OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsremote invocable Methods . Furthermore, it shall organize at least the CurrentValue and TargetValue Properties found in the ParameterSet Object . Additional references to Properties or Methods within the scope of this
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basicsdefined in 7.6.1 0:HasComponent Variable CurrentValue 0:Double AnalogUnitRangeType M 0:HasComponent Variable TargetValue 0:Double AnalogUnitRangeType M Conformance Units LADS AnalogControlFunctionType CurrentValue is the current process value. TargetValue
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsObjectType Definition The AnalogControlFunctionWithComposedTargetValueType describes an analogue control function (using analogue values), but the TargetValue is composed of several partial values. An example of a composed target value used ... base value with periodically changing values for defined amplitude, frequency, and waveform. As the TargetValue is calculated from variables in the TargetValueSet , it should be read-only. The AnalogControlFunctionWithComposedTargetValueType
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: Basics7.6.7.2 ModifyTargetValueByModifyTargetValueBy The ModifyTargetValueBy Method is used to modify the current TargetValue by a relative amount. The resulting value shall be limited to the TargetValue's allowed range (EURange). The direction
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsHasComponent Variable CurrentValue 0:Double 0:AnalogUnitRangeType M, R 0:HasComponent Variable TargetValue 0:Double 0:AnalogUnitRangeType M, RW Conformance Units LADS ControllerParameterType AlarmMonitor indicates whether the deviation from ... limit. See: 10000-9: Alarms & Conditions | ExclusiveDeviationAlarmType. CurrentValue is the current process value. TargetValue is the targeted set-point value
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsBaseControlFunctionType defined in 7.6.1 0:HasComponent Variable CurrentValue BaseDataType DiscreteItemType M 0:HasComponent Variable TargetValue BaseDataType DiscreteItemType M Conformance Units LADS DiscreteControlFunctionType CurrentValue is a current discrete process value. TargetValue
-
OPC-30500-1 – OPC UA for Laboratory & Analytical Device Standard (LADS) - Part 1: BasicsTable 117 . Once started, the CurrentValue counts upwards from zero until it reaches the TargetValue . The DifferenceValue is calculated by subtracting the CurrentValue from the TargetValue . Thus, it counts downwards ... from the TargetValue to zero. As soon as the CurrentValue reaches the TargetValue , the CurrentState of the TimerFunction automatically transitions to Off. This is typically accompanied by some (internal) action/effect
-
OPC-40200 – OPC UA for Weighing Technology7.34.3 ObjectType DescriptionObjectType Description TargetValue defines the value to be reached of an aggregate that is referenced by TargetValueId . TargetValueId defines a unique ID of the aggregate that is being activated
-
OPC-40200 – OPC UA for Weighing Technology7.43.3 ObjectType DescriptionObjectType Description TargetValue defines the preset of the volume to be processed. TipCounter defines the number of fillings (downpour, bulk produce