OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model3.1.7 DataVariableDataVariable Variables that represent values of Objects , either directly or indirectly for complex Variables , where the Variables are always the TargetNode of a HasComponent Reference
-
OPC-10000-3 – OPC Unified Architecture - Part 3: Address Space Model4.5.1 GeneralGeneral Variables are used to represent values . Two types of Variables are defined, Properties and DataVariables . They differ in the kind of data that they represent and whether they
-
OPC-10000-4 – OPC Unified Architecture - Part 4: ServicesB.2.5 QueryDataSetNode description. typeDefinitionNode ExpandedNodeId The NodeId for the type definition for this Node description. values [] BaseDataType Values for the selected Attributes. The order of returned items matches the order ... were specified using a relative path from the selected instance's TypeDefinitionNode . If no values where found for a given requested item a null value is returned for that item
-
OPC-10000-6 – OPC Unified Architecture - Part 6: Mappings5.1.9 VariantStatusCode and table of strings. As a result, Variants cannot contain instances of DiagnosticInfo. Values of Attributes are always returned in instances of DataValues . Therefore, the DataType of an Attribute
-
OPC-10000-6 – OPC Unified Architecture - Part 6: MappingsF.15 Exampleused for any NodeId value in the document except for NodeIds that appear in Values of Variables or VariableTypes . <Aliases> <Alias Alias="HasComponent
-
OPC-10000-9 – OPC Unified Architecture - Part 9: Alarms & Conditions5.8.2 AlarmConditionTypeprovided. In some systems, an Alarm may be calculated based on multiple Variables Values ; it is up to the system to determine which Variable's NodeId is used. SuppressedState , OutOfServiceState
-
OPC-10000-23 – OPC Unified Architecture - Part 23: Common ReferenceTypes5.1 OverviewReferences are described by a ReferenceDescription , that is, the Variables SomeReferenceType1 and SomeReferenceType2. The Values of those Variables uniquely identify the References by providing SourceNode , TargetNode , ReferenceType and direction
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serialization3.1.5 SerializationValueSerializationValue the merged compact aggregation of the Values of all serialized Nodes belonging to the SerializationScope and is the Value of the SerializedData Variable
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serialization3.1.8 SerializationProcessSerializationProcess the mapping of the SerializationValue from and to the Values in the SerializationScope . Note 1 to entry: This can imply the creation or re-creation of the SerializationFieldDataType used
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationBasic Concept Object Serialization is understood in this specification as the aggregation of the Values of different Variables belonging to a subset of the Information Model ( SerializationScope ) into the Value ... SerializationValue) of a single Variable ( SerializedData ) . Clients gain access to all Values in the SerializationScope at once by accessing the SerializationValue
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationValue of the SerializedData Variable. The DataType of the SerializationValue maps all Values of the Variables in the SerializationScope (see Figure 3 ). The SerializationProperties are provided by the SerializationEntity ... referenced using certain ReferenceTypes , limiting the depth of the SerializationScope and settings which companion values like statusCodes shall be part of the SerializationFieldDataType of Variables is also possible
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serialization4.5 General Featurespreserved. Servers can provide different serializations by providing different SerializationEntities , e.g. for process values or for configuration data as shown in Figure 4 . Different SerializationScopes defined on the same data ... SerializationValue with NonatomicWrite flag set to 0, the update of the original Values in the SerializationScope is like a transaction. This means if update of one original Values fails
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serializationshows a Channel Group containing two output channel Objects , a configuration Object and Process Values . Figure 4 - RIO Channel Group From the Clients' perspective, certain use cases when accessing ... subtrees are supported by the Server . A Client might be interested in the Process Values provided in the "Values" array and the associated Process Value Qualifiers
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serialization6.1 OverviewOverview Object Serialization provides a consistent, compact representation of the Variable Values in the SerializationScope . Objects or Variables that are the root of such a serialization are called SerializationStartNodes ... this ObjectType. The DataType of the SerializedData Variable is the SerializationValue DataType mapping all Values in the SerializationScope . It is the serialization DataType of the SerializationStartNode . The Values themselves each
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationDataSetMetaData (see OPC 10000-14 ). The field names from the structures containing the Values the semantic Properties belong to are qualified with the OPC UA Namespace . This allows the encoder ... CustomMetaDataProperties Property of the SerializedData Variable describes the semantic Properties for all Values mapped into the SerializationValue DataType of the SerializedData . It is used as Properties field of the FieldMetaData
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object Serializationthis DataType is serialized by the JSON encoder. If the SerializationProperties have default values, the Properties of the ChannelGroupConfig Object (see OPC RIO) are mapped into fields of the SerializationValue ... JSON encoding of this structure only contains the field names as keys and the Values of the serialized fields as JSON literals when using VerboseEncoding
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationChannel Process Values Figure A.3 shows how Process Values (see OPC RIO) belonging to RioChannelType Objects are mapped into the SerializationValue DataType . The "SerializationEntity" referenced by the SerializationStartNode ... subtrees originating from the Channel Objects . The JSON snipped shows how the Values in the SerializationScope are serialized using VerboseEncoding (see OPC 10000-6 ) and RawData field encoding
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationEnergy Measurement Values Figure A.4 shows a SerializationScope configured to exclude the metadata Properties of the Objects and Variables reachable from the SerializationStartNode . The EnergyMeasurementType Object has a mandatory PeObjectNumber ... MeasurementValueType Variables (see OPC PE ) The SerializationValue DataType structure contains only fields for the Values of the MeasurementValueType Variables . The JSON snipped shows how the energy data in the SerializationScope
-
OPC-10000-25 – OPC Unified Architecture - Part 25: Object SerializationStatusCode of the "MeasurementX1", "MeasurementX2" and "MeasurementXn" Variable Values is never encoded into JSON. Figure A.7 - Combining Serialization Scopes
-
OPC-10000-81 – OPC Unified Architecture - Part 81: UAFX Connecting Devices and Information ModelE.4.7 PubSub DataSetshave a value that is returned in every message. The message only contains the values, so the Subscriber has to be aware of the order/mapping of Variables in the DataSet ... delta frame, which is very similar to Client Server communication, and only changed values are sent. In this type of DataSetMessage , an index and the value are packaged into
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devicesmanufacturer point of view. They can be used as part of the identification. The Values of these Properties are typically provided by the component vendor. The VendorNameplate Interface is illustrated
-
OPC-10000-100 – OPC Unified Architecture - Part 100: Devices8.7.3 Package metadatasoftware package False PackageType 2:PackageType Type of the Software Package . Other values are reserved for future use. False SoftwareSubClass 0:String Name of the application (in case of SoftwareClass ... Identification functional group or its parent device or an application on that device… False Values[] 0:BaseDataType Comparison values (zero, one or more values depending on the comparison operator
-
OPC-10000-110 – OPC Unified Architecture - Part 110: Asset Management Basics13.3.1 Overviewboth information sources in sync, especially when the Property is writable. Servers may reject Values not represented by Objects or may extend the Locations hierarchy