Search
8 result(s) for SEM
-
OPC-30020 – MDIS OPC UA Companion Specification6.6.5 Choke Step MethodStep ( [in] ChokeCommandEnum Direction, [in] 0:UInt16 Steps, [in] 0:Boolean OverrideInterlocks, [in] SEMEnum SEM); Table 43 - Step Method Arguments (Choke) Argument Description Direction Enumeration to indicate if an open ... OverrideInterlocks Boolean indicating if the open or close command should override any defeatable interlocks SEM The selection of which SEM to send the command to. Method result codes are defined
-
OPC-30020 – MDIS OPC UA Companion Specification6.8.4 Valve Move Methodclose a valve. Signature Move ( [in] CommandEnum Direction, [in] 0:Boolean OverrideInterlock, [in] SEMEnum SEM, [in] 0:Boolean Signature, [in] 0:Boolean ShutdownRequest); Table 54 - Move Arguments (Valve) Argument Description ... OverrideInterlock Boolean indicating if the open or close command should override any defeatable interlocks SEM The enumeration indicates which SEM to send the command to. Signature Boolean indicating
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.4 SetOperationMode Methodchange the operation mode of the CIMV. Signature SetOperationMode ( [in] CIMVOperationModeEnum Mode, [in] SEMEnum SEM, [in] 0:Boolean ShutdownRequest); Table 60 - SetOperationMode Method Arguments Argument Description Mode Enumeration indicating ... requested operation mode SEM The selection of which SEM to send the command to ShutdownRequest Boolean indicates that this command is part of a shutdown sequence. Method result codes
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.5 SetFlowRate Methodtarget flow rate. Signature SetFlowRate ( [in] 0:Float FlowRate, [in] SEMEnum SEM, [in] 0:Boolean ShutdownRequest); Table 62 - SetFlowRate Method Arguments Argument Description FlowRate Target flow rate. The CIMV will ... automatically maintain this target flow SEM The selection of which SEM to send the command to ShutdownRequest Boolean indicates that this command is part of a shutdown sequence. Method result
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.6 SetPosition Methodused to set a target position. Signature SetPosition ( [in] 0:Float Position, [in] SEMEnum SEM [in] 0:Boolean ShutdownRequest); Table 64 - SetPosition Method Arguments Argument Description Position Target position ... percent of open. The CIMV will automatically maintain this position SEM The selection of which SEM to send the command to ShutdownRequest Boolean indicates that this command is part
-
OPC-30020 – MDIS OPC UA Companion Specification6.9.7 SetManual Methodopen position. Signature: SetManual ( [in] CIMVMoveEnum Direction, [in] 0:Float Delta, [in] SEMEnum SEM, [in] 0:Boolean ShutdownRequest); Table 66 - SetManual Method Arguments Argument Description Direction Direction to move - Open ... delta is 5% and the direction is open , the result will be 55%) SEM The selection of which SEM to send the command to ShutdownRequest Boolean indicates that this command
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.2 ServerMove Method for basic functionality. The Move Method basic functionality includes Direction , OverrideInterlocks , SEM and ShutdownRequest . Server MDIS Valve SignatureRequestStatus Supports providing information about an existing signature/profile requests, including ... Method ), Abort Method ( ChokeAbort Method ), The Move Method basic functionality includes Position , OverrideInterlocks and SEM . The SetCalculatedPosition Method basic functionality includes CalculatedPosition and if required the SetCalculatedPositionStatus Server MDIS Choke
-
OPC-30020 – MDIS OPC UA Companion Specification14.2.3 ClientMove Method for basic functionality. The Move Method basic functionality includes Direction , OverrideInterlocks , SEM and ShutdownRequest . Client MDIS Valve Client CommandRejected Makes use of CommandRejected. Client MDIS Valve Client SignatureRequestStatus ... ChokeMoveMethod ), Abort ( ChokeAbortMethod ), SetCalculatedPosition ( ChokeSetCalculatedPositionMethod ). The Move Method basic functionality includes Position , OverrideInterlocks and SEM, The SetCalculatedPosition Method basic functionality includes CalculatedPosition and if required the SetCalculatePositionStatus. Client MDIS Choke