value ... used for invalid values. Invalid process values are replaced by fail-safe substitute values in the SafetyConsumer 's safety application
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetyshall answer all requests. The returned ResponseSPDUs may contain different values (e.g. currently available process values ) or contain the initially returned values. [RQ7.11] For each SafetyProvider , the implemented choice ... behaviour according to RQ7.10 (i.e. whether currently available process values or initially returned values will be used) shall be documented in the corresponding safety manual. NOTE 2 Since a SafetyConsumer
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetybidirectional connection. Both sides will cease delivering fail-safe values and continue sending process values . This is accomplished by connecting OperatorAckProvider with OperatorAckConsumer at the SafetyConsumer of controller B. Activating
-
OPC-10000-15 – OPC Unified Architecture - Part 15: Safetybidirectional connection. Both sides will cease delivering fail-safe values and continue sending process values . This is accomplished by the logic circuits shown in the safety applications
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serializationshows a Channel Group containing two output channel Objects , a configuration Object and Process Values . Figure 4 - RIO Channel Group From the Clients' perspective, certain use cases when accessing ... single subtrees are supported by the Server . A Client might be interested in the Process Values provided in the "Values" array and the associated Process Value Qualifiers
-
OPC-30142 – OPC UA for PROFINET Remote IO3.2.1 ControllerController A Controller is a host running a program which reads and writes the Process Values used to control an automated process. The control is usually done in cycles consisting
-
OPC-30142 – OPC UA for PROFINET Remote IOwith continuously refined methods and algorithms to identify the potential for economic improvements. Providing Process Values as components of RIO Channel Objects and/or Process Value arrays or bit fields
-
OPC-30142 – OPC UA for PROFINET Remote IOFigure 8 contains an analog Process Value . The VariableType used to represent analog Process Values is RioPaAnalogProcessValueVariableType , the data type used by this VariableType is RioPaAnalogProcessValueDataType . Configuration properties ... Input Channels according to RIOforPA is RioPaAnalogInputConfigVariableType . Figure 9 shows all RIO Channel ObjectTypes , Process Value VariableTypes and configuration ObjectTypes which are defined in this specification to cover digital
-
OPC-30142 – OPC UA for PROFINET Remote IOanalog Input according to RIOforPA to illustrate the relationship between the different aspects. The Process Values and their qualifiers are transmitted consecutively and are available for the user program ... Value" and "03_AI_2_Value" representing the Process Values in the PnIoTelegramType Object "Input" connect to the "ProcessValue" Variables which are components
-
OPC-30142 – OPC UA for PROFINET Remote IOProcess Value Qualifier and StatusCode Relationship When returning the Value of Process Values , the Server shall set the StatusCode member of the DataValue structures returned by the Read Service
-
OPC-30142 – OPC UA for PROFINET Remote IOStatusCode of Arrays of Process Values When returning arrays of Process Values , the Server shall set the Severity of the StatusCode to "Bad" if one or more Process ... Severity returned shall be "Uncertain" if one or more Process Values in the returned array are "Uncertain". The Severity returned shall be "Good" only
-
OPC-30142 – OPC UA for PROFINET Remote IOdifferent VariableTypes together with their DataTypes defined for each profile for digital and analog Process Values . Table 62 - RIO Process Value VariableTypes and DataTypes Profile Digital Channel Types Process Value
-
OPC-30142 – OPC UA for PROFINET Remote IOthis ReferenceType is to connect RioChannelGroup Objects with bit field and array Variables containing Process Values . The HasRioProcessVariable Reference is formally defined in Table 133 . Table 133 - HasRioProcessVariable Definition Attributes ... References NodeClass BrowseName Comment Subtype of HasComponent from OPC 10000-5 . Conformance Units PNRIO Process Variables